Note to (2)(c)(i): | Spaces containing highly volatile residues may require additional ventilation to keep the concentration of flammable vapors below 10 percent of the lower explosive limit and within the permissible exposure limit. |
Note to (2)(d): | See WAC 296-304-02013 Appendix B, for additional information on frequency of testing. |
Exception: An employee may enter for emergency rescue or for a short duration for installation of ventilation equipment provided:
Note to (2)(f): | Other provisions for work in IDLH and other dangerous atmospheres are located in WAC 296-304-090 through 296-304-09007. |
Note to (2)(i): | Battery-fed, portable lamps or other electric equipment bearing the approval of a NRTL for the class, and division of the location in which they are used are deemed to meet the requirements of (i) of this subsection. |
Note to (2): | See WAC 296-304-02003(3) and applicable requirements of chapter 296-62 WAC, general occupational health standards, for other provisions affecting cleaning and cold work. |
Wash. Admin. Code § 296-304-02005
Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 07-17-034, § 296-304-02005, filed 8/7/07, effective 12/1/07. Statutory Authority: Chapter 49.17 RCW. 95-04-006, § 296-304-02005, filed 1/18/95, effective 3/10/95; Order 74-25, § 296-304-02005, filed 5/7/74.