Wash. Admin. Code § 296-307-28060

Current through Register Vol. 24-23, December 1, 2024
Section 296-307-28060 - Materials used for guardrails and toeboards
(1) A guardrail used to guard power transmission parts must be 42 inches tall, with a midrail between the top rail and the floor.
(2) Posts must be 8 feet apart or less. They must be permanent and substantial, smooth, and free from protruding nails, bolts, and splinters. If made of pipe, the post must be at least 1-1/4 inches inside diameter. If posts are made of metal shapes or bars, the section must be as strong as posts made of 1-1/2 by 1-1/2 by 3/16-inch angle iron. If posts are made of wood, the posts must be at least 2 by 4 inches. The upper rail must be 2 by 4 inches, or two 1 by 4 inch strips, one at the top and one at the side of the posts. The midrail must be at least 1 by 4 inches.
(3) The rails (metal shapes, metal bars, or wood), should be on the side of the posts that gives the best protection and support. Where panels are fitted with expanded metal or wire mesh (as noted in Table 1) the middle rails may be omitted. Where guard is exposed to contact with moving equipment, additional strength may be necessary.
(4) Toeboards must be at least 4 inches tall, of wood, metal, or metal grill of a maximum 1-inch mesh. Toeboards at flywheel pits should be placed as close to edge of the pit as possible.

Table P-1

TABLE OF STANDARD MATERIALS AND DIMENSIONS

Material

Clearance from moving part at all points (inches)

Largest mesh or opening allowable (inches)

Minimum gauge (U.S. Standard) or thickness (inches)

Minimum height of guard from floor or platform level (feet)

Woven wire

Under 2

2-4

Under 4

4-15

3/8

1/2

1/2 2

No. 16

No. 16

No. 16

No. 12

7

7

7

7

Expanded metal

Under 4

4-15

1/2

2

No. 18

No. 13

7

7

Perforated metal

Under 4

4-15

1/2

2

No. 20

No. 14

7

7

Sheet metal

Under 4

4-15

No. 22

No. 22

7

7

Wood or metal strip crossed

Under 4

4-15

3/8

2

Wood 3/4

Metal No. 16

Wood 3/4

Metal No. 16

7

7

Wood or metal strip not crossed

Under 4

4-15

1/2 width

1 width

Wood 3/4

Metal No. 16

Wood 3/4

Metal No. 16

7

7

Standard rail

Min. 15 Max. 20

Table P-2

HORIZONTAL OVERHEAD BELTS, ROPES, AND CHAINS 7 FEET OR MORE ABOVE FLOOR OR PLATFORM

Width 0"-14" inclusive

Material

MEMBERS

Framework

1 1/2" x 1 1/2" x 1/4"

Angle iron

Filler (belt guards)

1 1/2" x 3/16"

Flat iron

Filler and vertical side member

No. 20 A.W.G.

Solid sheet metal

Filler supports

2" x 5/16" flat iron

Flat and angle

Guard supports

2" x 5/16"

Flat iron

FASTENINGS

Filler supports to framework

(2) 3/16"

Rivets

Filler flats to supports (belt guards)

(1) 5/16"

Flush rivets

Filler to frame and supports (chain guards)

3/16"

Rivets spaced

Guard supports to framework

(2) 3/6"

Rivets or bolts

Guard and supports to overheard ceiling

1/4" x 3 1/2" lag screws or 1/2" bolts

Lag screws or bolts

DETAILS-SPACING, ETC.

Width of guards

Spacing between filler supports

Spacing between filler flats (belt guards)

One-quarter wider than belt, rope, or chain drive

20" center to center

2" apart

Width 0"-14" inclusive

Material

Spacing between guard supports

36" center to center

OTHER BELT GUARD FILLING PERMITTED

Sheet metal fastened as in chain guards

Woven Wire, 2" mesh

No. 20 A.W.G.

No. 12 A.W.G.

Solid or perforated

CLEARANCE FROM OUTSIDE OF BELT, ROPE, OR CHAIN DRIVE TO GUARD

Distance center to center of shafts

Up to 15' inclusive

Over 40'

Clearance from belt, or chain to guard

16"

120"

Width over 14" to 24" inclusive

Material

MEMBERS

Framework

2" x 2" x 5/16"

Angle iron

Filler (belt guards)

2" x 3/16"

Flat iron

Filler and vertical side member

No. 18 A.W.G.

Solid sheet metal

Filler supports

2" x 3/8" flat iron

Flat and angle

Guard supports

2" x 3/8"

Flat iron

FASTENINGS

Filler supports to framework

(2) 3/6"

Rivets

Filler flats to supports (belt guards)

(1) 5/16"

Flush rivets

Filler to frame and supports (chain guards)

8" centers on sides and 4" centers on bottom

Guard supports to framework

(2) 7/16"

Rivets or bolts

Guard and supports to overheard ceiling

5/8" x 4" lag screws or 5/8" bolts

Lag screws or bolts

DETAILS-SPACING, ETC.

Width of guards

Spacing between filler supports

16" C. to C

Spacing between filler flats (belt guards)

2 1/2" apart

Spacing between guard supports

36" C. to C

OTHER BELT GUARD FILLING PERMITTED

Sheet metal fastened as in chain guards

No. 18 A.W.G.

Solid or perforated

Woven wire, 2" mesh

No. 10 A.W.G.

CLEARANCE FROM OUTSIDE OF BELT, ROPE, OR CHAIN DRIVE TO GUARD

Distance center to center of shafts

Over 15' to 25'

Over 40' inclusive

Clearance from belt/chain to guard

10"

20"

Width over 24"

Material

MEMBERS

Framework

3" x 3" x 3/8"

Angle iron

Filler (belt guards)

2" x 5/16"

Flat iron

Filler and vertical side member

No. A.W.G.

Solid sheet metal

Filler supports

2 1/2" x 2 1/2" x 1/4" angle

Flat and angle

Guard supports

2 1/2" x 3/8"

Flat iron

FASTENINGS

Filler supports to framework

(3) 1/2"

Rivets

Filler flats to supports (belt guards)

(2) 3/8"

Flush rivets

Filler to frame and supports (chain guards)

Width 0"-14" inclusive

Material

Guard supports to frame work Guard and supports to overhead ceiling

(2) 5/8" 3/4" x 6" lag screws or 3/4" bolt

Rivets or bolts Lag screws or bolts

DETAILS-SPACING, ETC.

Width of guards

Spacing between filler supports

16" C. to C.

Spacing between filler flats (belt guards)

4" apart

Spacing between guard supports

36" C. to C.

OTHER BELT GUARD FILLING PERMITTED

Sheet metal fastened as in chain guards

No. 18 A.W.G.

Solid or perforated

Woven wire, 2" mesh

No. 8 A.W.G.

CLEARANCE FROM OUTSIDE OF BELT, ROPE, OR CHAIN DRIVE TO GUARD

Distance center to center of shafts

Over 25' to 40' inclusive

Over 40'

Clearance from belt, or chain to guard

15"

20"

Wash. Admin. Code § 296-307-28060

Amended by WSR 20-21-091, Filed 10/20/2020, effective 11/20/2020

Statutory Authority: RCW 49.17.040. 98-24-096, § 296-307-28060, filed 12/1/98, effective 3/1/99. 97-09-013, recodified as § 296-307-28060, filed 4/7/97, effective 4/7/97. Statutory Authority: RCW 49.17.040, [49.17.]050 and[49.17.]060 . 96-22-048, § 296-306A-28060, filed 10/31/96, effective 12/1/96.