30 Tex. Admin. Code § 115.117

Current through Reg. 49, No. 44; November 1, 2024
Section 115.117 - Approved Test Methods

For the Beaumont-Port Arthur, Dallas-Fort Worth, El Paso, and Houston-Galveston-Brazoria areas, as defined in § 115.10 of this title (relating to Definitions) and Gregg, Nueces, and Victoria Counties, compliance with the requirements in this division must be determined by applying the following test methods, as appropriate:

(1) Methods 1 - 4 (40 Code of Federal Regulations (CFR) Part 60, Appendix A) for determining flow rates, as necessary;
(2) Method 18 (40 CFR Part 60, Appendix A) for determining gaseous organic compound emissions by gas chromatography;
(3) Method 21 (40 CFR Part 60, Appendix A-7) for determining volatile organic compounds concentrations for the purposes of determining the presence of leaks and determining breakthrough on a carbon adsorption system or carbon adsorber. If the owner or operator chooses to conduct a test to verify a vapor-tight requirement, Method 21 is acceptable;
(4) Method 22 (40 CFR Part 60, Appendix A) for determination of visible emissions from flares;
(5) Method 25 (40 CFR Part 60, Appendix A) for determining total gaseous nonmethane organic emissions as carbon;
(6) Methods 25A or 25B (40 CFR Part 60, Appendix A) for determining total gaseous organic concentrations using flame ionization or nondispersive infrared analysis;
(7) test method described in 40 CFR §60.113a(a)(1)(ii) (effective April 8, 1987) for measurement of storage tank seal gap;
(8) true vapor pressure must be determined using standard reference texts or ASTM International Test Method D323, D2879, D4953, D5190, D5191, or D6377 for the measurement of Reid vapor pressure, adjusted for actual storage temperature in accordance with American Petroleum Institute Publication 2517. For the purposes of temperature correction, the owner or operator shall use the actual storage temperature. Actual storage temperature of an unheated storage tank may be determined using the maximum local monthly average ambient temperature as reported by the National Weather Service. Actual storage temperature of a heated storage tank must be determined using either the measured temperature or the temperature set point of the storage tank;
(9) mass flow meter, positive displacement meter, or similar device for measuring the volumetric flow rate of flash, working, breathing, and standing emissions from crude oil and condensate over a 24-hour period representative of normal operation. For crude oil and natural gas production sites, volumetric flow rate measurements must be made while the producing wells are operational;
(10) test methods referenced in paragraphs (2), (5), and (6) of this section or Gas Processors Association Method 2286, Tentative Method of Extended Analysis for Natural Gas and Similar Mixtures by Temperature Programmed Gas Chromatography, to measure the concentration of volatile organic compounds in flashed gases from crude oil and condensate storage;
(11) test methods other than those specified in this section may be used if validated by 40 CFR Part 63, Appendix A, Test Method 301 and approved by the executive director; or
(12) minor modifications to these test methods approved by the executive director.

30 Tex. Admin. Code § 115.117