The governing body shall ensure that:
TABLE 1 Minimum Required Illumination Levels | |
Area | Footcandle Level |
General instruction, including classroom, study hall, music room, lecture room, handwritten work area, and library. | 35.0 |
Special instruction -- CTE and high-risk areas | 50.0 |
Gymnasium - auxiliary spaces, shower rooms, and locker rooms | 10.0 |
Gymnasium - main recreation spaces | 25.0 |
Auditorium, faculty and staff lunchroom, assembly and multi-purpose room, and similar room not routinely used for instruction | 30.0 |
Corridor, commons, stairs, hallway, indoor passageway, storeroom, and similar areas | 10.0 |
Toilet room | 15.0 |
Office | 35.0 |
Conference room | 30.0 |
Media center | 25.0 |
Building entrances, parking areas, roads, and similar areas | 0.2 |
Utah Admin. Code R392-200-8