Utah Admin. Code 313-22-32

Current through Bulletin 2024-23, December 1, 2024
Section R313-22-32 - Filing Application for Specific Licenses
(1) Applications for specific licenses shall be filed on a form prescribed by the Director.
(2) The Director may, after the filing of the original application, and before the expiration of the license, require further statements in order to enable the Director to determine whether the application should be granted or denied or whether a license should be modified or revoked.
(3) Applications shall be signed by the applicant or licensee or a person duly authorized to act for and on the applicant's behalf.
(4) An application for a license may include a request for a license authorizing one or more activities.
(5) In the application, the applicant may incorporate by reference information contained in previous applications, statements, or reports filed with the Director, provided the references are clear and specific.
(6)
(i) Except as provided in R313-22 (6)(ii), (iii) or (iv) of this section, an application for a specific license to use byproduct material in the form of a sealed source or in a device that contains the sealed source must either---
(A) Identify the source or device by manufacturer and model number as registered with the sealed source and device registry under R313-22-210; or
(B) Contain the information identified in 10 CFR 32.210(c) (January 1, 2015).
(ii) For sources or devices manufactured before October 23, 2012 that are not registered with sealed source and device registry under R313-22-210 and for which the applicant is unable to provide all categories of information specified in 10 CFR 32.210(c) (January 1, 2015), the application must include:
(A) All available information identified in 10 CFR 32.210(c) (January 1, 2015) concerning the source, and, if applicable, the device; and
(B) Sufficient additional information to demonstrate that there is reasonable assurance that the radiation safety properties of the source or device are adequate to protect health and minimize danger to life and property. Such information must include a description of the source or device, a description of radiation safety features, the intended use and associated operating experience, and the results of a recent leak test.
(iii) For sealed sources and devices allowed to be distributed without registration of safety information in accordance with 10 CFR 32.210(g)(1) (2015), the applicant may supply only the manufacturer, model number, and radionuclide and quantity.
(iv) If it is not feasible to identify each sealed source and device individually, the applicant may propose constraints on the number and type of sealed sources and devices to be used and the conditions under which they will be used, in lieu of identifying each sealed source and device.
(7) As provided by Section R313-22-35, certain applications for specific licenses filed under these rules shall contain a proposed decommissioning funding plan or a certification of financial assurance for decommissioning. In the case of renewal applications submitted before January 1, 1995, this submittal may follow the renewal application but shall be submitted on or before January 1, 1995.
(8)
(a) Applications to possess radioactive materials in unsealed form, on foils or plated sources, or sealed in glass in excess of the quantities in Section R313-22-90, "Quantities of Radioactive Materials Requiring Consideration of the Need for an Emergency Plan for Responding to a Release", shall contain either:
(i) An evaluation showing that the maximum dose to a individual off-site due to a release of radioactive materials would not exceed one rem effective dose equivalent or five rems to the thyroid; or
(ii) An emergency plan for responding to a release of radioactive material.
(b) One or more of the following factors may be used to support an evaluation submitted under Subsection R313-22-32(8)(a)(i):
(i) The radioactive material is physically separated so that only a portion could be involved in an accident;
(ii) All or part of the radioactive material is not subject to release during an accident because of the way it is stored or packaged;
(iii) The release fraction in the respirable size range would be lower than the release fraction shown in Section R313-22-90 due to the chemical or physical form of the material;
(iv) The solubility of the radioactive material would reduce the dose received;
(v) Facility design or engineered safety features in the facility would cause the release fraction to be lower than shown in Section R313-22-90;
(vi) Operating restrictions or procedures would prevent a release fraction as large as that shown in Section R313-22-90; or
(vii) Other factors appropriate for the specific facility.
(c) An emergency plan for responding to a release of radioactive material submitted under Subsection R313-22-32(8)(a)(ii) shall include the following information:
(i) Facility description. A brief description of the licensee's facility and area near the site.
(ii) Types of accidents. An identification of each type of radioactive materials accident for which protective actions may be needed.
(iii) Classification of accidents. A classification system for classifying accidents as alerts or site area emergencies.
(iv) Detection of accidents. Identification of the means of detecting each type of accident in a timely manner.
(v) Mitigation of consequences. A brief description of the means and equipment for mitigating the consequences of each type of accident, including those provided to protect workers on-site, and a description of the program for maintaining equipment.
(vi) Assessment of releases. A brief description of the methods and equipment to assess releases of radioactive materials.
(vii) Responsibilities. A brief description of the responsibilities of licensee personnel should an accident occur, including identification of personnel responsible for promptly notifying off-site response organizations and the Director; also responsibilities for developing, maintaining, and updating the plan.
(viii) Notification and coordination. A commitment to and a brief description of the means to promptly notify off-site response organizations and request off-site assistance, including medical assistance for the treatment of contaminated injured on-site workers when appropriate. A control point shall be established. The notification and coordination shall be planned so that unavailability of some personnel, parts of the facility, and some equipment will not prevent the notification and coordination. The licensee shall also commit to notify the Director immediately after notification of the appropriate off-site response organizations and not later than one hour after the licensee declares an emergency.

