Current through Reg. 49, No. 45; November 8, 2024
Section 222.113 - Engineering ReportThe applicant shall submit an engineering report that includes the plans and specifications that:
(1) has been prepared by a licensed professional engineer;(2) addresses the proposed design, hydraulic and organic loadings, and the basis for the design for the subsurface area drip dispersal system and the treatment system;(3) a scale drawing of all land that is to be part of the subsurface area drip dispersal system showing the location of all existing and proposed facilities to include the following: (C) treatment facilities;(D) effluent storage; and(E) the buffer zones that demonstrate compliance with § 222.81 of this title (relating to Buffer Zone Requirements);(4) includes the site topography;(5) includes storm water run-on prevention and storm water runoff accommodation; and(6) includes any variance requests with supporting documentation.30 Tex. Admin. Code § 222.113
The provisions of this §222.113 adopted to be effective July 5, 2006, 31 TexReg 5308