30 Tex. Admin. Code § 311.77

Current through Reg. 49, No. 45; November 8, 2024
Section 311.77 - Technical Demonstration
(a) The Technical Demonstration must include, at a minimum:
(1) a time schedule for the proposed quarry from initiation to termination of operations, including reclamation;
(2) a detailed description of the type of quarrying to be conducted, including the processes/methods employed (e.g., pit mining where blasting is employed);
(3) a geological description of the quarry area, including a detailed description of the material deposit: type, geographical extent, depth, and volume; and a description of the general area geology;
(4) identification and a detailed description of any other operations on site, including raw-material processing and/or secondary products (e.g., cement) processing;
(5) identification and a detailed description of type, character, and volume of wastewater and storm water generated on site;
(6) a topographic map, at a scale appropriate to represent the quarry operation and all of the following within the boundaries of the quarry:
(A) waterbodies;
(B) existing and proposed roads including quarry access roads;
(C) existing and proposed railroads;
(D) the 100-year floodplain boundaries, if applicable;
(E) structures (e.g., office buildings);
(F) the location of all known wells including, but not limited to, water wells, oil wells, and unplugged and abandoned wells;
(G) active, post, and reclaimed quarrying areas;
(H) buffer areas;
(I) raw material, intermediate material, final product, waste product, byproduct, and/or ancillary material storage and processing areas;
(J) chemical and fuel storage areas;
(K) vehicle/equipment maintenance, cleaning, and fueling areas;
(L) vehicle/equipment loading and unloading areas;
(M) baghouses and other air treatment units exposed to precipitation; and
(N) waste disposal areas;
(7) a Surface Water Drainage and Water Accumulation Plan. The Surface Water Drainage and Water Accumulation Plan must be designed to prevent damage to fish, wildlife, and fish/wildlife habitat from erosion, siltation, and runoff from quarry operations. The Surface Water Drainage and Water Accumulation Plan must, at a minimum:
(A) describe the use and monitoring of structural controls and best management practices as identified in paragraph (8) of this subsection designed to control erosion, siltation, and runoff; and
(B) provide a topographic map, at a scale appropriate to represent the quarry operation and all of the following within the boundaries of the quarry:
(i) the location of each process wastewater and/or storm water outfall;
(ii) an outline of the drainage area that contributes storm water to each outfall;
(iii) treatment, detention, and water storage tanks and ponds;
(iv) structural controls for managing storm water and/or process wastewater; and
(v) physical features of the site that would influence storm water runoff or contribute a dry weather flow; and
(8) a Best Available Technology Evaluation. The Best Available Technology Evaluation assists staff in reviewing and determining the best available technology designed to control erosion, siltation, and runoff from the quarry to minimize disturbance and adverse effects to fish, wildlife, and related environmental resources. Where practical, the Best Available Technology Evaluation must assist staff in reviewing and determining best available technology designed to enhance fish, wildlife, and related environmental resources.
(A) The Best Available Technology Evaluation must assess the use of structural controls and best management practices.
(B) The Best Available Technology Evaluation must evaluate performance criteria outlined in § 311.79 and § 311.80 of this title (relating to Performance Criteria and Additional Performance Criteria for Quarries Located Between 200 Feet and 1,500 Feet of a Water Body).
(C) Structural control design and construction must be certified by a licensed Texas professional engineer. Design and construction plans/specifications must be maintained on site and made available at the request of the executive director; and
(9) a procedure and schedule for reviewing the Technical Demonstration for consistency with quarry operations and site conditions and effectiveness in controlling erosion, siltation, and runoff.
(b) Certification of the Technical Demonstration must be provided, within the appropriate area or discipline, by a licensed Texas professional engineer or a licensed Texas professional geoscientist. Components of the Technical Demonstration may be independently certified, as appropriate.

30 Tex. Admin. Code § 311.77

The provisions of this §311.77 adopted to be effective August 3, 2006, 31 TexReg 6033; Amended by Texas Register, Volume 49, Number 28, July 12, 2024, TexReg 5146, eff. 7/18/2024