[Comment: When a reference is made within this rule to a federal statutory provision, an industry consensus standard, or any other technical publication, the specific date and title of the publication as well as the name and address of the promulgating agency are listed in rule 4101:8-44-01 of the Administrative Code. The application of the referenced standards shall be limited and as prescribed in section 102.5 of rule 4101:8-1-01 of the Administrative Code.]
GENERAL
INTERIOR COVERING
TABLE 702.1(1)
THICKNESS OF PLASTER
PLASTER BASE | FINISHED THICKNESS OF PLASTER FROM FACE OF LATH, MASONRY, CONCRETE (inches) | |
Gypsum Plaster | Cement Plaster | |
Expanded metal lath | 5/8, minimuma | 5/8, minimuma |
Wire lath | 5/8, minimuma | 3/4, minimum (interior)b 7/8, minimum (exterior)b |
Gypsum lathg | 1/2, minimum | 3/4, minimum (interior)b |
Masonry wallsc | 1/2, minimum | 1/2, minimum |
Monolithic concrete wallsc, d | 5/8, maximum | 7/8, maximum |
Monolithic concrete ceilingsc, d | 3/8, maximume | 1/2, maximum |
Gypsum veneer basef, g | 1/16, minimum | 3/4, minimum (interior)b |
Gypsum sheathingg | - | 3/4, minimum (interior)b 7/8, minimum (exterior)b |
For SI: 1 inch = 25.4 mm.
TABLE 702.1(2)
GYPSUM PLASTER PROPORTIONSa
NUMBER | COAT | PLASTER BASE OR LATH | MAXIMUM VOLUME AGGREGATE PER 100 POUNDS NEAT PLASTERb (cubic feet) | |
Damp Loose Sanda | Perlite or Vermiculitec | |||
Two-coat | Base coat | Gypsum lath | 2.5 | 2 |
work | Base coat | Masonry | 3 | 3 |
First coat | Lath | 2d | 2 | |
Three-coat | Second coat | Lath | 3d | 2e |
work | First and second coats | Masonry | 3 | 3 |
For SI: 1 inch = 25.4 mm, 1 cubic foot = 0.0283 m3, 1 pound = 0.454 kg.
TABLE 702.1(3)
CEMENT PLASTER PROPORTIONS, PARTS BY VOLUME
CEMENTITIOUS MATERIALS | ||||||
COAT | CEMENT PLASTER TYPE | Portland Cement Type I, II or III; Blended Hydraulic Cement Type IP, I (S < 70), IL, or IT (S < 70); or Hydraulic Cement Type GU, HE, MS, HS or MH | Plastic Cement | Masonry Cement Type M, S or N | Lime | VOLUME OF AGGREGATE PER SUM OF SEPARATE VOLUMES OF CEMENTITIOUS MATERIALSb |
First | Portland or blended | 1 | - | - | 3/4 - 11/2a | 21/2 - 4 |
Masonry | - | 1 | - | 21/2 - 4 | ||
Plastic | - | 1 | - | - | 21/2 - 4 | |
Second | Portland or blended | 1 | - | - | 3/4 - 11/2 | 3 - 5 |
Masonry | - | 1 | - | 3 - 5 | ||
Plastic | - | 1 | - | - | 3 - 5 | |
Finish | Portland or blended | 1 | - | - | 11/2 - 2 | 11/2 - 3 |
Masonry | - | - | 1 | - | 11/2 - 3 | |
Plastic | - | 1 | - | 11/2 - 3 |
For SI: 1 inch = 25.4 mm, 1 pound = 0.454 kg.
Exception:Applications installed in accordance with ASTM C926.
