Product Type | Minimum AFUE | Maximum electricity ratio |
Natural gas and propane- fired furnaces | 90% | 2.0% |
Oil-fired furnaces > 94,000 Btu/hour in capacity | 83% | 2.0% |
Oil-fired furnaces <94,000 Btu/hour in capacity | 83% | 2.3% |
Natural gas and oil, and propane-fired hot water residential boilers | 84% | Not applicable |
Natural gas, oil, and propane-fired steam residential boilers | 82% | Not applicable |
Nameplate Output | Minimum Efficiency in Active Mode |
0 to <1 Watt | 0.49* Nameplate Output |
>1 and <= 49 Watts | 0.09 * Ln(Nameplate Output) + 0.49 |
> 49 Watts | 0.84 |
Maximum Energy Consumption in No-Load Mode | |
0 to <10 Watts | 0.5 Watts |
=>10 to <= 250 Watts | 0.75 Watts |
Where Ln (Nameplate Output) = Natural Logarithm of the nameplate output expressed in Watts |
MOTOR Type | Required Components |
All | Interior lights: light sources with an efficacy of forty-five (45) lumens per watt or more, including ballast losses (if any). This efficacy standard does not apply to LED light sources until January 1, 2010. |
All | Automatic door closers that firmly close all reach-in doors. |
All | Automatic door closers that firmly close all walk-in doors no wider than 3.9 feet and no higher than 6.9 feet that have been closed to within one inch of full closure. |
All | Wall, ceiling, and door insulation at least R-28 for refrigerators and at least R-34 for freezers |
All | Floor insulation at least R-28 for freezers (no requirements for refrigerators) |
Condenser fan motors of under one horsepower | Permanently split capacitor-type motors Polyphase motors of one-half (1/2) horsepower or more |
Single-phase evaporator fan motors of under one horsepower and less than 460 volts | Electronically commutated motors |
810 R.I. Code R. 810-RICR-50-00-1.5