NOTE: These reporting requirements do not supersede or release licensees of complying with the requirements under the Emergency Planning and Community Right-to-Know Act of 1986, Title III , Public Law 99-499 or other state or federal reporting requirements, including 40 CFR 302, 2010.

(ix) Information to be communicated. A brief description of the types of information on facility status, radioactive releases, and recommended protective actions, if necessary, to be given to off-site response organizations and to the Director.
(x) Training. A brief description of the frequency, performance objectives and plans for the training that the licensee will provide workers on how to respond to an emergency including special instructions and orientation tours the licensee would offer to fire, police, medical and other emergency personnel. The training shall familiarize personnel with site-specific emergency procedures. Also, the training shall thoroughly prepare site personnel for their responsibilities in the event of accident scenarios postulated as most probable for the specific site including the use of team training for the scenarios.
(xi) Safe shutdown. A brief description of the means of restoring the facility to a safe condition after an accident.
(xii) Exercises. Provisions for conducting quarterly communications checks with off-site response organizations and biennial on-site exercises to test response to simulated emergencies. Quarterly communications checks with off-site response organizations shall include the check and update of all necessary telephone numbers. The licensee shall invite off-site response organizations to participate in the biennial exercises. Participation of off-site response organizations in biennial exercises although recommended is not required. Exercises shall use accident scenarios postulated as most probable for the specific site and the scenarios shall not be known to most exercise participants. The licensee shall critique each exercise using individuals not having direct implementation responsibility for the plan. Critiques of exercises shall evaluate the appropriateness of the plan, emergency procedures, facilities, equipment, training of personnel, and overall effectiveness of the response. Deficiencies found by the critiques shall be corrected.
(xiii) Hazardous chemicals. A certification that the applicant has met its responsibilities under the Emergency Planning and Community Right-to-Know Act of 1986, Title III , Public Law 99-499, if applicable to the applicant's activities at the proposed place of use of the radioactive material.
(d) The licensee shall allow the off-site response organizations expected to respond in case of an accident 60 days to comment on the licensee's emergency plan before submitting it to the Director. The licensee shall provide any comments received within the 60 days to the Director with the emergency plan.
(9) An application from a medical facility, educational institution, or Federal facility to produce Positron Emmission Tomography (PET) radioactive drugs for non-commercial transfer to licensees in its consortium authorized for medical use under Rule R313-32 shall include:
(a) A request for authorization for the production of PET radionuclides or evidence of an existing license issued pursuant to 10 CFR Part 30 or equivalent Agreement State requirements for a PET radionuclide production facility within its consortium from which it receives PET radionuclides.
(b) Evidence that the applicant is qualified to produce radioactive drugs for medical use by meeting one of the criteria in Subsection R313-22-75(9)(a)(ii).
(c) Identification of the individual(s) authorized to prepare the PET radioactive drugs if the applicant is a pharmacy, and documentation that each individual meets the requirements of an authorized nuclear pharmacist as specified in Rule R313-32.
(d) Information identified in Subsection R313-22-75(9)(a)(iii) on the PET drugs to be noncommercially transferred to members of its consortium.

Utah Admin. Code R313-22-32

Amended by Utah State Bulletin Number 2015-18, effective 8/26/2015
Amended by Utah State Bulletin Number 2016-13, effective 6/10/2016