Section 74:36:07:118 - Existing municipal solid waste landfill enclosed combustor monitoring

The owner or operator of an existing municipal solid waste landfill that seeks to comply with § 74:36:07:109 using an enclosed combustor shall install, calibrate, maintain, and operate according to the manufacturers specifications, the following equipment:

1. A temperature monitoring device equipped with a continuous recorder and having a minimum accuracy of ±1 percent of the temperature being measured expressed in degrees Celsius or ±0.5 degrees Celsius, whichever is greater. A temperature monitoring device is not required for boilers or process heaters with design heat input capacity equal to or greater than 44 megawatts; and
2. A device that records flow to the control device and bypass of the control device, if applicable, at least every 15 minutes. The owner or operator shall secure the bypass line valve in the closed position with a car-seal or a lock-and-key type configuration. A visual inspection of the seal or closure mechanism shall be performed at least once every month to ensure the valve is maintained in the closed position and the gas flow is not diverted through the bypass line.

S.D. Admin. R. 74:36:07:118

46 SDR 064, effective 11/25/2019

General Authority: SDCL 34A-1-6.

Law Implemented: SDCL 34A-1-18.