Section 103-663.3 - Subscriber Loop-Transmission Objectives

The following standards are objectives to be used by the ORS staff during testing at the subscriber's station protector. Acceptable measurements are:

DC Line Current: greater than 20 mA

Circuit Loss: less than 8.5 db

Circuit Noise: less than 20 dBrnC

Power Influence: less than 90 dBrnC

Balance greater than 60 dB

(Where Balance (dB) = Power Influence - Circuit Noise)