Section 380:50-15-13 - Emergency exits

The contractor shall establish visible and illuminated emergency and fire exits from the work area. Emergency procedures shall have priority. Emergency lighting shall have:

(1) Battery back-up.
(2) Sufficient power to illuminate obstructions between all areas of the containment and the exits.