TABLE 702.3.5
MINIMUM THICKNESS AND APPLICATION OF GYPSUM BOARD AND GYPSUM PANEL PRODUCTS
THICKNESS OF GYPSUM BOARD OR GYPSUM PANEL PRODUCTS (inches) | APPLICATION | ORIENTATION OF GYPSUM BOARD OR GYPSUM PANEL PRODUCTS TO FRAMING | MAXIMUM SPACING OF FRAMING MEMBERS (inches o.c.) | MAXIMUM SPACING OF FASTENERS (inches) Nailsa | Screwsb | SIZE OF NAILS FOR APPLICATION TO WOOD FRAMINGc |
Application without adhesive | ||||||
3/8 | Ceilingd | Perpendicular | 16 | 7 | 12 | 13 gage, 11/4" long, 19/64 head; 0.098 " diameter, 11/4" long, annular-ringed; |
Wall | Either direction | 16 | 8 | 16 | or 4d cooler nail, 0.080 " diameter, 13/8" long, 732" head. | |
1/2 | Ceiling | Either direction | 16 | 7 | 12 | 13 gage, 13/8" long, 1 9/64" head; |
Ceilingd | Perpendicular | 24 | 7 | 12 | 0.098 " diameter, 11/4" long, annular-ringed; | |
Wall | Either direction | 24 | 8 | 12 | 5d cooler nail, 0.086 " diameter, 15/8 long, "15/64" head; or gypsum board nail, | |
Wall | Either direction | 16 | 8 | 16 | 0.086 " diameter, 15/8" long, 9/ 32" head. | |
5/8 | Ceiling | Either direction | 16 | 7 | 12 | 13 gage, 15/8" long, 1964/" head; 0.098 " diameter, 13/8" long, annular-ringed; |
Ceiling | Perpendicular | 24 | 7 | 12 | 6d cooler nail, 0.092" diameter, 17/8" long, 1/4" head; or gypsum board nail, 0.0915 diameter, 17/8" long, 19/64" head. | |
Type X at garage ceiling beneath habitable rooms | Perpendicular | 24 | 6 | 6 | 17/8" long 6d coated nails or equivalent drywall screws. Screws shall comply with Section 702.3.5.1 | |
Wall | Either direction | 24 | 8 | 12 | 13 gage, 15/8" long, 19/64" head; 0.098 diameter, 13/8" long, annular-ringed; 6d cooler nail, 0.092 " diameter, 17/8" long, | |
Wall | Either direction | 16 | 8 | 16 | 1/4" head; or gypsum board nail, 0.0915 " diameter, 17/8" long, 19/64" head. | |
Application with adhesive | ||||||
3/8 | Ceilingd | Perpendicular | 16 | 16 | 16 | Same as above for3/8" gypsum board and |
Wall | Either direction | 16 | 16 | 24 | gypsum panel products. | |
Ceiling | Either direction | 16 | 16 | 16 | Same as above for 1/2" and 5/8" gypsum board and gypsum panel products, respectively. | |
1/2 or 5/8 | Ceilingd | Perpendicular | 24 | 12 | 16 | |
Wall | Either direction | 24 | 16 | 24 | ||
3 | Ceiling | Perpendicular | 16 | 16 | 16 | Base ply nailed as above for1/2" gypsum installed with adhesive. |
8 | Wall | Either direction | 24 | 24 | 24 |
For SI: 1 inch = 25.4 mm.
TABLE 702.3.6
SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAMED GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
MATERIAL | THICKNESS OF MATERIAL (min.) (inch) | SPACING OF FRAMING MEMBERS (max.) (inch) | SHEAR VALUEa, b(plf of ceiling) | MINIMUM FASTENER SIZEc, d |
Gypsum board or gypsum panel product | 1/2 | 16 o.c. | 90 | 5d cooler or wallboard nail; 15/8-inch long; 0.086 -inch shank; 15/64-inch head |
Gypsum board or gypsum panel product | 1/2 | 24 o.c. | 70 | 5d cooler or wallboard nail; 15/8-inch long; 0.086 -inch shank; 15/64-inch head |
For SI: 1 inch = 25.4 mm, 1 pound per linear foot = 1.488 kg/m.
TABLE 702.4.2
BACKER BOARD MATERIALS
MATERIAL | STANDARD |
Glass mat gypsum backing panel | ASTM C1178 |
Fiber-reinforced gypsum panels | ASTM C1278 |
Nonasbestos fiber-cement backer board | ASTM C1288 or ISO 8336, Category C |
Nonasbestos fiber mat-reinforced cementitious backer units | ASTM C1325 |
Exceptions:
TABLE 702.7.1
CLASS III VAPOR RETARDERS
CLIMATE ZONE | CLASS III VAPOR RETARDERS PERMITTED FOR:a |
5 | Vented cladding over wood structural panels. Vented cladding over fiberboard. Vented cladding over gypsum. |
Continuous insulation with R-value> 5 over 2 × 4 wall. Continuous insulation with R-value> 7.5 over 2 × 6 wall. | |
6 | Vented cladding over fiberboard. Vented cladding over gypsum. Continuous insulation with R-value > 7.5 over 2 × 4 wall. Continuous insulation with R-value > 11.25 over 2 × 6 wall. |
For SI: 1 pound per cubic foot = 16 kg/m3.
The following shall be deemed to meet the class specified:
For the purposes of this section, vented cladding shall include the following minimum clear airspaces. Other openings with the equivalent vent area shall be permitted.
EXTERIOR COVERING
Exception:Log walls designed and constructed in accordance with the provisions of ICC 400.
Exceptions:
The exterior wall envelope design shall be considered to resist wind-driven rain where the results of testing indicate that water did not penetrate control joints in the exterior wall envelope, joints at the perimeter of openings penetration or intersections of terminations with dissimilar materials.
