Referenced Code | Ohio Administrative Code Chapters |
Ohio Building Code | 4101:1-1 to 4101:1-35 |
Fire Code | 1301:7-1 to 1301:7-7 |
Mechanical Code | 4101:2-1 to 4101:2-15 |
Plumbing Code | 4101:3-1 to 4101:3-15 |
AAMA | American Architectural Manufacturers Association 1827 Walden Office Square, Suite 550 Schaumburg, IL 60173 |
Standard Referenced | Title |
AAMA/WDMA/CSA 101/ | North American Fenestration Standards/ |
I.S.2/ A440-17: | Specifications for Windows, Doors and Skylights |
450-10: | Voluntary Performance Rating Method for Mulled Fenestration Assemblies |
506-16: | Voluntary Specifications for Hurricane Impact and Cycle Testing of Fenestration Products |
711-13: | Voluntary Specification for Self-adhering Flashing Used for Installation of Exterior Wall Fenestration Products |
712-14: | Voluntary Specification for Mechanically Attached Flexible Flashing |
714-15: | Voluntary Specification for Liquid Applied Flashing Used to Create a Water-resistive Seal around Exterior Wall Openings in Buildings |
AAMA/NPEA/NSA 2100-12: | Specifications for Sunrooms |
ACCA | Air Conditioning Contractors of America 2800 Shirlington Road, Suite 300 Arlington, VA 22206 |
Standard referenced | Title |
Manual D-2016: | Residential Duct Systems |
Manual J-2016: | Residential Load Calculation-Eighth Edition |
Manual S-2014: | Residential Equipment Selection |
ACI | American Concrete Institute 38800 Country Club Drive Farmington Hills, MI 48331 |
Standard referenced | Title |
318-14: | Building Code Requirements for Structural Concrete |
332-14: | Residential Code Requirements for Structural Concrete |
AISI | American Iron and Steel Institute 25 Massachusetts Avenue, NW Suite 800 Washington, DC 20001 |
Standard referenced | Title |
AISI S100-16: | North American Specification for the Design of Cold-formed Steel Structural Members, 2016 |
AISI S220-15: | North American Standard for Cold-formed Steel Framing-Nonstructural Members, 2015 |
AISI S230-15: | Standard for Cold-formed Steel Framing- Prescriptive Method for One- and Two-family Dwellings, 2015 |
AISI S240-15: | North American Standard for Cold-Formed Steel Structural Framing |
AMCA | Air Movement and Control Association International 30 West University Drive Arlington Heights, IL 60004 |
Standard referenced | Title |
ANSI/AMCA 210- ANSI/ASHRAE 51-07: | Laboratory Methods of Testing Fans for Aerodynamic Performance Rating |
ANSI | American National Standards Institute 25 West 43rd Street, 4th Floor New York, NY 10036 |
Standard referenced | Title |
A108.1A-17: | Installation of Ceramic Tile in the Wet-set Method, with Portland Cement Mortar |
A108.1B-17: | Installation of Ceramic Tile, Quarry Tile on a Cured |
Portland Cement Mortar Setting Bed with Dry-set or Latex Portland Mortar | |
A108.4-17: | Installation of Ceramic Tile with Organic Adhesives or Water-Cleanable Tile-setting Epoxy Adhesive |
A108.5-17: | Installation of Ceramic Tile with Dry-set Portland Cement Mortar or Latex Portland Cement Mortar |
A108.6-17: | Installation of Ceramic Tile with Chemicalresistant, Water-cleanable Tile-setting and -grouting Epoxy |
A108.11-17: | Interior Installation of Cementitious Backer Units |
ANSI 117-2015: | Standard Specifications for Structural Glued Laminated Timber of Softwood Species |
A118.1-17: | American National Standard Specifications for Dryset Portland Cement Mortar |
A118.3-13: | American National Standard Specifications for Chemical-resistant, Water-cleanable Tile-setting and -grouting Epoxy, and Water-cleanable Tilesetting Epoxy Adhesive |
A118.4-16: | American National Standard Specifications for Modified Dry-Set Cement Mortar |
A 118.10 -17: | Specification for Load-bearing, Bonded, Waterproof Membranes for Thin-set Ceramic Tile and Dimension Stone Installation |
A136.1-17: | American National Standard Specifications for Organic Adhesives for Installation of Ceramic Tile |
A137.1-17: | American National Standard Specifications for Ceramic Tile |
LC1/CSA 6.26-18: | Fuel Gas Piping Systems Using Corrugated Stainless Steel Tubing (CSST) |
LC4/CSA 6.32-12: | Press-connect Metallic Fittings for Use in Fuel Gas Distribution Systems |
Z21.1-2010: | Household Cooking Gas Appliances |
Z21.5.1/ CSA 7.1-14: | Gas Clothes Dryers- Volume I-Type I Clothes Dryers |
Z21.8-94 (R2002): | Installation of Domestic Gas Conversion Burners |
Z21.10.1/ CSA 4.1-12: | Gas Water Heaters-Volume I-Storage Water Heaters with Input Ratings of 75,000 Btu per hour or Less |
Z21.10.3/ CSA 4.3-11: | Gas Water Heaters-Volume III-Storage Water Heaters with Input Ratings above 75,000 Btu per hour, Circulating and Instantaneous |
Z21.11.2-11: | Gas-fired Room Heaters-Volume II-Unvented Room Heaters |
Z21.13/ CSA 4.9-11: | Gas-fired Low-pressure Steam and Hot Water Boilers |
Z21.15/ CSA 9.1-09: | Manually Operated Gas Valves for Appliances, Appliance Connector Valves and Hose End Valves |
Z21.22-99 (R2015): | Relief Valves for Hot Water Supply Systems-with Addenda Z21.22a-2000 (R2003) and 21.22b- 2001 (R2003) |
Z21.24/ CSA 6.10-06: | Connectors for Gas Appliances |
Z21.40.1/ | Gas-fired, Heat-activated Air-conditioning and Heat |
CSA 2.91-96 (R2011): | Pump Appliances |
Z21.40.2/ | Air-conditioning and Heat Pump Appliances |
CSA 2.92-96 (R2011): | (Thermal Combustion) |
Z21.42-2014: | Gas-fired Illuminating Appliances |
Z21.47/ CSA 2.3-12: | Gas-fired Central Furnaces |
Z21.50/ CSA 2.22-16: | Vented Gas Fireplaces |
Z21.54-2009: | Gas Hose Connectors for Portable Outdoor Gas-fired Appliances |
Z21.56/ CSA 4.7-17: | Gas-fired Pool Heaters |
Z21.58-18/ CSA 1.6-18: | Outdoor Cooking Gas Appliances |
Z21.60/ CSA 2.26-12: | Decorative Gas Appliances for Installation in Solid Fuel-burning Fireplaces |
Z21.69/ CSA 6.16-09: | Connectors for Movable Gas Appliances |
Z21.75/ CSA 6.27-07: | Connectors for Outdoor Gas Appliances and Manufactured Homes |
Z21.80/ CSA 6.22-11: | Line Pressure Regulators |
ANSI/ CSA FC 1-12: | Stationary Fuel Cell Power Systems |
Z21.84-12: | Manually Listed, Natural Gas Decorative Gas Appliances for Installation in Solid Fuel-burning Fireplaces |
Z21.86/ CSA 2.32-08: | Gas-fired Vented Space Heating Appliances |
Z21.88/ CSA 2.33-16: | Vented Gas Fireplace Heaters |
Z21.91-07: | Ventless Firebox Enclosures for Gas-fired Unvented Decorative Room Heaters |
Z21.93/ CSA 6.30-13: | Excess Flow Valves for Natural and LP Gas with Pressures up to 5 psig |
Z21.97-12: | Outdoor Decorative Appliances |
Z83.6-90 (R1998): | Gas-fired Infrared Heaters |
Z83.8/ CSA 2.6-09: | Gas-fired Unit Heaters, Gas Packaged Heaters, Gas Utility Heaters and Gas-fired Duct Furnaces |
