30 Tex. Admin. Code § 115.446

Current through Reg. 49, No. 43; October 25, 2024
Section 115.446 - Monitoring and Recordkeeping Requirements
(a) In the El Paso area as defined in § 115.10 of this title (relating to Definitions), the following monitoring and recordkeeping requirements apply.
(1) The owner or operator of a heatset offset lithographic printing press shall install, calibrate, maintain, and operate a temperature monitoring device, according to the manufacturer's instructions, at the outlet of the control device. The temperature monitoring device must be equipped with a continuous recorder and must have an accuracy of ±0.5 degrees Fahrenheit, or alternatively ±1.0% of the temperature being monitored.
(2) The owner or operator of any offset lithographic printing press shall install and maintain monitors to continuously measure and record operational parameters of any emission control device installed to meet applicable control requirements on a regular basis. Such records must be sufficient to demonstrate proper functioning of those devices to design specifications, including:
(A) the exhaust gas temperature of direct-flame incinerators or the gas temperature immediately upstream and downstream of any catalyst bed;
(B) the total amount of volatile organic compounds (VOC) recovered by a carbon adsorption or other solvent recovery system during a calendar month; and
(C) the exhaust gas VOC concentration of any carbon adsorption system, as defined in § 115.10 of this title, to determine if breakthrough has occurred.
(3) The dryer pressure must be maintained lower than the press room air pressure such that air flows into the dryer at all times when the offset lithographic printing press is operating. A 100% emissions capture efficiency for the dryer must be demonstrated using an air flow direction measuring device.
(4) The owner or operator of any offset lithographic printing press shall monitor fountain solution alcohol concentration with a refractometer or a hydrometer that is corrected for temperature at least once per eight-hour shift or once per batch, whichever is longer. The refractometer or hydrometer must have a visual, analog, or digital readout with an accuracy of 0.5% VOC. A standard solution must be used to calibrate the refractometer for the type of alcohol used in the fountain. The VOC content of the fountain solution may be monitored with a conductivity meter if it is determined that a refractometer or hydrometer cannot be used for the type of VOC in the fountain solution. The conductivity meter reading for the fountain solution must be referenced to the conductivity of the incoming water.
(5) The owner or operator of any offset lithographic printing press using refrigeration equipment on the fountain solution in order to comply with §115.442(a)(1)(A), (C), or (D) of this title (relating to Control Requirements) shall monitor the temperature of the fountain solution reservoir at least once per hour. Alternatively, the owner or operator of any offset lithographic printing press using refrigeration equipment on the fountain solution shall install, maintain, and continuously operate a temperature monitor of the fountain solution reservoir. The temperature monitor must be attached to a continuous recording device such as a strip chart, recorder, or computer.
(6) For any offset lithographic printing press with automatic cleaning equipment, flow meters are required to monitor water and cleaning solution flow rates. The flow meters must be calibrated so that the VOC content of the mixed solution complies with the requirements of § 115.442(a)(1) of this title.
(7) The owner or operator of any offset lithographic printing press shall maintain the results of any testing conducted at an affected facility in accordance with the provisions specified in § 115.445 of this title (relating to Approved Test Methods).
(8) The owner or operator of any offset lithographic printing press shall maintain all records at the affected facility for at least two years and make such records available upon request to authorized representatives of the executive director, the United States Environmental Protection Agency, or any local air pollution agency with jurisdiction.
(b) In the Dallas-Fort Worth and Houston-Galveston-Brazoria areas, the following monitoring and recordkeeping requirements apply in accordance with the appropriate compliance date specified in § 115.449 of this title (relating to Compliance Schedules).
(1) The owner or operator of an offset lithographic printing press claiming an exemption in § 115.441 of this title (relating to Exemptions) shall maintain records sufficient to demonstrate continuous compliance with the applicable exemption criteria. For example, maintaining records of ink, cleaning solvent, and fountain solution usage may be sufficient to demonstrate compliance with the exemption provided in § 115.441(a) of this title for sources located on a property with combined VOC emissions less than 3.0 tons per year when uncontrolled.
(2) The owner or operator of an offset lithographic printing press shall use one of the following options to demonstrate compliance with the cleaning solution content limits in § 115.442(b)(1) or (c)(1) of this title.
(A) Flow meters must be used to monitor the water and cleaning solution flow rates on a press with automatic cleaning equipment. The flow meters must be installed, maintained, and operated according to the manufacturer's instructions. The flow meters must be calibrated so that the VOC concentration of the cleaning solution complies with the requirements of § 115.442(b)(1) or (c)(1) of this title. Records must be sufficient to demonstrate continuous compliance with the cleaning solution content limits in § 115.442(b)(1) or (c)(1) of this title.