TABLE 703.3(1)
SIDING MINIMUM ATTACHMENT AND MINIMUM THICKNESS
SIDING MATERIAL | NOMINAL THICKNESS (inches) | JOINT TREATMENT | TYPE OF SUPPORTS FOR THE SIDING MATERIAL AND FASTENERS | ||||||
Wood or wood structural panel sheathing into stud | Fiberboard sheathing into stud | Gypsum sheathing into stud | Foam plastic sheathing into stud1 | Direct to studs | Number or spacing of fasteners | ||||
Anchored veneer: brick, concrete, masonry or stone (see Section 703.8) | 2 | Section 703.8 | Section 703.8 | ||||||
Adhered veneer: concrete, stone or masonry (see Section 703.12) | - | Section 703.12 | Section 703.12 | ||||||
Fiber cement siding | Panel siding (see Section 703.10.1) | 5/16 | Section 703.10.1 | 6d common (2"x 0.113 ") | 6d common (2"x 0.113 ") | 6d common (2"x 0.113 ") | 6d common (2"x 0.113 ") | 4d common (11/2" x 0.099 ") | 6" panel edges 12" inter. sup. |
Lap siding (see Section 703.10.2) | 5/16 | Section 703.10.2 | 6d common (2"x 0.113 ") | 6d common (2"x 0.113 ") | 6d common (2"x 0.113 ") | 6d common (2"x 0.113 ") | 6d common (2"x 0.113 ") or 11 gage roofing nail | Note f | |
Hardboard panel siding (see Section 703.5) | 7/16 | - | 0.120 " nail (shank) with 0.225 " head | 0.120 " nail (shank) with 0.225 " head | 0.120 " nail (shank) with 0.225 " head | 0.120 " nail (shank) with 0.225 " head | 0.120 " nail (shank) with 0.225 " head | 6" panel edges 12" inter. sup.d | |
Hardboard lap siding (see Section 703.5) | 7/16 | Note e | 0.099 " nail (shank) with 0.240 " head | 0.099 " nail (shank) with 0.240 " head | 0.099 " nail (shank) with 0.240 " head | 0.099 " nail (shank) with 0.240 " head | 0.099 " nail (shank) with 0.240 " head | Same as stud spacing 2 per bearing | |
Horizontal aluminuma | Without insulation | 0.019 b | Lap | Siding nail 11/2"x 0.120 " | Siding nail 2"x 0.120 " | Siding nail 2"× 0.120 " | Siding nail h 11/2" x 0.120 " | Not allowed | Same as stud spacing |
0.024 | Lap | Siding nail 11/2" x 0.120 " | Siding nail 2"x 0.120 " | Siding nail 2"× 0.120 " | Siding nail h 11/2" x 0.120 " | Not allowed | |||
With insulation | 0.019 | Lap | Siding nail 11/2" x 0.120 " | Siding nail 21/2" x 0.120 " | Siding nail 21/2" x 0.120 " | Siding nail h 11/2" x 0.120 " | Siding nail 11/2" x 0.120 " | ||
Insulated vinyl sidingj | 0.035 (vinyl siding layer only) | Lap | 0.120 nail (shank) with a 0.313 head or 16-gage Crownh, i | 0.120 nail (shank) with a 0.313 head or 16-gage Crownh | 0.120 nail (shank) with a 0.313 head or 16-gage Crown h | 0.120 nail (shank) with a 0.313 head Section 703.11.2 | Not allowed | 16 inches on center or specified by manufacturer instructions, test report or other sections of this code | |
Particleboard panels | 3/8 | - | 6d box nail (2" x 0.099 ") | 6d box nail (2" x 0.099 ") | 6d box nail (2" x 0.099 ") | 6d box nail (2" x 0.099 ") | Not allowed | 6" panel edges 12" inter. sup. | |
1/2 | - | 6d box nail (2" x 0.099 n) | 6d box nail (2" x 0.099 ") | 6d box nail (2" x 0.099 ") | 6d box nail (2"x 0.099 ") | 6d box nail (2"x 0.099 n) | |||
5/8 | - | 6d box nail (2"x 0.099 ") | 8d box nail (21/2x 0.113 ") | 8d box nail (21/2× 0.113 ) | 6d box nail (2" x 0.099 ") | 6d box nail (2" x 0.099 ") | |||
Polypropylene siding k | Not applicable | Lap | Section 703.14.1 | Section 703.14.1 | Section 703.14.1 | Section 703.14.1 | Not allowed | As specified by the manufacturer instructions, test report or other sections of this code | |
Steel c | 29 ga. | Lap | Siding nail (13/4" 0.113 ") Staple-13/4' | Siding nail (23/4" 0.113 ")Staple-21/2" | Siding nail (21/2 x 0.113) Staple. 21/4 | Siding nail (13/4 "x 0.113 ") Staple-13/4" | Not allowed | Same as stud spacing | |
Vinyl siding (see Section 703.11) | 0.035 | Lap | 0.120 " nail (shank) with a 0.313 " head or 16-gage staple with3/8- to 1/2-inch crownh, i | 0.120 " nail (shank) with a 0.313 " head or 16-gage staple with 3/8- to 1/2-inch crown h | 0.120 " nail (shank) with a 0.313 " head or 16-gage staple with 3/8- to 1/2-inch crown h | 0.120 "nail (shank) with a 0.313 head Section 703.11.2 | Not allowed | 16 inches on center or as specified by the manufacturer instructions or test report | |
Wood siding (see Section 703.5 ) | Wood rustic, drop | 3/8 min. | Lap | 6d box or siding nail (2"x 0.099 ") | 6d box or siding nail (2"x 0.099 ") | 6d box or siding nail (2"x 0.099 ") | 6d box or siding nail (2"x 0.099 ") | 8d box or siding nail (21/2" 0.113 ") Staple-2" | Face nailing up to 6" widths, 1 nail per bearing; 8" widths and over, 2 nails per bearing |
Shiplap | 19/32 average | Lap | |||||||
Bevel | 7/16 | ||||||||
Butt tip | 3/16 | Lap | |||||||
Wood structural panel ANSI/APA PRP-210 siding (exterior grade) (see Section 703.5) | 3/8 -1/2 | Note e | 2"x 0.099 "siding nail | 21/2"x 0.113 " siding nail | 21/2"x 0.113 " siding nail | 21/2"x 0.113 " siding nail | 2"x 0.099 " siding nail | 6" panel edges 12" inter. sup. | |
Wood structural panel lap siding (see Section 703.5) | 3/8 -1/2 | Note e Note g | 2"x 0.099 "siding nail | 21/2"x 0.113 " siding nail | 21/2"x 0.113 " siding nail | 21/2"x 0.113 " siding nail | 2"x 0.099 " siding nail | 8" along bottom edge |
For SI: 1 inch = 25.4 mm.
