These provisions shall not be construed to limit the actual stack height.
where: Hg = "good engineering practice" (GEP) stack height, measured from the ground level elevation at the base of the stack,
H = height of nearby structure(s) measured from the ground level elevation at the base of the stack,
L = lesser dimension, height or projected width, of nearby structure(s), subject to the proviso below.
"Nearby," as used in this subsection for purposes of applying the GEP formula means that distance up to five times the lesser of the height or the width dimension of a structure, but not greater than 0.8 kilometer (1/2 mile).
Wash. Admin. Code § 173-400-200
Statutory Authority: RCW 70.94.152. 05-03-033 (Order 03-07), § 173-400-200, filed 1/10/05, effective 2/10/05. Statutory Authority: Chapter 70.94 RCW. 91-05-064 (Order 90-06), § 173-400-200, filed 2/19/91, effective 3/22/91.