(B) The VOC concentration of each batch of cleaning solution must be determined using analytical data derived from the material safety data sheet (MSDS) or equivalent information from the supplier that was derived using the approved test methods in § 115.445 of this title. The concentration of all VOC used to prepare the batch and, if diluted prior to use, the proportions that each of these materials is used must be recorded for each batch of cleaning solution. Records must be sufficient to demonstrate continuous compliance with the cleaning solution content limits in § 115.442(b)(1) or (c)(1) of this title.
(3) The owner or operator of an offset lithographic printing press shall use one of the following options to demonstrate compliance with the fountain solution content limits in §115.442(b)(2) - (4) or (c)(2) - (4) of this title.
(A) The VOC concentration of each batch of fountain solution must be monitored using a refractometer or a hydrometer that is corrected for temperature. The refractometer or hydrometer must have a visual, analog, or digital readout with an accuracy of 0.5% VOC. A standard solution must be used to calibrate the refractometer for the type of alcohol used in the fountain solution. The VOC content of the fountain solution may be monitored with a conductivity meter if it is determined that a refractometer or hydrometer cannot be used for the type of VOC in the fountain solution. The conductivity meter reading for the fountain solution must be referenced to the conductivity of the incoming water. Records must be sufficient to demonstrate continuous compliance with the fountain solution content limits in §115.442(b)(2) - (4) or (c)(2) - (4) of this title.
(B) The VOC concentration of each batch fountain solution must be determined using analytical data from the MSDS or equivalent information from the supplier that was derived using the approved test methods in § 115.445 of this title. The concentration of all alcohols or alcohol substitutes used to prepare the batch and, if diluted prior to use, the proportions that each of these materials is used must be recorded for each batch of fountain solution. Records must be sufficient to demonstrate continuous compliance with the fountain solution content limits in §115.442(b)(2) - (4) or (c)(2) - (4) of this title.
(4) The owner or operator of an offset lithographic printing press using refrigeration equipment on the fountain solution reservoir shall monitor and record the fountain solution temperature at least once per hour. Temperature monitoring devices must be installed, maintained, and operated according to the manufacturer's specifications. Records must be sufficient to demonstrate continuous compliance with the fountain solution content limits in §115.442(b)(2) and (4) or (c)(2) and (4) of this title.
(5) The owner or operator of a heatset web offset lithographic printing press shall comply with the following monitoring and recordkeeping requirements to demonstrate continuous compliance with the control requirements in § 115.442(b)(5) of this title.
(A) Operational parameters of any emission control device installed to comply with the requirements in § 115.442(b)(5) of this title must be continuously measured and recorded. Monitors must be installed, calibrated, maintained, and operated according to the manufacturer's instructions. Temperature monitors must be equipped with a continuous recorder and have an accuracy of ±0.5 degrees Fahrenheit or ±1.0% of the temperature being monitored, whichever is less stringent. Measuring and recording the operational parameters of the control device at least once every 15 minutes is sufficient to demonstrate compliance with this subparagraph. Records must be sufficient to demonstrate proper functioning of the device to design specifications and must include:
(i) the exhaust gas temperature of direct-flame incinerators and/or the gas temperature immediately upstream and downstream of any catalyst bed;
(ii) the total amount of VOC recovered by a carbon adsorption system or other solvent recovery system per calendar month; and
(iii) the exhaust gas VOC concentration of any carbon adsorption system to determine if breakthrough has occurred.
(B) An air flow direction measuring device must be used to demonstrate the dryer meets the 100% capture efficiency required in § 115.442(b)(5) of this title.
(6) The owner or operator of an offset lithographic printing press shall maintain the results of any tests conducted using the approved test methods in § 115.445 of this title.
(7) The owner or operator of an offset lithographic printing press shall maintain all records for at least two years and make such records available upon request to authorized representatives of the executive director, the United States Environmental Protection Agency, or any local air pollution agency with jurisdiction.

30 Tex. Admin. Code § 115.446

The provisions of this §115.446 adopted to be effective December 3, 1993, 18 TexReg 8538; amended to be effective May 27, 1994, 19 TexReg 3703; amended to be effective March 7, 1996, 21 TexReg 1548; amended to be effective May 22, 1997, 22 TexReg 4213; amended to be effective March 21, 1999, 24 TexReg 1777; amended to be effective May 16, 2002, 27 TexReg 4113; amended to be effective April 1, 2010, 35 TexReg 2579; Amended by Texas Register, Volume 40, Number 25, June 19, 2015, TexReg 3958, eff. 6/25/2015