TABLE 703.3(2)
SCREW FASTENER SUBSTITUTION FOR SIDING ATTACHMENT TO COLD-FORMED STEEL LIGHT FRAME CONSTRUCTIONa, b, c, d, e
NAIL DIAMETER PER TABLE 703.3(1) | MINIMUM SCREW FASTENER SIZE |
0.099 " | No. 6 |
0.113 " | No. 7 |
0.120 " | No. 8 |
For SI: 1 inch = 25.4 mm
TABLE 703.3.2
LIMITS FOR ATTACHMENT PER TABLE 703.3(1)
MAXIMUM MEAN ROOF HEIGHT (feet) | |||
Ultimate Wind Speed (mph 3-second gust) | Exposure | ||
B | C | D | |
115 | NL | 50' | 20' |
120 | NL | 30' | DR |
130 | 60' | 15' | DR |
140 | 35' | DR | DR |
For SI: 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s.
NL = Not Limited by Table 703.3.2, DR = Design Required.
TABLE 703.3.3
OPTIONAL SIDING ATTACHMENT SCHEDULE FOR FASTENERS WHERE NO STUD PENETRATION NECESSARY
APPLICATION | NUMBER AND TYPE OF FASTENER | SPACING OF FASTENERSb |
Exterior wall covering (weighing 3 psf or less) attachment to wood structural panel sheathing, | Ring shank roofing nail ( 0.120 " min. dia.) | 12" o.c. |
either direct or over foam sheathing a maximum of 2 inches thick.a | Ring shank nail ( 0.148 " min. dia.) | 15" o.c. |
No. 6 screw ( 0.138 " min. dia.) | 12" o.c. | |
Note: Does not apply to vertical siding. | No. 8 screw ( 0.164 " min. dia.) | 16" o.c. |
For SI: 1 inch = 25.4 mm, 1 pound per square foot = 0.479 kPa.
Hardboard siding used as architectural trim shall comply with CPA/ANSI A 135.7.
Joints in wood, hardboard or wood structural panel siding shall be made as follows unless otherwise approved. Vertical joints in panel siding shall occur over framing members, unless wood or wood structural panel sheathing is used, and shall be shiplapped or covered with a batten. Horizontal joints in panel siding shall be lapped not less than 1 inch (25 mm) or shall be shiplapped or flashed with Z-flashing and occur over solid blocking, wood or wood structural panel sheathing.
TABLE 703.6.1 MAXIMUM WEATHER EXPOSURE FOR WOOD SHAKES AND SHINGLES ON EXTERIOR WALLSa, b, c
(Dimensions are in inches)
LENGTH | EXPOSURE FOR SINGLE COURSE | EXPOSURE FOR DOUBLE COURSE |
Shinglesa | ||
16 | 7 | 12b |
18 | 8 | 14c |
24 | 101/2 | 16d |
Shakesa | ||
18 | 8 | 14 |
24 | 101/2 | 18 |
For SI: 1 inch = 25.4 mm.
TABLE 703.6.3(1)
SINGLE-COURSE SIDEWALL FASTENERS
SINGLE-COURSE SIDEWALL FASTENERS | |||
Product type | Nail type and minimum length (inches) | Minimum head diameter (inches) | Minimum shank thickness (inches) |
R & R and sanded shingles | |||
16" and 18" shingles | 3d box 11/4 | 0.19 | 0.08 |
24" shingles | 4d box 11/2 | 0.19 | 0.08 |
Grooved shingles | |||
16" and 18" shingles | 3d box 11/4 | 0.19 | 0.08 |
24" shingles | 4d box 11/2 | 0.19 | 0.08 |
Split and sawn shakes | |||
18" straight-split shakes | 5d box 13/4 | 0.19 | 0.08 |
18" and 24" handsplit shakes | 6d box 2 | 0.19 | 0.0915 |
24" tapersplit shakes | 5d box 13/4 | 0.19 | 0.08 |
18" and 24" tapersawn shakes | 6d box 2 | 0.19 | 0.0915 |
For SI: 1 inch = 25.4 mm.