Z83.19-01 (R2009): | Gas-fuel High-intensity Infrared Heaters |
Z83.20-08: | Gas-fired Low-intensity Infared Heaters Outdoor Decorative Appliances |
Z97.1-2014: | Safety Glazing Materials Used in Buildings- Safety Performance Specifications and Methods of Test |
APA | APA-The Engineered Wood Association 7011 South 19th Tacoma, WA 98466 |
Standard referenced | Title |
ANSI/A190.1-2017: ANSI/ | Structural Glued-laminated Timber Standard for Performance-rated Engineered Wood |
APA PRP 210-2014: ANSI/ | Siding Standard for Performance-rated Cross Laminated |
APA PRG 320-2017: ANSI/ | Timber Standard for Performance-rated Engineered Wood |
APA PRR 410-2016: ANSI/ | Rim Boards Standard for Performance-Rated Structural |
APA PRS 610.1-2013: | Insulated Panels in Wall Applications |
APA E30-15: | Engineered Wood Construction Guide |
ASCE/SEI | American Society of Civil Engineers Structural Engineering Institute 1801 Alexander Bell Drive Reston, VA 20191-4400 |
Standard referenced | Title |
7-16: | Minimum Design Loads and Associated Criteria for Buildings and Other Structures |
24-14: | Flood-resistant Design and Construction |
32-01: | Design and Construction of Frost-protected Shallow Foundations |
ASHRAE | ASHRAE 1791 Tullie Circle NE Atlanta, GA 30329 |
Standard referenced | Title |
ASHRAE-2001: | 2001 ASHRAE Handbook of Fundamentals for use in reference to Table 1105.5.2 (1) only |
ASHRAE-2017: | ASHRAE Handbook of Fundamentals |
ASHRAE 193-2010 (RA 2014): | Method of Test for Determining Air Tightness of HVAC Equipment |
34-2022: | Designation and Safety Classification of Refrigerants |
ASME | American Society of Mechanical Engineers Two Park Avenue New York, NY 10016-5990 |
Standard referenced | Title |
ASME A17.1-2016/CSA B44-16: | Safety Code for Elevators and Escalators |
A18.1-2014: | Safety Standard for Platforms and Stairway Chair Lifts |
B1.20.1-2013: | Pipe Threads, General-purpose (Inch) |
B16.33-2012: | Manually Operated Metallic Gas Valves for Use in Gas Piping Systems up to 125 psig (Sizes 1/2 through 2) |
B16.44-2012: | Manually Operated Metallic Gas Valves for Use in Above-ground Piping Systems up to 5 psi |
B36.10M-2004(R2015): | Welded and Seamless Wrought-steel Pipe |
BPVC-2015: | ASME Boiler and Pressure Vessel Code (Sections I, II, IV, V, VI and VIII) |
CSD-1-2016: | Controls and Safety Devices for Automatically Fired Boilers |
ASTM | ASTM International 100 Barr Harbor Drive, P.O. Box C700 West Conshohocken, PA 19428 |
Standard referenced | Title |
A36/A36M-14: | Specification for Carbon Structural Steel |
A53/A53M-12: | Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded and Seamless |
A106/A106M-14: | Specification for Seamless Carbon Steel Pipe for High-temperature Service |
A123/A123M-15: | Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products |
A153/A153M-09: | Specification for Zinc Coating (Hot Dip) on Iron and Steel Hardware |
A167-99(2009): | Specification for Stainless and Heat-resisting Chromium-nickel Steel Plate, Sheet and Strip |
A240/A240M-15A: | Standard Specification for Chromium and Chromium-nickel Stainless Steel Plate, Sheet and Strip for Pressure Vessels and for General Applications |
A254-12: | Specification for Copper Brazed Steel Tubing |
A268-2010: | Standard Specification for Seamless and Welded Ferritic and Martensitic Stainless Steel Tubing for General Service |
A269-2015: | Standard Specification for Seamless and Welded Austenitic Stainless Steel Tubing for General Service |
A307-14: | Specification for Carbon Steel Bolts and Studs, 60,000 psi Tensile Strength |
A463/A463M-15: | Standard Specification for Steel Sheet, Aluminum-coated by the Hot-dip Process |
A539-99: | Specification for Electric-resistance-welded Coiled Steel Tubing for Gas and Fuel Oil Lines |
A563-15: | Standard Specification for Carbon and Alloy Steel Nuts |
A615/A615M-2015aE1: | Specification for Deformed and Plain Carbon-steel Bars for Concrete Reinforcement |
A641/A641M-09a(2014): | Specification for Zinc-coated (Galvanized) Carbon Steel Wire |
A653/A653M-15: | Specification for Steel Sheet, Zinc-coated (Galvanized) or Zinc-iron Alloy-coated (Galvannealed) by the Hot-dip Process |
A706/A706M-15: | Specification for Low-alloy Steel Deformed and Plain Bars for Concrete Reinforcement |
A755/A755M-2015: | Specification for Steel Sheet, Metallic Coated by the Hot-dip Process and Prepainted by the Coil-coating Process for Exterior Exposed Building Products |
A792/A792M-10(2015): | Specification for Steel Sheet, 55% Aluminumzinc Alloy-coated by the Hot-dip Process |
A875/A875M-13: | Specification for Steel Sheet, Zinc-5%, Aluminum Alloy-coated by the Hot-dip Process |
A924/A924M-14: | Standard Specification for General Requirements for Steel Sheet, Metallic-coated by the Hot-dip Process |
A996/A996M-15: | Specifications for Rail-steel and Axle-steel Deformed Bars for Concrete Reinforcement |
A1003/A1003M-15: | Standard Specification for Steel Sheet, Carbon, Metallic and Nonmetallic-coated for Cold-formed Framing Members |
B42-2015A: | Specification for Seamless Copper Pipe, Standard Sizes |
B43-15: | Specification for Seamless Red Brass Pipe, Standard Sizes |
B75/B75M-11: | Specification for Seamless Copper Tube |
B88-14: | Specification for Seamless Copper Water Tube |
B101-12: | Specification for Lead-coated Copper Sheet and Strip for Building Construction |
B135-10: | Specification for Seamless Brass Tube |
B209-14: | Specification for Aluminum and Aluminum-alloy Sheet and Plate |
B251-10: | Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube |
B302-12: | Specification for Threadless Copper Pipe, Standard Sizes |
B306-13: | Specification for Copper Drainage Tube (DWV) |
B370-12: | Specification for Copper Sheet and Strip for Building Construction |
B695-04(2009): | Standard Specification for Coatings of Zinc Mechanically Deposited on Iron and Steel |
B813-10: | Specification for Liquid and Paste Fluxes for Soldering Applications of Copper and Copper Alloy Tube |
B828-02(2010): | Practice for Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings |
C5-10: | Specification for Quicklime for Structural Purposes |
C22/C22M-2015: | Specification for Gypsum |
C27-98(2013): | Specification for Standard Classification of Fireclay and High-alumina Refractory Brick |
C28/C28M-10(2015): | Specification for Gypsum Plasters |
C33/C33M-13: | Specification for Concrete Aggregates |
C34-13: | Specification for Structural Clay Load-bearing Wall Tile |
C35/C35M-(2014): | Specification for Inorganic Aggregates for Use in Gypsum Plaster |
