Length, Feet | Minimum number of hand portable fire extinguishersrequired* (Type B) | |
No fixed fire extinguishing system in machinery space | Fixed Fire extinguishing system in machinery space | |
Under 16 | 1 | 0 |
16, but less than 26 | 1 | 0 |
26, but less than 40 | 2 | 1 |
40 and over | 3 | 2 |
*Note: Extinguishers required by the above table can either be one B-I or 5-B portable fire extinguisher. One B-II or 20-B portable fire extinguisher may be substituted for two B-I or 5-B portable fire extinguishers.
______________________________________
Pa. Code tit. 58, pt. II, subpt. C, ch. 97, app B
The provisions of this Appendix B amended under section 506 of The Administrative Code of 1929 (71 P.S. § 186) and section 204 of the Commonwealth Documents Law (45 P.S. § 1204).
This appendix cited in 58 Pa. Code § 97.2 (relating to fire extinguisher).