Current through Bulletin No. 2024-21, November 1, 2024
Section R307-424-4 - Emission Rates(1) By no later than December 31, 2012, the owner or operator of any EGU with an input heat capacity in excess of 1,500 MMbtu per hour and having commenced operations prior to November 17, 2006, shall demonstrate compliance with at least one of the following: (a) A maximum emission rate of 6.50 X 10-7 pounds mercury per million btu heat input; or(b) A minimum of 90% control of total mercury emissions.(2) Compliance with (1) above shall be based on an annual averaging period beginning January 1 and ending December 31. (a) Beginning January 1, 2013, compliance shall be determined using the monitoring and recordkeeping requirements incorporated under R307-224-2. Upon completion of each year's fourth quarterly report, an assessment shall be made for the entire calendar year and reported to the director within 30 days.(b) Where it is necessary to determine the mercury content of the coal or coals burned, the owner or operator shall use the appropriate ASTM method, and shall measure at least one representative sample each month. Records of such testing shall be kept for a period of at least five years, and shall be made available to the director upon request.(3) Should an EGU be unable to achieve the maximum emission rate or the minimum control efficiency described in (1) above, despite proper operation of the unit in conjunction with a baghouse as well as wet or dry flue gas de-sulfurization, the owner or operator may petition the director for a modification to the compliance limitation for the unit in accordance with R307-401. (a) Such petition shall be received no later than the date upon which the compliance assessment required under (2)(a) above is due.(b) Any such determination by the director will be made on a case-by-case basis, taking into consideration energy, environmental and economic impacts and other costs. It will be based on the best information and analytical techniques available.Utah Admin. Code R307-424-4