Section 296-307-26024 - Requirements that apply to stair treads
(1) When risers are used, each tread and the top landing of a stairway should have a nose extending 1/2 to one inch beyond the face of the lower riser.
(2) Noses should have an even leading edge.
(3) All treads must be reasonably slip-resistant and the nosings must be of nonslip finish. Welded bar grating treads without nosings are acceptable if the leading edge can easily be identified by employees descending the stairway and the tread is serrated or is nonslip.
(4) Rise height and tread width must be uniform throughout any flight of stairs including any foundation structure used as one or more treads of the stairs.

Wash. Admin. Code § 296-307-26024

Amended by WSR 21-04-128, Filed 2/2/2021, effective 3/8/2021

97-09-013, recodified as § 296-307-26024, filed 4/7/97, effective 4/7/97. Statutory Authority: RCW 49.17.040,[49.17.]050 and [49.17.]060. 96-22-048, § 296-306A-26024, filed 10/31/96, effective 12/1/96.