Wash. Admin. Code § 246-215-04405

Current through Register Vol. 24-23, December 1, 2024
Section 246-215-04405 - Installation-Fixed equipment, spacing or sealing (FDA Food Code 4-402.11)
(1) EQUIPMENT that is fixed because it is not EASILY MOVABLE must be installed so that it is:
(a) Spaced to allow access for cleaning along the sides, behind, and above the EQUIPMENT;
(b) Spaced from adjoining EQUIPMENT, walls, and ceilings a distance of not more than one thirty-second inch (1 mm); or
(c) SEALED to adjoining EQUIPMENT or walls, if the EQUIPMENT is exposed to spilling or seepage.
(2) COUNTER-MOUNTED EQUIPMENT that is not EASILY MOVABLE must be installed to allow cleaning of the EQUIPMENT and areas underneath and around the EQUIPMENT by being:
(a) SEALED; or
(b) Elevated on legs as specified under WAC 246-215-04410.

Wash. Admin. Code § 246-215-04405

Amended by WSR 21-01-122, Filed 12/15/2020, effective 1/15/2021

Statutory Authority: RCW 43.20.050 and 43.20.145. 13-03-109, § 246-215-04405, filed 1/17/13, effective 5/1/13.