C55-2014A: | Specification for Concrete Building Brick |
C56-13: | Standard Specification for Structural Clay Nonloadbearing Tile |
C59/C59M-00(2015): | Specification for Gypsum Casting Plaster and Molding Plaster |
C61/C61M-00(2015): | Specification for Gypsum Keene's Cement |
C62-13A: | Standard Specification for Building Brick (Solid Masonry Units Made from Clay or Shale) |
C73-14: | Specification for Calcium Silicate Face Brick (Sand Lime Brick) |
C90-14: | Specification for Load-bearing Concrete Masonry Units |
C91/C91M-12: | Specification for Masonry Cement |
C94/C94M-15A: | Standard Specification for Ready-mixed Concrete |
C126-15: | Standard Specification for Ceramic Glazed Structural Clay Facing Tile, Facing Brick, and Solid Masonry Units |
C129-14A: | Specification for Nonload-bearing Concrete Masonry Units |
C143/C143M-15: | Test Method for Slump of Hydraulic Cement Concrete |
C145-85: | Specification for Solid Load-bearing Concrete Masonry Units |
C150/C150M-15: | Specification for Portland Cement |
C199-84(2011): | Test Method for Pier Test for Refractory Mortar |
C203-05a(2012): | Standard Test Methods for Breaking Load and Flexural Properties of Block-type Thermal Insulation |
C207-06(2011): | Specification for Hydrated Lime for Masonry Purposes |
C208-12: | Specification for Cellulosic Fiber Insulating Board |
C212-14: | Standard Specification for Structural Clay Facing Tile |
C216-15: | Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale) |
C270-14A: | Specification for Mortar for Unit Masonry |
C315-07(2011): | Specification for Clay Flue Liners and Chimney Pots |
C406/C406M-2015: | Specifications for Roofing Slate |
C411-11: | Test Method for Hot-surface Performance of High-temperature Thermal Insulation |
C475/C475M-15: | Specification for Joint Compound and Joint Tape for Finishing Gypsum Wallboard |
C476-10: | Specification for Grout for Masonry |
C503/C503M-2010: | Standard Specification for Marble Dimension Stone |
C514-04(2014): | Specification for Nails for the Application of Gypsum Wallboard |
C552-15: | Standard Specification for Cellular Glass Thermal Insulation |
C557-03(2009)e01: | Specification for Adhesives for Fastening Gypsum Wallboard to Wood Framing |
C568/C568M-2010: | Standard Specification for Limestone Dimension Stone |
C578-15: | Specification for Rigid, Cellular Polystyrene Thermal Insulation |
C587-04(2014): | Specification for Gypsum Veneer Plaster |
C595/C595M-14E1: | Specification for Blended Hydraulic Cements |
C615/C615M-11: | Standard Specification for Granite Dimension Stone |
C616/C616M-10: | Standard Specification for Quartz-based Dimension Stone |
C629/C629M-10: | Standard Specification for Slate Dimension Stone |
C631-09(2014): | Specification for Bonding Compounds for Interior Gypsum Plastering |
C645-14: | Specification for Nonstructural Steel Framing Members |
C652-15: | Specification for Hollow Brick (Hollow Masonry Units Made from Clay or Shale) |
C685/C685M-14: | Specification for Concrete Made by Volumetric Batching and Continuous Mixing |
C726-12: | Standard Specification for Mineral Wool Roof Insulation Board |
C728-15: | Standard Specification for Perlite Thermal Insulation Board |
C744-14: | Standard Specification for Prefaced Concrete and Calcium Silicate Masonry Units |
C836/C836M-15: | Specification for High Solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane for Use with Separate Wearing Course |
C841-03(2013): | Standard Specification for Installation of Interior Lathing and Furring |
C842-05(2015): | Standard Specification for Application of Interior Gypsum Plaster |
C843-99(2012): | Specification for Application of Gypsum Veneer Plaster |
C844-2015: | Specification for Application of Gypsum Base to Receive Gypsum Veneer Plaster |
C847-14A: | Specification for Metal Lath |
C887-13: | Specification for Packaged, Dry, Combined Materials for Surface Bonding Mortar |
C897-15: | Specification for Aggregate for Job-mixed Portland Cement-based Plasters |
C920-14A: | Standard Specification for Elastomeric Joint Sealants |
C926-15B: | Specification for Application of Portland Cement-based Plaster |
C933-14: | Specification for Welded Wire Lath |
C946-10: | Standard Practice for Construction of Dry-Stacked, Surface-Bonded Walls |
C954-15: | Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs from 0.033 in (0.84 mm) or to 0.112 in. (2.84 mm) in Thickness |
C957/C957M-15: | Specification for High-solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane for Use with Integral Wearing Surface |
C1002-14: | Specification for Steel Self-piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs |
C1029-15: | Specification for Spray-applied Rigid Cellular Polyurethane Thermal Insulation |
C1032-14: | Specification for Woven Wire Plaster Base |
C1047-14a: | Specification for Accessories for Gypsum Wallboard and Gypsum Veneer Base |
C1063-15A: | Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-based Plaster |
C1088-14: | Standard Specification for Thin Veneer Brick Units Made from Clay or Shale |
C1107/C1107M-14A: | Standard Specification for Packaged Dry, Hydraulic-cement Grout (Nonshrink) |
C1116/C116M-10(2015): | Standard Specification for Fiber-reinforced Concrete and Shotcrete |
C1157-11/C1157M-11: | Standard Performance Specification for Hydraulic Cement |
C1167-11: | Specification for Clay Roof Tiles |
C1177/C1177M-13: | Specification for Glass Mat Gypsum Substrate for Use as Sheathing |
C1178/C1178M-13: | Specification for Glass Mat Water-resistant Gypsum Backing Panel |
C1186-08(2012): | Specification for Flat Fiber Cement Sheets |
C1261-13: | Specification for Firebox Brick for Residential Fireplaces |
C1278/C1278M-07a(2011): | Specification for Fiber-reinforced Gypsum Panels |
C1283-11: | Practice for Installing Clay Flue Lining |
C1288-14: | Standard Specification for Discrete Nonasbestos Fiber-cement Interior Substrate Sheets |
C1289-15: | Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board |
C1325-14: | Standard Specification for Nonasbestos Fibermat Reinforced Cement Interior Substrate Sheets Backer Units |
C1328/C1328M-12: | Specification for Plastic (Stucco) Cement |
C1363-11: | The Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus |
C1364-10B: | Standard Specification for Architectural Cast Stone |
C1396/C1396M-2014A: | Specification for Gypsum Board |
C1405-15: | Standard Specification for Glazed Brick (Single Fired, Brick Units) |
C1492-03(2009): | Specification for Concrete Roof Tile |
C1513-2013: | Standard Specification for Steel Tapping Screws for Cold-formed Steel Framing Connections |