TABLE 703.6.3(2)
DOUBLE-COURSE SIDEWALL FASTENERS
DOUBLE-COURSE SIDEWALL FASTENERS | |||
Product type | Nail type and minimum length (inches) | Minimum head diameter (inches) | Minimum shank thickness (inches) |
R & R and sanded shingles | |||
16", 18" and 24" shingles | 5d box 13/4 or same size casing nails | 0.19 | 0.08 |
Grooved shingles | |||
16", 18" and 24" shingles | 5d box 13/4 | 0.19 | 0.08 |
Split and sawn shakes | |||
18" straight-split shakes | 7d box 21/4 or 8d 21/2 | 0.19 | 0.099 |
18" and 24" handsplit shakes | 7d box 21/4 or 8d 21/2 | 0.19 | 0.099 |
24" tapersplit shakes | 7d box 21/4 or 8d 21/2 | 0.19 | 0.099 |
18" and 24" tapersawn shakes | 7d box 21/4 or 8d 21/2 | 0.19 | 0.099 |
For SI: 1 inch = 25.4 mm.
Exception: Lath is not required over masonry, cast-in-place concrete, precast concrete or stone substrates prepared in accordance with ASTM C1063.
Plaster shall be not less than three coats where applied over metal lath or wire lath and shall be not less than two coats where applied over masonry, concrete, pressure-preservative-treated wood or decay-resistant wood as specified in Section 317.1 or gypsum backing. If the plaster surface is completely covered by veneer or other facing material or is completely concealed, plaster application need be only two coats, provided the total thickness is as set forth in Table 702.1(1).
On wood-frame construction with an on-grade floor slab system, exterior plaster shall be applied to cover, but not extend below, lath, paper and screed.
The proportion of aggregate to cementitious materials shall be as set forth in Table 702.1(3).
Exception: Where the water-resistive barrier that is applied over wood-based sheathing has a water resistance equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, substantially nonwater-absorbing layer or designed drainage space.
Exception:Applications installed in accordance with ASTM C926.
Exceptions:
For SI: 1 inch = 24.5 mm.
FIGURE 703.8
TYPICAL MASONRY VENEER WALL DETAILSe
For SI: 1 inch = 25.4 mm.
FIGURE 703.8 -continued
TYPICAL MASONRY VENEER WALL DETAILSe
TABLE 703.8(1)
STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, WOOD OR STEEL FRAMING, SEISMIC DESIGN CATEGORIES A, B and C
SEISMIC DESIGN CATEGORY | NUMBER OF WOOD- OR STEEL-FRAMED STORIES | MAXIMUM HEIGHT OF VENEER ABOVE NONCOMBUSTIBLE FOUNDATIONa(feet) | MAXIMUM NOMINAL THICKNESS OF VENEER (inches) | MAXIMUM WEIGHT OF VENEER (psf)b | WOOD- OR STEEL-FRAMED STORY |
A or B | Steel: 1 or 2 Wood: 1, 2 or 3 | 30 | 5 | 50 | all |
C | 1 | 30 | 5 | 50 | 1 only |
2 | 30 | top | |||
5 | 50 | bottom | |||
Wood only: 3 | 30 | top | |||
5 | 50 | middle | |||
bottom |
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.479 kPa.
TABLE 703.8(2)
Deleted
The maximum slope of the roof construction without stops shall be 7:12. Roof construction with slopes greater than 7:12 but not more than 12:12 shall have stops of a minimum 3-inch by 3-inch by 1/4-inch (76 mm by 76 mm by 6.4 mm) steel plate welded to the angle at 24 inches (610 mm) on center along the angle or as approved by the building official.
FIGURE 703.8.2.1
EXTERIOR MASONRY VENEER SUPPORT BY STEEL ANGLES
The maximum slope of the roof construction without stops shall be 7:12. Roof construction with slopes greater than 7:12 but not more than 12:12 shall have stops of a minimum 3-inch by 3-inch by 1/4-inch (76 mm by 76 mm by 6.4 mm) steel plate welded to the angle at 24 inches (610 mm) on center along the angle or as approved by the building official.
FIGURE 703.8.2.2
EXTERIOR MASONRY VENEER SUPPORT BY ROOF MEMBERS
TABLE 703.8.3.1
ALLOWABLE SPANS FOR LINTELS SUPPORTING MASONRY VENEERa, b, c, d
SIZE OF STEELANGLEa, c, d (inches) | NO STORY ABOVE | ONE STORY ABOVE | TWO STORIES ABOVE | NO. OF 1/2-INCH OR EQUIVALENT REINFORCING BARS IN REINFORCED LINTELb, d |
3 × 3 × 1/4 | 6'-0" | 4'-6" | 3'-0" | 1 |
4 × 3 × 1/4 | 8'-0" | 6'-0" | 4'-6" | 1 |
5 × 31/2 ×5/16 | 10'-0" | 8'-0" | 6'-0" | 2 |
6 × 31/2 ×5/16 | 14'-0" | 9'-6" | 7'-0" | 2 |
2-6 × 31/2 ×5/16 | 20'-0" | 12'-0" | 9'-6" | 4 |
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm.
