30 Tex. Admin. Code § 217.326

Current through Reg. 49, No. 44; November 1, 2024
Section 217.326 - Electrical and Fire Code Compliance
(a) The electrical elements of a wastewater treatment facility and collection system must conform to local electrical codes. If the wastewater treatment facility or collection system is located in an area that does not have a local electrical code, the electrical elements must comply with the most recent edition of the National Fire Protection Association 70 National Electrical Code® at the time of installation.
(b) The wastewater treatment facility and collection system must conform to local fire codes. If the wastewater treatment facility is located in an area that does not have a local fire code, the wastewater treatment facility and collection system must comply with the most recent edition of National Fire Protection Association 1 Fire Code® at the time of installation.
(c) Electrical elements must be protected from environmental hazards with a housing. Environmental hazards include moisture, extreme temperatures, and pests.

30 Tex. Admin. Code § 217.326

The provisions of this §217.326 adopted to be effective August 28, 2008, 33 TexReg 6843; Amended by Texas Register, Volume 40, Number 47, November 20, 2015, TexReg 8340, eff. 12/4/2015