C1634-15: | Standard Specification for Concrete Facing Brick |
C1658/C1658M-13: | Standard Specification for Glass Mat Gypsum Panels |
C1668-13a: | Standard Specification for Externally Applied Reflective Insulation Systems on Rigid Duct in Heating, Ventilation, and Air Conditioning (HVAC) Systems |
C1670/1670M-16: | Standard Specification for Adhered Manufactured Stone Masonry Veneer Units |
C1691-11: | Standard Specification for Unreinforced Autoclaved Aerated Concrete (AAC) Masonry Units |
C1693-11: | Standard Specification for Autoclaved Aerated Concrete (AAC) |
C1766-13: | Standard Specification for Factory-Laminated Gypsum Panel Products |
D41/D41M-2011: | Specification for Asphalt Primer Used in Roofing, Dampproofing and Waterproofing |
D43/D43M-2000(2012)E1: | Specification for Coal Tar Primer Used in Roofing, Dampproofing and Waterproofing |
D226/D226M-09: | Specification for Asphalt-saturated (Organic Felt) Used in Roofing and Waterproofing |
D227/D227M-03(2011)e1: | Specification for Coal Tar Saturated (Organic Felt) Used in Roofing and Waterproofing |
D312/D321M-15: | Specification for Asphalt Used in Roofing |
D422-63(2007)E2: | Test Method for Particle-size Analysis of Soils |
D449/D449M-03(2014)E1: | Specification for Asphalt Used in Dampproofing and Waterproofing |
D450/D450M-07(2013)E1: | Specification for Coal-tar Pitch Used in Roofing, Dampproofing and Waterproofing |
D1227-13: | Specification for Emulsified Asphalt Used as a Protective Coating for Roofing |
D1248-12: | Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable |
D1693-15: | Test Method for Environmental Stress-cracking of Ethylene Plastics |
D1784-11: | Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlorinated Poly (Vinyl Chloride) (CPVC) Compounds |
D1863/D1863M-05(2011)e1: | Specification for Mineral Aggregate Used in Built-up Roofs |
D1970/D1970M-2015A: | Specification for Self-adhering Polymer Modified Bitumen Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection |
D2178/D2178M-15: | Specification for Asphalt Glass Felt Used in Roofing and Waterproofing |
D2412-11: | Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-plate Loading |
D2447-03: | Specification for Polyethylene (PE) Plastic Pipe Schedules 40 and 80, Based on Outside Diameter |
D2513-2014e1: | Specification for Gas Pressure Pipe, Tubing and Fittings |
D2626/D2626M-04 (2012)e1: | Specification for Asphalt-saturated and Coated Organic Felt Base Sheet Used in Roofing |
D2683-14: | Specification for Socket-type Polyethylene Fittings for Outside Diameter-controlled Polyethylene Pipe and Tubing |
D2822/D2822M-05(2011)e1: | Specification for Asphalt Roof Cement, Asbestos Containing |
D2823/D2823M-05(2011)e1: | Specification for Asphalt Roof Coatings, Asbestos Containing |
D2824/D2824M-2013: | Specification for Aluminum-pigmented Asphalt Roof Coatings, Nonfibered, Asbestos Fibered and Fibered without Asbestos |
D2898-10: | Test Methods for Accelerated Weathering of Fire-retardant-treated Wood for Fire Testing |
D3019-08: | Specification for Lap Cement Used with Asphalt Roll Roofing, Nonfibered, Asbestos Fibered and Nonasbestos Fibered |
D3161/D3161M-15: | Test Method for Wind-Resistance of Steep Slope Roofing Products (Fan Induced Method) |
D3201/D3201M-2013: | Test Method for Hygroscopic Properties of Fireretardant Wood and Wood-base Products |
D3309-96a(2002): | Specification for Polybutylene (PB) Plastic Hot-and Cold-water Distribution System |
D3350-14: | Specification for Polyethylene Plastic Pipe and Fitting Materials |
D3462/D3462M-10A: | Specification for Asphalt Shingles Made From Glass Felt and Surfaced with Mineral Granules |
D3468/D3468M-99(2013)E1: | Specification for Liquid-applied Neoprene and Chlorosulfanated Polyethylene Used in Roofing and Waterproofing |
D3679-13: | Specification for Rigid Poly (Vinyl Chloride) (PVC) Siding |
D3737-2012: | Practice for Establishing Allowable Properties for Structural Glued Laminated Timber (Glulam) |
D3747-79(2007): | Specification for Emulsified Asphalt Adhesive for Adhering Roof Insulation |
D3909/D3909M-14: | Specification for Asphalt Roll Roofing (Glass Felt) Surfaced with Mineral Granules |
D4022/D4022M-2007(2012)e1: | Specification for Coal Tar Roof Cement, Asbestos Containing |
D4318-10E1: | Test Methods for Liquid Limit, Plastic Limit and Plasticity Index of Soils |
D4434/D4434M-12: | Specification for Poly (Vinyl Chloride) Sheet Roofing |
D4479/D4479M-07(2012)e1: | Specification for Asphalt Roof Coatings- asbestos-free |
D4586/D4586M-07(2012)e1: | Specification for Asphalt Roof Cemen- asbestos-free |
D4601/D4601M-04(2012)e1: | Specification for Asphalt-coated Glass Fiber Base Sheet Used in Roofing |
D4637/D4637M-14E1: | Specification for EPDM Sheet Used in Singleply Roof Membrane |
D4829-11: | Test Method for Expansion Index of Soils |
D4869/D4869M-15: | Specification for Asphalt-saturated (Organic Felt) Underlayment Used in Steep Slope Roofing |
D4897/D4897M-01(2009): | Specification for Asphalt Coated Glass-fiber Venting Base Sheet Used in Roofing |
D4990-1997a(2013): | Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing |
D5019-07a: | Specification for Reinforced Nonvulcanized Polymeric Sheet Used in Roofing Membrane |
D5055-13E1: | Specification for Establishing and Monitoring Structural Capacities of Prefabricated Wood I-joists |
D5456-14B: | Standard Specification for Evaluation of Structural Composite Lumber Products |
D5516-09: | Test Method for Evaluating the Flexural Properties of Fire-retardant-treated Softwood Plywood Exposed to the Elevated Temperatures |
D5643/D5643M-06(2012)e1: | Specification for Coal Tar Roof Cement Asbestos-free |
D5664-10: | Test Methods For Evaluating the Effects of Fire-retardant Treatments and Elevated Temperatures on Strength Properties of Fireretardant-treated Lumber |
D5665/D5665M-99a(2014)E1: | Specification for Thermoplastic Fabrics Used in Cold-applied Roofing and Waterproofing |
D5726-98(2013): | Specification for Thermoplastic Fabrics Used in Hot-applied Roofing and Waterproofing |
D6083-05e01: | Specification for Liquid-applied Acrylic Coating Used in Roofing |
D6162/D6162M-2000a(2015)E1: | Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements |
D6163/D6163M-2000(2015)E1: | Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using Glass Fiber Reinforcements |
D6164/D6164M-11: | Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using Polyester Reinforcements |
D6222/D6222M-11: | Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using Polyester Reinforcements |
