Table F-2 Minimum Lighting Intensities in Foot-Candles
Lumens (foot-candles) | Area or operation |
3 | General areas on vessels and vessel sections such as accessways, exits, gangways, stairs, and walkways. |
5 | General landside areas such as corridors, exits, stairs, and walkways. |
5 | All assigned work areas on any vessel or vessel section. |
5 | Landside tunnels, shafts, vaults, pumping stations, and underground work areas. |
10 | Landside work areas such as machine shops, electrical equipment rooms, carpenter shops, lofts, tool rooms, warehouses, and outdoor work areas. |
10 | Changing rooms, showers, sewered toilets, and eating, drinking, and break areas. |
30 | First-aid stations, infirmaries, and offices. |
Note to Table F-2: The required illumination levels in this table do not apply to emergency or portable lights.
Wash. Admin. Code § 296-304-06003
Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060, and chapter 49.17 RCW. 12-12-060, § 296-304-06003, filed 6/5/12, effective 8/1/12. Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. 03-04-099, § 296-304-06003, filed 2/4/03, effective 8/1/03; Order 74-25, § 296-304-06003, filed 5/7/74.