Section 20:74:06:09 - Interior components for inspection - Exclusions

A home inspector shall inspect interior components as follows:

(1) The inspector shall observe and report on the general appearance and condition of the following:
(a) General interior:
(i) Walls, ceilings, and floors;
(ii)Doors, to include the operation of doors, missing or malfunctioning hardware, and proper fit;
(iii) Windows, to include the operation of a representative number of windows, presence of double or single pane glass, evidence of leakage, visible entrapped moisture between seals on double pane windows, and broken window panes;
(iv) Skylights, to include the condition of skylight glass, presence of condensation or leakage stains, and the operation of the skylight, if possible;
(v) Stairways, to include the presence or absence of handrails;
(vi) Balconies, to include the presence and condition of guardrails;
(vii) Interior electrical/mechanical/heating, ventilation, and air conditioning systems;
(viii) A representative number of electrical outlets for proper connection and grounding;
(ix) All light switches;
(x) All ceiling fans;
(xi) Presence or absence of a heating source in each living area; and
(xii) Functional operation of the heating source;
(b) Bathrooms:
(i) Functional flow for each water source, including hot water at each hot water source;
(ii)Functional drainage at each drain, the presence of an operating stop at each drain, and signs of leakage;
(iii) Presence or absence of a ventilation fan, the operation of the fan, and discharge to outside, if possible; and
(iv) Operating windows;
(c) Laundry:
(i) Presence of a power source for a clothes dryer - gas or electric - and presence of a vent line; and
(ii)Presence of hot and cold water connections, presence of a drain, and presence of 110 volt power;
(d) Kitchen:
(i) Permanently installed cabinets and countertops;
(ii)Stove/oven, to include the fuel type - electric, natural gas, or propane - and the operation of heating elements;
(iii) Ventilation fan and light - operation - exhaust to outside or recirculating;
(iv) Refrigerator - operation at time of inspection;
(v) Dishwasher - operation at time of inspection, verify functional flow and drainage;
(vi) Garbage disposal - verify functional operation;
(vii) Compactor - verify functional operation; and
(viii) Microwave (permanent) - verify presence;
(e) Safety devices:
(i) Ground fault circuit interrupters -- breaker or outlet type, trip from test button, trip from external tester; and
(ii)Smoke detectors - hard wired or battery, test from test button on unit;
(2) The inspector is not required to:
(a) Test minor functions of appliances;
(b) Test minor appliances;
(c) Operate every window;
(d) Test every electrical outlet;
(e) Observe paint, wallpaper, or other wall finish treatments;
(f) Observe carpeting;
(g) Observe draperies, blinds, or other window treatments;
(h) Report on water filtering devices;
(i) Evaluate shower pans for leakage;
(j) Evaluate water softening or other conditioning systems;
(k) Report on phone lines, cable lines, intercoms, alarms, or other low voltage signal systems;
(l) Operate any plumbing or gas shut-off valves;
(m) Report on condition of relay operated lights;
(n) Determine adequacy of plumbing systems (including hot water capacity, pressure, and flow);
(o) Test electrical timers;
(p) Test Jacuzzi tubs or hot tubs; or
(q) Test carbon monoxide detectors.