TABLE 703.8.3.2
HEIGHT OF MASONRY VENEER ABOVE OPENING
MINIMUM HEIGHT OF MASONRY VENEER ABOVE OPENING (INCH) | MAXIMUM HEIGHT OF MASONRY VENEER ABOVE OPENING (FEET) |
13 | < 5 |
24 | 5 to < 12 |
60 | 12 to height above support allowed by Section 703.8 |
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm.
FIGURE 703.8.3.2
MASONRY VENEER OPENING
TABLE 703.8.4(1)
TIE ATTACHMENT AND AIRSPACE REQUIREMENTS
BACKING AND TIE | MINIMUM TIE | MINIMUM TIE FASTENERa | AIRSPACEc | |
Wood stud backing with corrugated sheet metal | 22 U.S. gage ( 0.0299 in.)×7/8 in. wide | 8d common nail b(21/2 in.× 0.131 in.) | Nominal 1 in. between sheathing and veneer | |
Wood stud backing with metal strand wire | W 1.7 (No. 9 U.S. gage; 0.148 in.) with hook embedded in mortar joint | 8d common nail b(21/2 in.× 0.131 in.) | Minimum nominal 1 in. between sheathing and veneer | Maximum 41/2 in. between backing and veneer |
Cold-formed steel stud backing with adjustable metal strand wire | W 1.7 (No. 9 U.S. gage; 0.148 in.) with hook embedded in mortar joint | No. 10 screw extending through the steel framing a minimum of three exposed threads | Minimum nominal 1 in. between sheathing and veneer | Maximum 41/2 in. between backing and veneer |
For SI: 1 inch = 25.4 mm.
TABLE 703.8.4(2)
REQUIRED BRICK TIE SPACING FOR DIRECT APPLICATION TO WOOD STRUCTURAL PANEL SHEATHING a, b, c
FASTENER TYPEd | SIZE (DIA. OR SCREW #) | REQUIRED BRICK-TIE SPACING (VERTICAL-TIE SPACING/HORIZONTAL-TIE SPACING) (inches/inches) | ||
115 mph V Ultimate | ||||
Zone 5, Exposure B | Zone 5, Exposure C | Zone 5, Exposure D | ||
Ring Shank Nails | 0.091 | 16/16, | ||
16/12, | 16/12, | |||
12/16, | 12/16, | 12/12 | ||
12/12 | 12/12 | |||
0.148 | 24/16, | |||
16/24, | 16/16, | 16/16, | ||
16/16, | 16/12, | 16/12, | ||
16/12, | 12/16, | 12/16, | ||
12/16, 12/12 | 12/12 | 12/12 | ||
Screws | #6 | 24/16, | ||
16/24, | 16/16, | 16/16, | ||
16/16, | 16/12, | 16/12, | ||
16/12, | 12/16, | 12/16, | ||
12/16, 12/12 | 12/12 | 12/12 | ||
24/16, | ||||
16/24, | 16/16, | 16/16, | ||
16/16, | 16/12, | 16/12, | ||
#8 | 16/12, | 12/16, | 12/16, | |
12/16, | 12/12 | 12/12 | ||
12/12 | ||||
#10 | 24/16, | 24/16, | ||
16/24, | 16/24, | 16/16, | ||
16/16, | 16/16, | 16/12, | ||
16/12, | 16/12, | 12/16, | ||
12/16, | 12/16, | 12/12 | ||
12/12 | 12/12 | |||
#14 | 24/16, | 24/16, | 24/16, | |
16/24, | 16/24, | 16/24, | ||
16/16, 16/12, | 16/16, 16/12, | 16/16, 16/12, | ||
12/16, 12/12 | 12/16, 12/12 | 12/16, 12/12 |
For SI: 1 inch = 25.4 mm, 1 mph = 0.447 m/s.
Exception: Deleted
Exterior insulation and finish systems (EIFS) shall comply with this chapter and Section 703.9.1. EIFS with drainage shall comply with this chapter and Section 703.9.2.
Exceptions:
TABLE 703.11.2
ADJUSTED MINIMUM DESIGN WIND PRESSURE REQUIREMENT FOR VINYL SIDING
ULTIMATE DESIGN WIND SPEED (MPH) | ADJUSTED MINIMUM DESIGN WIND PRESSURE (ASD) (PSF)a, b | |||||
Case 1: With interior gypsum wallboardc | Case 2: Without interior gypsum wallboardc | |||||
Exposure | Exposure | |||||
B | C | D | B | C | D | |
110 | - 44.0 | - 61.6 | - 73.1 | - 62.9 | - 88.1 | - 104.4 |
115 | - 49.2 | - 68.9 | - 81.7 | - 70.3 | - 98.4 | - 116.7 |
120 | - 51.8 | - 72.5 | - 86.0 | - 74.0 | - 103.6 | - 122.8 |
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 square foot = 0.0929 m2, 1 mile per hour = 0.447 m/s, 1 pound per square foot = 0.0479 kPa.
