S.D. Admin. R. 74:51:01:44

Current through Register Vol. 51, page 67, December 16, 2024
Section 74:51:01:44 - Criteria for domestic water supply waters

The criteria of parameters for domestic water supply waters and their allowable variations that are not included under § 74:51:01:55 and Appendix B, unless set under § 74:51:01:24, are as found in the following table:

Parameter

Criteria

Unit of Measure

Special Conditions

Total dissolved solids

<= 1,000

mg/L

30-day average

<= 1,750

mg/L

daily maximum

Nitrates as N

<= 10

mg/L

daily maximum

pH

>= 6.5 - <= 9.0

units

Total Coliform

<= 5,000

/100 mL

geometric mean of a minimum of 5 samples during separate 24-hour periods for a 30-day period and may not exceed this value in more than 20 percent of the samples examined in the same 30-day period

<= 20,000

/100 mL

in any one sample

Barium

<= 1.0

mg/L

daily maximum

Chloride

<= 250

mg/L

30-day average

<= 438

mg/L

daily maximum

Fluoride

<= 4.0

mg/L

daily maximum

Sulfate

<= 500

mg/L

30-day average

<= 875

mg/L

daily maximum

Total Petroleum Hydrocarbons

<= 1.0

mg/L

daily maximum

S.D. Admin. R. 74:51:01:44

SL 1975, ch 16; 47 SDR 110, effective 4/27/2021

General Authority: SDCL 34A-2-11, 34A-2-93.

Law Implemented: SDCL 34A-2-10, 34A-2-11.