D6223/D6223M-02(2009)E1: | Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcement |
D6298-13: | Specification for Fiberglass-reinforced Styrene Butadiene Styrene (SBS) Modified Bituminous Sheets with a Factory Applied Metal Surface |
D6305-08(2015)E1: | Practice for Calculating Bending Strength Design Adjustment Factors for Fire-retardant-treated Plywood Roof Sheathing |
D6380/D6380-03(2013)E1: | Standard Specification for Asphalt Roll Roofing (Organic Felt) |
D6464-03a(2009)e1: | Standard Specification for Expandable Foam Adhesives for Fastening Gypsum Wallboard to Wood Framing |
D6694/D6694M-08(2013)E1: | Standard Specification for Liquid-applied Silicone Coating Used in Spray Polyurethane Foam Roofing Systems |
D6754/D6754M-10: | Standard Specification for Ketone-ethyleneester-based Sheet Roofing |
D6757-2013: | Specification for Underlayment Felt Containing Inorganic Fibers Used with Steep Slope Roofing |
D6841-08: | Standard Practice for Calculating Design Value Treatment Adjustment Factors for Fireretardant-treated Lumber |
D6878/D6878M-13: | Standard Specification for Thermoplastic-polyolefin-based Sheet Roofing |
D6947/D6947M-07(2013)E1: | Standard Specification for Liquid Applied Moisture Cured Polyurethane Coating Used in Spray Polyurethane Foam Roofing System |
D7032-14: | Standard Specification for Establishing Performance Ratings for Wood-plastic Composite Deck Boards and Guardrail Systems (Guards or Handrails) |
D7158-D7158M-2016: | Standard Test Method for Wind Resistance of Asphalt Shingles (Uplift Force/Uplift Resistance Method) |
D7254-15: | Standard Specification for Polypropylene (PP) siding |
D7425/D7425M-13: | Standard Specification for Spray Polyurethane Foam Used for Roofing Application |
D7672-14: | Standard Specification for Evaluating Structural Capacities of Rim Board Products and Assemblies |
D7793-13: | Standard Specification for Insulated Vinyl Siding |
E84-2016: | Standard Test Method for Surface Burning Characteristics of Building Materials |
E96/E96M-2015: | Test Method for Water Vapor Transmission of Materials |
E108-2016: | Test Methods for Fire Tests of Roof Coverings |
E119-2016: | Test Methods for Fire Tests of Building Construction and Materials |
E136-2016: | Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C |
E283-04(2012): | Test Method for Determining the Rate of Air Leakage through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences across the Specimen |
E330/E330M-14: | Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference |
E331-00(2009): | Test Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by Uniform Static Air Pressure Difference |
E779-10: | Standard Test Method for Determining Air Leakage Rate by Fan Pressurization |
E814-2013A: | Standard Test Method for Fire Tests of Penetration Firestop Systems |
E970-14: | Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source |
E1509-12: | Standard Specification for Room Heaters, Pellet Fuel-burning Type |
E1602-03(2010)e1: | Guide for Construction of Solid Fuel Burning Masonry Heaters |
E1827-11: | Standard Test Methods for Determining Airtightness of Building Using an Orifice Blower Door |
E1886-13A: | Test Method for Performance Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials |
E1996-2014a: | Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes |
E2178-2013: | Standard Test Method for Air Permeance of Building Materials |
E2231-15: | Standard Practice for Specimen Preparation and Mounting of Pipe and Duct Insulation Materials to Assess Surface Burning Characteristics |
E2273-03(2011): | Standard Test Method for Determining the Drainage Efficiency of Exterior Insulation and Finish Systems (EIFS) Clad Wall Assemblies |
E2568-09e1: | Standard Specification for PB Exterior Insulation and Finish Systems |
E2570/E2570M-07(2014)E1: | Standard Test Methods for Evaluating Water-resistive Barrier (WRB) Coatings Used Under Exterior Insulation and Finish Systems (EIFS) or EIFS with Drainage |
E2634-11(2015): | Standard Specification for Flat Wall Insulating Concrete Form (ICF) Systems |
F844-07a(2013): | Standard Specification for Washers, Steel, Plain (Flat), Unhardened for General Use |
F876-15A: | Specification for Cross-linked Polyethylene (PEX) Tubing |
F877-2011A: | Specification for Cross-linked Polyethylene (PEX) Plastic Hot- and Cold-water Distribution Systems |
F1055-13: | Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene and Crosslinked Polyethylene Pipe and Tubing |
F1281-11: | Specification for Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX) Pressure Pipe |
F1282-10: | Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe |
F1554-15: | Specification for Anchor Bolts, Steel, 36, 55 and 105-ksi Yield Strength |
F1667-15: | Specification for Driven Fasteners, Nails, Spikes and Staples |
F1807-15: | Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing |
F1924-12: | Standard Specification for Plastic Mechanical Fittings for Use on Outside Diameter Controlled Polyethylene Gas Distribution Pipe and Tubing |
F1960-15: | Specification for Cold Expansion Fittings with PEX Reinforcing Rings for Use with Crosslinked Polyethylene (PEX) Tubing |
F1970-12E1: | Standard Specification for Special Engineered Fittings, Appurtenances or Valves for Use in Poly (Vinyl Chloride) (PVC) or Chlorinated Poly (Vinyl Chloride) (CPVC) Systems |
F1973-13E1: | Standard Specification for Factory Assembled Anodeless Risers and Transition Fittings in Polyethylene (PE) and Polyamide 11 (PA 11) Fuel Gas Distribution Systems |
F 2090-17: | Specification for Window Fall Prevention Devices with Emergency Escape (Egress) Release Mechanisms |
F2098-08: | Standard Specification for Stainless Steel Clamps for Securing SDR9 Cross-linked Polyethylene (PEX) Tubing to Metal Insert and Plastic Insert Fittings |
F2389-15: | Standard for Pressure-rated Polypropylene (PP) Piping Systems |
F2623-14: | Standard Specification for Polyethylene of Raised Temperature (PE-RT) SDRG Tubing |
F2735-09: | Standard Specification for Plastic Insert Fittings for SDR9 Cross-linked Polyethylene (PEX) and Polyethylene of Raised Temperature (PE-RT) Tubing |
F2769-14: | Polyethylene or Raised Temperature (PE-RT) Plastic Hot and Cold-Water Tubing and Distribution Systems |
F2806-10(2015): | Standard Specification for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe (Metric SDR-PR) |
F2945-2015: | Standard Specification for Polyamide 11 Gas Pressure Pipe, Tubing and Fittings |
F2969-12: | Standard Specification for Acrylonitrile-butadiene-styrene (ABS) IPS Dimensioned Pressure Pipe |
