Add the following sections to section 601 General:
After construction or repair, the individual water supply system shall be purged of deleterious matter and disinfected in accordance with IPC Section 610.
Delete IPC 603.2 and substitute the following:
Exceptions:
Delete IPC Table 608.17.1 and substitute the following:
TABLE 608.17.1
DISTANCE FROM SOURCES OF CONTAMINATION TO PRIVATE WATER SUPPLIES AND PUMP SUCTION LINES
Source of Contamination | Distance (feet) a, b |
Sewer | 50 |
Septic Tank | 50 |
Pasture | 100 |
Sewer (leaded or mechanical joints or approved plastic) | 10 |
Subsurface pits | 100c |
Seepage pits | 100 |
Cesspools | 100 |
Barnyard | 100 |
Farm silo | 25 |
Pump house floor drain of cast iron draining to ground surface | 2 |
Note a. 1 foot = 304.8mm
Note b. These distances constitute minimum separation and shall be increased in areas of crevice rock or limestone, or where the direction of the ground water is from sources of contamination toward the well. These distances shall be increased as required by the Rhode Island Department of Environmental Management, Division of Land Resources (SDS Regulations or local zoning ordinances).
Note c. When approved by the authority having jurisdiction and under special soil conditions, this distance may be reduced; however, a minimum separation of not less than fifty feet (50') shall be maintained.
510 R.I. Code R. 510-RICR-00-00-3.5
Amended effective 2/1/2022