Wash. Admin. Code § 246-359-740

Current through Register Vol. 24-23, December 1, 2024
Section 246-359-740 - Drain connector to factory assembled structures (FAS)
(1) A FAS containing plumbing fixtures must be connected to the drain inlet by a drain connector:
(a)Approved by the department of health;
(b) Consisting of pipe not less than Schedule 40 with appropriate fittings and connectors; and
(c)Not less in size than the FAS outlet.
(2) The fitting connected to the drain inlet must be a directional fitting to discharge the flow into the drain inlet.
(3)A drain connector must be:
(a) Installed and maintained with a grade not less than one-fourth inch per foot;
(b)Gas-tight and no longer than necessary to make the direct connection between the mobile home outlet and drain inlet at the site.
(4)Each drain inlet must be maintained gas-tight when not in use.

Wash. Admin. Code § 246-359-740

Amended by WSR 15-13-091, Filed 6/15/2015, effective see below

Statutory Authority: RCW 70.114A.081. 99-03-065, § 246-359-740, filed 1/18/99, effective 2/18/99.