AWC | American Wood Council 222 Catoctin Circle SE, Suite 201 Leesburg, VA 20175 |
Standard referenced | Title |
AWC STJR-2015: | Span Tables for Joists and Rafters |
ANSI/AWC WFCM-2018: | Wood Frame Construction Manual for One- and Two-family Dwellings |
ANSI/AWC NDS-2018: | National Design Specification (NDS) for Wood Construction-with 2018 Supplement |
ANSI/AWC PWF-2015: | Permanent Wood Foundation Design Specification |
AWPA | American Wood Protection Association P.O. Box 361784 Birmingham, AL 35236-1784 |
Standard referenced | Title |
C1-03: | All Timber Products-Preservative Treatment by Pressure Processes |
M4-16: | Standard for the Care of Preservative-treated Wood Products |
U1-16: | USE CATEGORY SYSTEM: User Specification for Treated Wood Except Commodity Specification H |
AWS | American Welding Society 8669 NW 36 Street, #130 Miami, FL 33166 |
Standard referenced | Title |
ANSI/AWS A5.31M/A5.31-2012: | Specification for Fluxes for Brazing and Braze Welding Edition: 2nd |
AWWA | American Water Works Association 6666 West Quincy Avenue Denver, CO 80235 |
Standard referenced | Title |
C903-16: | Polyethylene-aluminum-polyethylene (PE-AL-PE) Composite Pressure Pipe, 12 mm (1/2 in.) through 50 mm (2 in.), for Water Service |
CEN | European Committee for Standardization (EN) Central Secretariat Rue de Stassart 36 B-10 50 Brussels |
Standard referenced | Title |
EN 15250-2007: | Slow Heat Release Appliances Fired by Solid Fuel Requirements and Test Methods |
CPA | Composite Panel Association 19465 Deerfield Avenue, Suite 306 Leesburg, VA 20176 |
Standard referenced | Title |
ANSI A135.4-2012: | Basic Hardboard |
ANSI A135.5-2012: | Prefinished Hardboard Paneling |
ANSI A135.6-2012: | Engineered Wood Siding |
ANSI A135.7-2012: | Engineered Wood Trim |
A208.1-2016: | Particleboard |
CPSC | Consumer Product Safety Commission 4330 East-West Highway Bethesda, MD 20814 |
Standard referenced | Title |
16 CFR, Part 1201 -(2002): | Safety Standard for Architectural Glazing |
16 CFR, Part 1209 -(2002): | Interim Safety Standard for Cellulose Insulation |
16 CFR, Part 1404 -(2002): | Cellulose Insulation |
CSA | CSA Group 8501 East Pleasant Valley Road Cleveland, OH 44131-5516 |
Standard referenced | Title |
AAMA/WDMA/CSA | North American Fenestration Standard/ |
101/I.S.2/A440-17: | Specification for Windows, Doors and Unit Skylights |
ANSI/CSA FC I-2014: | Fuel Cell Technologies-Part 3-100; Stationary fuel cell power systems-Safety |
ASME A17.1/ CSA B44-2016: | Safety Code for Elevators and Escalators |
CSA 8-93: | Requirements for Gas Fired Log Lighters for Wood Burning Fireplaces |
B44-2016: | Safety Code for Elevators and Escalators |
B55.1-2015: | Test Method for Measuring Efficiency and Pressure Loss of Drain Water Heat Recovery Units |
B55.2-2015: | Drain Water Heat Recovery Units |
B137.9-16: | Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe Systems |
B137.10-13: | Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PE-AL-PE) Composite Pressure Pipe Systems |
B137.18-13: | Polyethylene of Raised Temperature (PE-RT) Tubing Systems for Pressure Applications |
C22.2 No. 218.1- M89(R2011): | Spas, Hot Tubs and Associated Equipment |
C22.2 No. 236-15: | Heating and Cooling Equipment |
CSA C448 Series-16: | Design and Installation of Earth Energy Systems |
CSA O325-07: | Construction Sheathing |
O437-Series-93: | Standards on OSB and Waferboard (Reaffirmed 2006) |
CSA C22.2 No. 60335-2-40-2022: | Household and Similar Electrical Appliances -Safety- Part 2-40: Particular Requirements for Electrical Heat Pumps, AirConditioners and Dehumidifiers |
CSSB | Cedar Shake & Shingle Bureau P.O. Box 1178 Sumas, WA 98295-1178 |
Standard referenced | Title |
CSSB-97: | Grading and Packing Rules for Western Red Cedar Shakes and Western Red Shingles of the Cedar Shake and Shingle Bureau |
DASMA | Door & Access Systems Manufacturers Association International 1300 Sumner Avenue Cleveland, OH 44115-2851 |
Standard referenced | Title |
105-2016: | Test Method for Thermal Transmittance and Air Infiltration of Garage Doors and Rolling Doors |
108-2017: | Standard Method for Testing Garage Doors, Rolling Doors and Flexible Doors; Determination of Structural Performance Under Uniform Static Air Pressure Difference |
115-2016: | Standard Method for Testing Sectional Garage Doors, Rolling Doors and Flexible Doors: Determination of Structural Performance Under Missile Impact and Cyclic Wind Pressure |
DOC | United States Department of Commerce 1401 Constitution Avenue, NW Washington, DC 20230 |
Standard referenced | Title |
PS 1-09: | Structural Plywood |
PS 2-10: | Performance Standard for Wood-based Structural-use Panels |
PS 20-05: | American Softwood Lumber Standard |
DOTn | U.S. Department of Transportation 1200 New Jersey Avenue SE East Building, 2nd floor Washington, DC 20590 |
Standard referenced | Title |
49 CFR, Parts 192.281(e) & 192.283 (b) (2009): | Transportation of Natural and Other Gas by Pipeline: Minimum Federal Safety Standards |
FEMA | Federal Emergency Management Agency 500 C Street SW Washington, DC 20472 |
Standard referenced | Title |
FEMA TB-2-08: | Flood Damage-resistant Materials Requirements |
FEMA TB-11-01: | Crawlspace Construction for Buildings Located in Special Flood Hazard Area |
FM | FM Approvals Headquarters Office 1151 Boston-Providence Turnpike P.O. Box 9102 Norwood, MA 02062 |
Standard referenced | Title |
4450-(1989): | Approval Standard for Class 1 Insulated Steel Deck Roofs-with Supplements through July 1992 |
4880-(2015): | Approval Standard for Class 1 Rating of Building Panels or Interior Finish Materials |
GA | Gypsum Association 6525 Belcrest Road, Suite 480 Hyattsville, MD 20782 |
Standard referenced | Title |
GA-253-2016: | Application of Gypsum Sheathing |
HPVA | Hardwood Plywood & Veneer Association 1825 Michael Faraday Drive Reston, Virginia 20190 |
Standard referenced | Title |
ANSI/HPVA HP-1-2016: | American National Standard for Hardwood and Decorative Plywood |
HVI | Home Ventilating Institute 1000 North Rand Road Suite 214 Wauconda, Il 60084 |
Standard referenced | Title |
916-09 | Airflow Test Procedure |
ICC | International Code Council, Inc. 500 New Jersey Avenue NW 6th Floor Washington, DC 20001 |
Standard referenced | Title |
ANSI/RESNET/ICC 301-2014: | Standard for the Calculation and Labeling of the Energy Performance of Low-Rise Residential Buildings using the Energy Rating Index, March 7, 2014, republished 2016 |
ANSI/RESNET/ICC 380-2016: | Standard for Testing Airtightness of Building Enclosures, Airtightness of Heating and Cooling Air Distribution and Airflow of Mechanical Ventilation Systems |
