6 Va. Admin. Code § 15-81-800

Current through Register Vol. 41, No. 8, December 2, 2024
Section 6VAC15-81-800 - Food service
A. If a kitchen is provided, it shall be equipped to meet the standards of the Department of Health and the following:
1. The kitchen and kitchen storage shall be sized in accordance with the design capacity of the facility and include consideration for future expansion.
2. The kitchen area, exclusive of dining and serving areas, shall be a minimum of 1500 square feet and for facilities in excess of 100 inmates of design capacity an additional three square feet per inmate shall be provided. The kitchen shall be located with consideration for ease of serving the inmate population and where supplies can readily be received without breaching security. Space for food storage rooms is in addition to the above minimum square footage.
3. Consideration shall be given to providing an inmate break area within the kitchen area. This shall not reduce the size of the kitchen or other spaces associated with the kitchen.
4. A janitor's closet and mop sink shall be located within the kitchen for exclusive use in the kitchen.
5. Storage space of adequate size and type to accommodate perishable, frozen, and bulk dry food storage shall be provided.
a. For facilities with a design capacity up to 1000 inmates, the storage space shall be sized not less than three square feet of floor space per inmate. For design capacity in excess of 1000, the sizing may be 2.7 square feet of floor space per inmate for the next 800 inmates. Further reductions may be approved for jails with a design capacity of greater than 1800 inmates. Storage space requirements are based on a seven-day supply need. Aggregate kitchen storage space shall be a minimum of 300 square feet of floor space.
b. The following breakdown of storage space is recommended: 40% dry, 36% refrigerated and 24% freezer.
c. Walls for food storage shall extend to the structure above.
6. All kitchen counters and table tops, legs, and bases; shelving; and fixed equipment shall be stainless steel.
7. The floors, walls, and ceilings in the food service areas shall be a smooth durable finish, shall withstand food spillage, and shall be easily cleanable.
8. Adequately sized separate lockable storage shall be provided for caustic, toxic, and flammable kitchen supplies. Secure storage or space for secure storage shall be provided for kitchen inventory of sharp implements and other potential weapons. Consideration shall be given for locating lockable storage in a separate locked room.
9. Provisions shall be made for kitchen waste removal from the kitchen area without crossing the food preparation area.
10. Hand washing sinks for inmate toilets shall be located outside the toilet room and in view of the staff.
11. Consideration shall be given to locating an emergency eye wash station in the kitchen.
12. Consideration shall be given to providing a smoke removal system for the kitchen.
B. In addition to kitchen and kitchen storage areas, a staff dining or break area shall be provided with a minimum of 15 square feet for each person the area is designed to serve. Floors, walls and ceilings shall be a smooth, durable finish and easily cleanable.

6 Va. Admin. Code § 15-81-800

Derived From Virginia Register Volume 34, Issue 12, eff. 3/8/2018.

Statutory Authority: 53.1-5, 53.1-80, and 53.1-82 of the Code of Virginia.