Section R307-335-4 - Cold Cleaning FacilitiesNo owner or operator shall operate a degreasing or solvent cleaning operation unless conditions in R307-335-4(1) through (7) are met.
(1) A cover shall be installed which shall remain closed except during actual loading, unloading or handling of parts in cleaner. The cover shall be designed so that it can be easily operated with one hand if: (a) The volatility of the solvent is greater than 2 kPa (15 mm Hg or 0.3 psi) measured at 38 degrees C (100 degrees F),(b) The solvent is agitated, or(c) The solvent is heated.(2) An internal draining rack for cleaned parts shall be installed on which parts shall be drained until all dripping ceases. If the volatility of the solvent is greater than 4.3 kPa (32 mm Hg at 38 degrees C (100 degrees F)), the drainage facility must be internal, so that parts are enclosed under the cover while draining. The drainage facility may be external for applications where an internal type cannot fit into the cleaning system.(3) Waste or used solvent shall be stored in covered containers.(4) Tanks, containers and all associated equipment shall be maintained in good operating condition, and leaks shall be repaired immediately or the degreaser shall be shutdown.(5) Written procedures for the operation and maintenance of the degreasing or solvent cleaning equipment shall be permanently posted in an accessible and conspicuous location near the equipment.(6) If the solvent volatility is greater than 4.3 kPa (33 mm Hg or 0.6 psi) measured at 38 degrees C (100 degrees F), or if solvent is heated above 50 degrees C (120 degrees F), then one of the following control devices shall be used: (a) Freeboard that gives a freeboard ratio greater than 0.7;(b) Water cover if the solvent is insoluble in and heavier than water); or(c) Other systems of equivalent control, such as a refrigerated chiller or carbon adsorption.(7) If used, the solvent spray shall be a solid fluid stream at a pressure that does not cause excessive splashing and may not be a fine, atomized or shower type spray.Utah Admin. Code R307-335-4
Amended by Utah State Bulletin Number 2017-22, effective 10/29/2017