Current through Register Vol. 63, No. 10, October 1, 2024
Section 340-234-0540 - Board Products Industries (Veneer, Plywood, Particleboard, Hardboard): Testing and MonitoringAll source tests must be done using the DEQ Source Sampling Manual. [NOTE: The DEQ Source Sampling Manual is published with OAR 340-200-0035.]
(1) Veneer dryers, wood particle dryers, fiber dryers and press/cooling vents must be tested using DEQ Method 7.(2) Air conveying systems must be tested using DEQ Method 8.(3) Fuel burning equipment must be tested using DEQ Method 5. When combusting wood fuel by itself or in combination with any other fuel, the emission results are corrected to 12% CO2. When combusting fuels other than wood, the emission results are corrected to 50% excess air. [NOTE: This rule is included in the State of Oregon Clean Air Act Implementation Plan that EQC adopted under OAR 340-200-0040.]
Or. Admin. Code § 340-234-0540
DEQ 7-2015, f. & cert. ef. 4/16/2015; DEQ 13-2019, amend filed 05/16/2019, effective 5/16/2019Statutory/Other Authority: ORS 468.020, 468A.025 & 468A.070
Statutes/Other Implemented:468A.025 & 468A.070