Utah Admin. Code 313-25-3

Current through Bulletin 2024-20, October 15, 2024
Section R313-25-3 - Pre-licensing Plan Approval Criteria for Siting of Commercial Radioactive Waste Disposal Facilities
(1) Persons proposing to construct or operate commercial radioactive waste disposal facilities, including waste incinerators, shall obtain a plan approval from the Director before applying for a license. Plans shall meet the siting criteria and plan approval requirements of Section R313-25-3.
(2) The siting criteria and plan approval requirements in Section R313-25-3 apply to prelicensing plan approval applications.
(3) Treatment and disposal facilities, including commercial radioactive waste incinerators, shall not be located:
(a) within or underlain by:
(i) national, state, and county parks, monuments, and recreation areas; designated wilderness and wilderness study areas; wild and scenic river areas;
(ii) ecologically and scientifically significant natural areas, including wildlife management areas and habitats for listed or proposed endangered species as designated by federal law;
(iii) 100 year floodplains;
(iv) areas 200 feet distant from Holocene faults;
(v) underground mines, salt domes and salt beds;
(vi) dam failure flood areas;
(vii) areas subject to landslide, mud flow, or other earth movement, unless adverse impacts can be mitigated;
(viii) farmlands classified or evaluated as "prime", "unique", or of "statewide importance" by the U.S. Department of Agricultural Soil Conservation Service under the Prime Farmland Protection Act;
(ix) areas five miles distant from existing permanent dwellings, residential areas, and other habitable structures, including schools, churches, and historic structures;
(x) areas five miles distant from surface waters including intermittent streams, perennial streams, rivers, lakes, reservoirs, and wetlands;
(xi) areas 1000 feet distant from archeological sites to which adverse impacts cannot reasonably be mitigated;
(xii) recharge zones of aquifers containing ground water which has a total dissolved solids content of less than 10,000 mg/l; or
(xiii) drinking water source protection areas designated by the Utah Drinking Water Board;
(b) in areas:
(i) above or underlain by aquifers containing ground water which has a total dissolved solids content of less than 500 mg/l and which aquifers do not exceed state ground water standards for pollutants;
(ii) above or underlain by aquifers containing ground water which has a total dissolved solids content between 3000 and 10,000 mg/l when the distance from the surface to the ground water is less than 100 ft.;
(iii) areas of extensive withdrawal of water, mineral or energy resources.
(iv) above or underlain by weak and unstable soils, including soils that lose their ability to support foundations as a result of hydrocompaction, expansion, or shrinkage;
(v) above or underlain by karst terrains.
(4) Commercial radioactive waste disposal facilities may not be located within a distance to existing drinking water wells and watersheds for public water supplies of five years ground water travel time plus 1000 feet.
(5) The plan approval siting application shall include hydraulic conductivity and other information necessary to estimate adequately the ground water travel distance.
(6) The plan approval siting application shall include the results of studies adequate to identify the presence of ground water aquifers in the area of the proposed site and to assess the quality of the ground water of all aquifers identified in the area of the proposed site.
(7) Emergency response and safety.
(a) The plan approval siting application shall demonstrate the availability and adequacy of services for on-site emergencies, including medical and fire response. The application shall provide written evidence that the applicant has coordinated on-site emergency response plans with the local emergency planning committee (LEPC).
(b) The plan approval siting application shall include a comprehensive plan for responding to emergencies at the site.
(c) The plan approval siting application shall show proposed routes for transportation of radioactive wastes within the state. The plan approval siting application shall address the transportation means and routes available to evacuate the population at risk in the event of on-site accidents, including spills and fires.
(8) The plan approval siting application shall provide evidence that if the proposed disposal site is on land not owned by state or federal government, that arrangements have been made for assumption of ownership in fee by a state or federal agency.
(9) Siting Authority. The Director recognizes that Titles 10 and 17 of the Utah Code give cities and counties authority for local use planning and zoning. Nothing in Section R313-25-3 precludes cities and counties from establishing additional requirements as provided by applicable state and federal law.

Utah Admin. Code R313-25-3

Amended by Utah State Bulletin Number 2018-9, effective 4/16/2018