Current through Register Vol. 41, No. 8, December 2, 2024
Section 1VAC30-110-70 - Laboratory analysisA. TEM analysis shall be conducted as described in 40 CFR, Part 763, Subpart E, Appendix A, Unit II.B. PCM analysis shall be conducted using the National Institute for Occupational Safety and Health (NIOSH) Method 7400 entitled "Fibers" published in the NIOSH Manual of Analytical Methods, 3rd Edition, Second Supplement, August 1987.C. The following minimum information must be reported by the analytical laboratory to the client: 1. Concentration in structures per square millimeter (TEM) and structures per cubic centimeter (PCM).2. Analytical sensitivity used for the analysis.3. Number of asbestos structures (TEM).5. Volume of air samples (which was initially provided by client.6. Average grid size opening.7. Number of grids analyzed.8. Copy of the count sheet.10. Signature of laboratory analyst.11. Official laboratory identification.12. Floor plan indicating location where samples were obtained (provided initially by client).13. Copy of asbestos analytical laboratory license.1 Va. Admin. Code § 30-110-70
Derived from VR330-03-02 § 7, eff. August 1, 1974; amended, Virginia Register Volume 9, Issue 21, eff. August 11, 1993.Statutory Authority
§ 2.1-526.14 of the Code of Virginia.