Exception: Walls perpendicular to the line used to determine the fire separation distance.
Exceptions:
TABLE 703.15.1
CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
CLADDING FASTENER THROUGH FOAM SHEATHING | CLADDING FASTENER TYPE AND MINIMUM SIZEb | CLADDING FASTENER VERTICAL SPACING (inches) | MAXIMUM THICKNESS OF FOAM SHEATHINGc (inches) | |||||||
16" o.c. Fastener Horizontal Spacing Cladding Weight: | 24" o.c. Fastener Horizontal Spacing Cladding Weight: | |||||||||
3 psf | 11 psf | 18 psf | 25 psf | 3 psf | 11 psf | 18 psf | 25 psf | |||
Wood framing (minimum 11/4-inch penetration) | 0.113 " diameter nail | 6 | 2.00 | 1.45 | 0.75 | DR | 2.00 | 0.85 | DR | DR |
8 | 2.00 | 1.00 | DR | DR | 2.00 | 0.55 | DR | DR | ||
12 | 2.00 | 0.55 | DR | DR | 1.85 | DR | DR | DR | ||
0.120 " diameter nail | 6 | 3.00 | 1.70 | 0.90 | 0.55 | 3.00 | 1.05 | 0.50 | DR | |
8 | 3.00 | 1.20 | 0.60 | DR | 3.00 | 0.70 | DR | DR | ||
12 | 3.00 | 0.70 | DR | DR | 2.15 | DR | DR | DR | ||
0.131 " diameter nail | 6 | 4.00 | 2.15 | 1.20 | 0.75 | 4.00 | 1.35 | 0.70 | DR | |
8 | 4.00 | 1.55 | 0.80 | DR | 4.00 | 0.90 | DR | DR | ||
12 | 4.00 | 0.90 | DR | DR | 2.70 | 0.50 | DR | DR | ||
0.162 " diameter nail | 6 | 4.00 | 3.55 | 2.05 | 1.40 | 4.00 | 2.25 | 1.25 | 0.80 | |
8 | 4.00 | 2.55 | 1.45 | 0.95 | 4.00 | 1.60 | 0.85 | 0.50 | ||
12 | 4.00 | 1.60 | 0.85 | 0.50 | 4.00 | 0.95 | DR | DR |
For SI: 1 inch = 25.4 mm, 1 pound per square foot = 0.0479 kPa, 1 pound per square inch = 6.895 kPa.
DR = Design Required.
o.c. = On Center.
TABLE 703.15.2
FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa, b
FRAMING MEMBER | FASTENER TYPE AND MINIMUM SIZE | MINIMUM PENETRATION INTO WALL FRAMING (inches) | FASTENER SPACING IN FURRING (inches) | MAXIMUM THICKNESS OF FOAM SHEATHINGd (inches) | ||||||||
FURRING MATERIAL | 16'' o.c. Furringe Siding Weight: | 24'' o.c. Furringe Siding Weight: | ||||||||||
3 psf | 11 psf | 18 psf | 25 psf | 3 psf | 11 psf | 18 psf | 25 psf | |||||
Minimum 1X wood furringc | Minimum 2X wood stud | 0.131 " diameter nail | 8 | 4.00 | 2.45 | 1.45 | 0.95 | 4.00 | 1.60 | 0.85 | DR | |
11/4 | 12 | 4.00 | 1.60 | 0.85 | DR | 4.00 | 0.95 | DR | DR | |||
16 | 4.00 | 1.10 | DR | DR | 3.05 | 0.60 | DR | DR | ||||
0.162 " diameter nail | 8 | 4.00 | 4.00 | 2.45 | 1.60 | 4.00 | 2.75 | 1.45 | 0.85 | |||
11/4 | 12 | 4.00 | 2.75 | 1.45 | 0.85 | 4.00 | 1.65 | 0.75 | DR | |||
16 | 4.00 | 1.90 | 0.95 | DR | 4.00 | 1.05 | DR | DR | ||||
No.10 wood screw | 12 | 4.00 | 2.30 | 1.20 | 0.70 | 4.00 | 1.40 | 0.60 | DR | |||
1 | 16 | 4.00 | 1.65 | 0.75 | DR | 4.00 | 0.90 | DR | DR | |||
24 | 4.00 | 0.90 | DR | DR | 2.85 | DR | DR | DR | ||||
1/4" lag screw | 12 | 4.00 | 2.65 | 1.50 | 0.90 | 4.00 | 1.65 | 0.80 | DR | |||
11/2 | 16 | 4.00 | 1.95 | 0.95 | 0.50 | 4.00 | 1.10 | DR | DR | |||
24 | 4.00 | 1.10 | DR | DR | 3.25 | 0.50 | DR | DR |
For SI: 1 inch = 25.4 mm, 1 pound per square foot = 0.0479 kPa, 1 pound per square inch = 6.895 kPa.
DR = Design Required.
o.c. = On Center.
