Or. Admin. Code § 340-232-0220

Current through Register Vol. 63, No. 10, October 1, 2024
Section 340-232-0220 - Flat Wood Coating
(1) This rule applies to all flat wood manufacturing and surface finishing facilities that manufacture the following products:
(a) Printed interior panels made of hardwood plywood and thin particleboard;
(b) Natural finish hardwood plywood panels; or
(c) Hardboard paneling with Class II finishes.
(2) This rule does not apply to the manufacture of exterior siding, tileboard, particleboard used as a furniture component, or paper or plastic laminates on wood or wood-derived substrates.
(3) No owner or operator of a flat wood manufacturing facility subject to this rule may emit VOCs from a coating application system in excess of:
(a) 2.9 kilograms per 100 square meters of coated finished product (6.0 pounds/1,000 square feet) from printed interior panels, regardless of the number of coats applied;
(b) 5.8 kilograms per 100 square meters of coated finished product (12.0 pounds/1,000 square feet) from natural finish hardwood plywood panels, regardless of the number of coats applied; and
(c) 4.8 kilograms per 100 square meters of coated finished product (10.0 pounds/1,000 square feet) from Class II finishes on hardboard panels, regardless of the number of coats applied.
(4) The emission limits in section (3) must be achieved by:
(a) The application of low solvent content coating technology; or
(b) An incineration system which oxidizes at least 90.0 percent of the non methane VOCs entering the incinerator (VOC measured as total combustible carbon) to carbon dioxide and water; or
(c) An equivalent means of VOC removal. The equivalent means must be approved in writing by DEQ. The time period used to determine equivalency may not exceed 24 hours.
(5) A capture system must be used in conjunction with the control devices in subsections (4)(b) and (c). The design and operation of a capture system must be consistent with good engineering practice and must provide for an overall emission reduction sufficient to meet the emission limitations in section (3).
(6) Compliance Demonstration:
(a) The owner or operator of a VOC source required to comply with this rule must demonstrate compliance by the methods of subsection (c), or an alternative method approved by DEQ;
(b) A person proposing to conduct a VOC emissions test must notify DEQ of the intent to test not less than 30 days before the proposed initiation of the tests so DEQ may observe the test;
(c) Test procedures in 40 CFR part 60, EPA Method 18, 24, or 25 must be used to determine compliance with section (3);
(d) DEQ may accept, instead of the coating analysis required by paragraph (c)(A), a certification by the coating manufacturer of the composition of the coating, if supported by actual batch formulation records. In the event of any inconsistency between a Method 18, 24, or 25 test and a facility's formulation data, the Method 18, 24, or 25 test will govern;
(e) If an add-on control device is used, continuous monitors of the following parameters must be installed, periodically calibrated, and operated at all times that the associated control device is operating:
(A) Exhaust gas temperature of all incinerators;
(B) Temperature rise across a catalytic incinerator bed; and
(C) Breakthrough of VOC on a carbon absorption unit.

[NOTE: This rule is included in the State of Oregon Clean Air Act Implementation Plan that EQC adopted under OAR 340-200-0040.]

[NOTE: View a PDF of referenced EPA Methods by clicking on "Tables' link below OAR 340-232-8010.]

Or. Admin. Code § 340-232-0220

DEQ 23-1980, f. & ef. 9-26-80; DEQ 8-1991, f. & cert. ef. 5-16-91; DEQ 4-1993, f. & cert. ef. 3-10-93; DEQ 14-1999, f. & cert. ef. 10-14-99, Renumbered from 340-022-0200; DEQ 7-2015, f. & cert. ef. 4/16/2015; DEQ 144-2018, minor correction filed 04/11/2018, effective 04/11/2018; DEQ 13-2019, amend filed 05/16/2019, effective 5/16/2019

Statutory/Other Authority: ORS 468.020, 468A.025 & 468A.070

Statutes/Other Implemented: ORS 468A.025 & 468A.070