Current through Bulletin 2024-23, December 1, 2024
Section R649-3-25 - Underground Disposal of Drilling Fluids1. Operators shall be permitted to inject and dispose of reserve pit drilling fluids downhole in a well upon submitting an application for such operations to the division and obtaining its approval. Injection of reserve pit fluids shall be considered by the division on a case-by-case basis.2. Each proposed injection procedure will be reviewed by the division for conformance to the requirements and standards for permitting disposal wells under Subsection R649-5-2 to assure protection of fresh-water resources.3. The subsurface disposal interval shall be verified by temperature log, or suitable alternative, during the disposal operation.4. The division shall designate other conditions for disposal, as necessary, in order to ensure safe, efficient fluid disposal.Utah Admin. Code R649-3-25
Amended by Utah State Bulletin Number 2020-15, effective 7/27/2020