Wash. Admin. Code § 296-307-25030

Current through Register Vol. 24-23, December 1, 2024
Section 296-307-25030 - Requirements that apply to toeboards
(1) Standard toeboard height is at least four inches nominal from its top edge to the level of the floor, platform, runway, or ramp. The toeboard must be securely fastened in place and with a maximum of 1/4 inch clearance above floor level. It must be made of any substantial material that is either solid or with openings that are a maximum of one inch in diameter.
(2) Where material is piled high enough that a standard toeboard does not provide protection, paneling from the floor to the intermediate rail, or to the top rail, must be provided.

Wash. Admin. Code § 296-307-25030

Amended by WSR 21-04-128, Filed 2/2/2021, effective 3/8/2021

97-09-013, recodified as § 296-307-25030, filed 4/7/97, effective 4/7/97. Statutory Authority: RCW 49.17.040,[49.17.]050 and [49.17.]060. 96-22-048, § 296-306A-25030, filed 10/31/96, effective 12/1/96.