S.D. Admin. R. 74:53:01:32

Current through Register Vol. 51, page 67, December 16, 2024
Section 74:53:01:32 - Alternative method of determining required absorption trench system area

In lieu of calculating the absorption trench system area according to §§ 74:53:01:30 and 74:53:01:31, the following criteria in Table 5 may be used for the design of individual or small on-site wastewater systems if the absorption trench system is of an area sufficient for at least three bedrooms. The absorption area shall be determined according to the following table:

TABLE 5

Percolation Rate

Minimum Absorption Trench Area

(Minutes for water to drop one inch)

(Square feet of trench bottom per bedroom)

1 but less than 5 minutes per inch

Not permitted--see § 74:53:01:33

5 but less than 10 minutes per inch

125 square feet

10 but less than 15 minutes per inch

165 square feet

15 but less than 30 minutes per inch

200 square feet

30 but less than 45 minutes per inch

250 square feet

45 but less than 55 minutes per inch

300 square feet

55 but no more than 60 minutes per inch

350 square feet

Over 60 minutes per inch

Not permitted--see § 74:53:01:33

The minimum absorption trench area, as shown in the above table, may be reduced in accordance with § 74:53:01:31 when the depth of fill material below the distribution pipe is 12 inches or greater.

S.D. Admin. R. 74:53:01:32

12 SDR 2, effective 7/18/1985; 13 SDR 129, 13 SDR 141, effective 7/1/1987; transferred from

General Authority: SDCL 34A-2-93.

Law Implemented: SDCL 34A-2-20.