S.C. Code Regs. § § 8-1206

Current through Register Vol. 48, No. 11, November 22, 2024
Section 8-1206 - IRC R302.5.1 Opening protection

Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and residence shall be equipped with solid wood doors not less than 1 3/8 inches (35 mm) in thickness, solid or honeycomb core steel doors not less than 1 3/8 inches (35 mm) thick, or 20-minute fire-rated doors.

S.C. Code Regs. § 8-1206