ICC/ANSI A117.1-09: | Accessible and Usable Buildings and Facilities |
ICC 400-17: | Standard on the Design and Construction of Log Structures |
ICC 500-14: | ICC/NSSA Standard on the Design and Construction of Storm Shelters |
ICC 600-14: | Standard for Residential Construction in High-wind Regions |
ICC 900/SRCC 300-2015: | Solar Thermal System Standard |
ICC 901/SRCC 100-2015: | Solar Thermal Collector Standard |
IEBC-18: | International Existing Building Code® |
IECC-18: | International Energy Conservation Code® |
IECC-06: | International Energy Conservation Code® for use with 1101.6 only. |
IFGC-18: | International Fuel Gas Code® |
IEEE | Institute of Electrical and Electronic Engineers, Inc. 3 Park Avenue, 17th Floor New York, NY 10016-5997 |
Standard referenced | Title |
515.1-2012: | IEEE Standard for the Testing, Design, Installation and Maintenance of Electrical Resistance Trace Heating for Commercial Applications |
ISO | International Organization for Standardization Chemin de Blandonnet 8 CP 401 1214 Vernier Geneva, Switzerland |
Standard referenced | Title |
8336-2009: | Fibre-cement Flat Sheets-product Specification and Test Methods |
15874-2002: | Polypropylene Plastic Piping Systems for Hot and Cold Water Installations |
MSS | Manufacturers Standardization Society of the Valve and Fittings Industry 127 Park Street, NE Vienna, VA 22180 |
Standard referenced | Title |
SP-58-09: | Pipe Hangers and Supports-Materials, Design, Manufacture, Selection, Application and Installation |
NAIMA | North American Insulation Manufacturers Association 11 Canal Center Plaza, Suite 101 Alexandria VA 22314 |
Standard referenced | Title |
AH 116-09: | Fibrous Glass Duct Construction Standards, Fifth Edition |
NFPA | National Fire Protection Association 1 Batterymarch Park Quincy, MA 02169-7471 |
Standard referenced | Title |
13-16: | Standard for Installation of Sprinkler Systems |
13D-16: | Standard for the Installation of Sprinkler Systems in One- and Two-family Dwellings and Manufactured Homes |
13R-16: | Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies |
30-15 | Flammable and combustible liquids code |
31-16: | Standard for the Installation of Oil-burning Equipment |
37-10 | Standard for the installation and use of stationary combustion engines and gas turbines |
58-17: | Liquefied Petroleum Gas Code |
70-23: | National Electrical Code (as modified in Chapter 34) |
72-16: | National Fire Alarm and Signaling Code |
85-15: | Boiler and Combustion Systems Hazards Code |
110-10 | Standard for emergency and standby power systems |
111-10 | Standard on stored electrical energy emergency and standby power systems |
211-16: | Standard for Chimneys, Fireplaces, Vents and Solid Fuel Burning Appliances |
259-18: | Standard for Test Method for Potential Heat of Building Materials |
275-17: | Standard Method of Fire Tests for the Evaluation of Thermal Barriers |
286-15: | Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth |
501-17: | Standard on Manufactured Housing |
720-15: | Standard for the Installation of Carbon Monoxide (CO) Detectors and Warning Equipment |
853-15: | Standard on the Installation of Stationary Fuel Cell Power Systems |
NFRC | National Fenestration Rating Council, Inc. 6305 Ivy Lane, Suite 140 Greenbelt, MD 20770 |
Standard referenced | Title |
100-2017: | Procedure for Determining Fenestration Products U-Factors |
200-2017: | Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence |
400-2017: | Procedure for Determining Fenestration Product Air Leakage |
NSF | NSF International 789 N. Dixboro Road P.O. Box 130140 Ann Arbor, MI 48105 |
Standard referenced | Title |
14-2015: | Plastics Piping System Components and Related Materials |
358-1-2014: | Polyethylene Pipe and Fittings for Water-based Ground Source "Geothermal" Heat Pump Systems |
358-2-2012: | Polypropylene Pipe and Fittings for Water-based Ground Source "Geothermal" Heat Pump Systems |
PCA | Portland Cement Association 5420 Old Orchard Road Skokie, IL 60077 |
Standard referenced | Title |
100-12: | Prescriptive Design of Exterior Concrete Walls for One- and Two-family Dwellings (Pub. No. EB241) |
SBCA | Structural Building Components Association 6300 Enterprise Lane Madison, WI 53719 |
Standard referenced | Title |
BCSI-2013 (Updated March 2015): | Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses |
CFS-BCSI-2008: | Cold-formed Steel Building Component Safety Information (CFSBCSI) Guide to Good Practice for Handling, Installing & Bracing of Cold-formed Steel Trusses |
FS100-12: | Standard Requirements for Wind Pressure Resistance of Foam Plastic Insulating Sheathing Used in Exterior Wall Covering Assemblies |
SMACNA | Sheet Metal & Air Conditioning Contractors National Assoc. Inc 4021 Lafayette Center Road Chantilly, VA 22021 |
Standard referenced | Title |
SMACNA-10: | Fibrous Glass Duct Construction Standards (2003) |
SMACNA/ANSI-2016: | HVAC Duct Construction Standards- Metal and Flexible 4th Edition (ANSI) 2016 |
TMS | The Masonry Society 105 South Sunset Street, Suite Q Longmont, CO 80501 |
Standard referenced | Title |
402-2016: | Building Code Requirements for Masonry Structures |
403-2017: | Direct Design Handbook for Masonry Structures |
404-2016: | Standard for the Design of Architectural Cast Stone |
602-2016: | Specification for Masonry Structures |
TPI | Truss Plate Institute 218 N. Lee Street, Suite 312 Alexandria, VA 22314 |
Standard referenced | Title |
TPI 1-2014: | National Design Standard for Metal-plate-connected Wood Truss Construction |
UL | UL LLC 333 Pfingsten Road Northbrook, IL 60062 |
Standard referenced | Title |
17-2008: | Vent or Chimney Connector Dampers for Oil-fired Appliances-with revisions through September 2013 |
55A-04: | Materials for Built-up Roof Coverings |
58-96: | Steel Underground Tanks for Flammable and Combustible Liquids-with Revisions through July 1998 |
80-2007: | Steel Tanks for Oil-burner Fuel- with revisions through January 2014 |
103-2010: | Factory-built Chimneys for Residential Type and Building Heating Appliances- with revisions through July 2012 |
127-2011: | Factory-built Fireplaces- with revisions through May 2015 |
174-04: | Household Electric Storage Tank Water Heaters- with revisions through April 2015 |
180-2012: | Liquid-level Indicating Gauges for Oil Burner Fuels and Other Combustible Liquids |
181-05: | Factory-made Air Ducts and Air Connectors-with revisions through May 2003 |
181A-2013: | Closure Systems for Use with Rigid Air Ducts and Air Connectors- with revisions through December 1998 |
