Ohio Admin. Code 4101:3-8-01

Current through all regulations passed and filed through December 2, 2024
Section 4101:3-8-01 - Indirect/special waste

Chapter 8 of the International Plumbing Code, 2021 edition, as incorporated by reference and modified in Section 101.1.1 of this code, is further modified as follows:

(A)Modify section 802.1 as follows:

Change the reference from "802.1.7" to "802.1.8" and add an exception that reads:

Exception:Approved health care related fixtures, devices, and equipment may be directly connected to the drainage system if required to be directly connected in accordance with the manufacturer's installation instructions.

(B)Add new section 802.1.8 to read as follows:
802.1.8Dental, drinking or soda fountain, bar sink, floor or shower drain waste. Wastes from dental or cuspidor fountains, drinking fountains, soda fountains, bar sinks, floor drains or shower drains may be indirectly connected by means of an air break to the sanitary drainage system . Each indirectly connected item listed above is to discharge, individually, to a directly connected floor drain, waste receptor or standpipe.
(C)Modify section 802.4 as follows:

Add an exception that reads: Exception: Standpipes only require access.

Replaces: 4101:3-3-01, 4101:3-8-01

Ohio Admin. Code 4101:3-8-01

Effective: 3/1/2024
Five Year Review (FYR) Dates: 03/01/2029
Promulgated Under: 119.03
Statutory Authority: 3781.10(A)(1), 4104.43 (A)(1)
Rule Amplifies: 3781.10, 3781.11, 3791.04
Prior Effective Dates: 04/15/1974, 07/01/1978, 12/01/1985, 07/05/1993, 02/01/1996, 01/01/1997, 03/01/1998, 07/01/1998, 01/01/2002, 08/15/2003, 01/01/2004, 03/01/2005, 09/06/2005, 07/01/2007, 11/01/2011, 07/01/2014, 01/01/2016, 10/10/2016, 11/01/2017