Exceptions:
TABLE 703.16.1
CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
CLADDING FASTENER THROUGH FOAM SHEATHING INTO: | CLADDING FASTENER TYPE AND MINIMUM SIZEb | CLADDING FASTENER VERTICAL SPACING (inches) | MAXIMUM THICKNESS OF FOAM SHEATHINGc (inches) | |||||||
16n o.c. Fastener Horizontal Spacing Cladding Weight: | 24" o.c. Fastener Horizontal Spacing Cladding Weight: | |||||||||
3 psf | 11 psf | 18 psf | 25 psf | 3 psf | 11 psf | 18 psf | 25 psf | |||
Steel framing (minimum penetration of steel thickness + 3 threads) | No. 8 screw into 33-mil steel or thicker | 6 | 3.00 | 2.95 | 2.20 | 1.45 | 3.00 | 2.35 | 1.25 | DR |
8 | 3.00 | 2.55 | 1.60 | 0.60 | 3.00 | 1.80 | DR | DR | ||
12 | 3.00 | 1.80 | DR | DR | 3.00 | 0.65 | DR | DR | ||
No. 10 screw into 33-mil steel | 6 | 4.00 | 3.50 | 2.70 | 1.95 | 4.00 | 2.90 | 1.70 | 0.55 | |
8 | 4.00 | 3.10 | 2.05 | 1.00 | 4.00 | 2.25 | 0.70 | DR | ||
12 | 4.00 | 2.25 | 0.70 | DR | 3.70 | 1.05 | DR | DR | ||
No. 10 screw into 43-mil steel or thicker | 6 | 4.00 | 4.00 | 4.00 | 3.60 | 4.00 | 4.00 | 3.45 | 2.70 | |
8 | 4.00 | 4.00 | 3.70 | 3.00 | 4.00 | 3.85 | 2.80 | 1.80 | ||
12 | 4.00 | 3.85 | 2.80 | 1.80 | 4.00 | 3.05 | 1.50 | DR |
For SI: 1 inch = 25.4 mm, 1 mil = 0.0254 mm, 1 pound per square foot = 0.0479 kPa, 1 pound per square inch = 6.895 kPa.
DR = Design Required.
o.c. = On Center.
TABLE 703.16.2
FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
FRAMING MEMBER | FASTENER TYPE AND MINIMUM SIZEb | MINIMUM PENETRATION INTO WALL FRAMING (inches) | FASTENER SPACING IN FURRING (inches) | MAXIMUM THICKNESS OF FOAM SHEATHINGd (inches) | ||||||||
FURRING MATERIAL | 16no.c. Furring e Cladding Weight: | 24no.c. Furring e Cladding Weight: | ||||||||||
3 psf | 11 psf | 18 psf | 25 psf | 3 psf | 11 psf | 18 psf | 25 psf | |||||
Minimum 33-mil steel furring or minimum 1x wood furringc | 33-mil steel stud | No. 8 screw | Steel thickness + 3 threads | 12 | 3.00 | 1.80 | DR | DR | 3.00 | 0.65 | DR | DR |
16 | 3.00 | 1.00 | DR | DR | 2.85 | DR | DR | DR | ||||
24 | 2.85 | DR | DR | DR | 2.20 | DR | DR | DR | ||||
No. 10 screw | Steel thickness + 3 threads | 12 | 4.00 | 2.25 | 0.70 | DR | 3.70 | 1.05 | DR | DR | ||
16 | 3.85 | 1.45 | DR | DR | 3.40 | DR | DR | DR | ||||
24 | 3.40 | DR | DR | DR | 2.70 | DR | DR | DR | ||||
43-mil or thicker steel stud | No. 8 Screw | Steel thickness + 3 threads | 12 | 3.00 | 1.80 | DR | DR | 3.00 | 0.65 | DR | DR | |
16 | 3.00 | 1.00 | DR | DR | 2.85 | DR | DR | DR | ||||
24 | 2.85 | DR | DR | DR | 2.20 | DR | DR | DR | ||||
Steel thickness + 3 threads | 12 | 4.00 | 3.85 | 2.80 | 1.80 | 4.00 | 3.05 | 1.50 | DR | |||
No. 10 | 16 | 4.00 | 3.30 | 1.95 | 0.60 | 4.00 | 2.25 | DR | DR | |||
24 | 4.00 | 2.25 | DR | DR | 4.00 | 0.65 | DR | DR |
For SI: 1 inch = 25.4 mm, 1 mil = 0.0254 mm, 1 pound per square foot = 0.0479 kPa, 1 pound per square inch = 6.895 kPa.
DR = Design Required.
o.c. = On Center.
Exceptions:
Replaces: 4101:8-7-01
Ohio Admin. Code 4101:8-7-01
Five Year Review (FYR) Dates: 07/01/2024
Promulgated Under: 119.03
Statutory Authority: 3781.10(A)(1)
Rule Amplifies: 3781.01, 4740.14, 3791.04, 3781.11, 3781.10, 3781.06
Prior Effective Dates: 01/01/2013