181B-2013: | Closure Systems for Use with Flexible Air Ducts and Air Connectors- with revisions through August 2003 |
217-06: | Single- and Multiple-station Smoke Alarms- with revisions through October 2015 |
263-2011: | Standards for Fire Test of Building Construction and Materials-with revisions through June 2015 |
268-2009: | Smoke Detectors for Fire Alarm Systems |
325-02: | Door, Drapery, Gate, Louver and Window Operations and Systems-with revisions through May 2015 |
343-2008: | Pumps for Oil-burning Appliances- with revisions through June 2013 |
378-06: | Draft Equipment- with revisions through June 12, 2014 |
441-10: | Gas Vents-with revisions through June 12, 2014 |
507-99: | Standard for Electric Fans |
508-99: | Industrial Control Equipment- with revisions through October 2013 |
515-11: | Electrical Resistance Heat Tracing for Commercial and Industrial Applications Including Revisions through July 2015 |
536-97: | Flexible Metallic Hose- with revisions through December 2014 |
641-2010: | Type L, Low-temperature Venting Systems- with revisions through June 2013 |
651-2011: | Schedule 40 and Schedule 80 Rigid PVC Conduit and Fittings-with revisions through May 2014 |
705-04: | Standard for Power Ventilators- with revisions through December 2013 |
723-08: | Standard for Test for Surface Burning Characteristics of Building Materials- with revisions through August 2013 |
726-95: | Oil-fired Boiler Assemblies- with revisions through October 2013 |
727-06: | Oil-fired Central Furnaces- with revisions through October 2013 |
729-03: | Oil-fired Floor Furnaces- with revisions through October 2013 |
730-03: | Oil-fired Wall Furnaces- with revisions through October 2013 |
732-95: | Oil-fired Storage Tank Water Heaters- with revisions through October 2013 |
737-2011: | Fireplaces Stoves- with revisions through August 2015 |
790-04: | Standard Test Methods for Fire Tests of Roof Coverings-with revisions through July 2014 |
795-2011: | Commercial-industrial Gas Heating Equipment- with revisions through November 2013 |
834-04: | Heating, Water Supply and Power Boilers- Electric-with revisions through December 2013 |
842-07: | Valves for Flammable Fluids- with revisions through May 2015 |
858-05: | Household Electric Ranges- with revisions through June 2015 |
875-09: | Electric Dry-bath Heaters- with revisions through December 2013 |
896-93: | Oil-burning Stoves- with revisions through November 2013 |
923-2013: | Microwave Cooking Appliances- with revisions through June 2015 |
959-2010: | Medium Heat Appliance Factory-built Chimneys- with revisions through June 2014 |
1026-2012: | Electric Household Cooking and Food Serving Appliances-with revisions through August 2015 |
1040-96: | Fire Test of Insulated Wall Construction- with revisions through October 2012 |
1042-2009: | Electric Baseboard Heating Equipment- with revisions through September 2014 |
1256-02: | Fire Test of Roof Deck Construction- with revisions through July 2013 |
1261-01: | Electric Water Heaters for Pools and Tubs- with revisions through July 2012 |
1479-03: | Fire Tests of Through-Penetration Firestops- with revisions through June 2015 |
1482-2011: | Solid-Fuel-type Room Heaters- with revisions through August 2015 |
1563-2009: | Standard for Electric Spas, Hot Tubs and Associated Equipment-with revisions through March 2015 |
1618-09: | Wall Protectors, Floor Protectors, and Hearth Extensions-with revisions through October 2015 |
1693-2010: | Electric Radiant Heating Panels and Heating Panel Sets-with revisions through October 2011 |
1703-02: | Flat-plate Photovoltaic Modules and Panels- with revisions through October 2015 |
1715-97: | Fire Test of Interior Finish Material- with revisions through January 2013 |
1738-2010: | Venting Systems for Gas-burning Appliances, Categories II, III and IV- with revisions through November 2014 |
1741-2010: | Inverters, Converters, Controllers and Interconnection System Equipment with Distributed Energy Resources- with revisions through January 2015 |
1777-07: | Chimney Liners- with revisions through October 2015 |
1897-12: | Uplift Tests for Roof Covering Systems- with revisions through September 2015 |
1995-2015: | Heating and Cooling Equipment- |
1996-2009: | Electric Duct Heaters- with revisions through June 2014 |
2034-08: | Standard for Single- and Multiple-station Carbon Monoxide Alarms-with revisions through March 2015 |
2075-2013: | Standard for Gas and Vapor Detectors and Sensors |
2158A-2010: | Outline of Investigation for Clothes Dryer Transition Duct |
2200-15 | Stationary engine generator assemblies |
2523-09: | Standard for Solid Fuel-fired Hydronic Heating Appliances, Water Heaters and Boilers- with revisions through February 2013 |
2703-14: | Mounting Systems, Mounting Devices, Clamping/Retention Devices and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels |
9540-14: | Outline of Investigation for Energy Storage Systems and Equipment |
60335-2-40-2022: | Household and Similar Electrical Appliances -Safety- Part 2-40: |
Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers |
ULC | ULC 13775 Commerce Parkway Richmond, BC V6V 2V4 |
Standard referenced | Title |
CAN/ULC S 102.2-2010: | Standard Methods for Test for Surface Burning Characteristics of Building Materials and Assemblies |
US-FTC | United States-Federal Trade Commission 600 Pennsylvania Avenue NW Washington, DC 20580 |
Standard referenced | Title |
CFR Title 16(2015): | R-value Rule |
WDMA | Window and Door Manufacturers Association 2025 M Street NW, Suite 800 Washington, DC 20036-3309 |
Standard referenced | Title |
AAMA/WDMA/CSA 101/ I.S2/A440-17: | North American Fenestration Standard/ Specifications for Windows, Doors and Skylights |
I.S. 11-13: | Industry Standard Analytical Method for Design Pressure (DP) Ratings of Fenestration Products |
WMA | World Millwork Alliance (formerly Association of Millwork Distributors Standards AMD) 10047 Robert Trent Parkway New Port Richey, FL 34655-4649 |
Standard referenced | Title |
ANSI WMA 100-2016: | Standard Method of Determining Structural Performance Ratings of Side Hinged Exterior Door Systems and Procedures for Component Substitution |
Ohio Admin. Code 4101:8-44-01
Five Year Review (FYR) Dates: 7/1/2024
Promulgated Under: 119.03
Statutory Authority: 3781.10(A)(1)
Rule Amplifies: 3781.01, 3781.06, 3781.10, 3781.11, 3791.04, 4740.14
Prior Effective Dates: 05/27/2006, 01/01/2008, 03/31/2008 (Emer.), 06/24/2008, 01/01/2009, 01/01/2013, 07/01/2014, 01/01/2016, 01/01/2018, 07/01/2019