Or. Admin. Code § 333-121-0130

Current through Register Vol. 63, No. 11, November 1, 2024
Section 333-121-0130 - Fire Protection
(1) The radiation room at a panoramic irradiator must have heat and smoke detectors. The detectors must activate an audible alarm. The alarm must be capable of alerting a person who is prepared to summon assistance promptly. The sources must automatically become fully shielded if a fire is detected.
(2) The radiation room at a panoramic irradiator must be equipped with a fire extinguishing system capable of extinguishing a fire without the entry of personnel into the room. The system for the radiation room must have a shut-off valve to control flooding into unrestricted areas.

Or. Admin. Code § 333-121-0130

PH 5-2005, f. & cert. ef. 4-11-05

Stat. Auth.: ORS 453.675

Stats. Implemented: ORS 453.675