Ohio Admin. Code 4101:3-5-01

Current through all regulations passed and filed through December 2, 2024
Section 4101:3-5-01 - Water heaters

Chapter 5 of the International Plumbing Code, 2021 edition, as incorporated by reference and modified in Section 101.1.1 of this code, is further modified as follows:

(A)Modify section 501.1 to add an exception to read as follows:

Exception: Water heaters are to comply with the "Ohio Boiler and Pressure Vessels rules," Chapters 4101:4-1 to 4101:4-10 of the Administrative Code, when any of the following limitations are exceeded:

1. Heat input of two hundred thousand BTU per hour;
2. Water temperature of two hundred ten degrees Fahrenheit;
3. Nominal water containing capacity of one hundred twenty gallons.
(B)Modify section 501.5 as follows:

Replace the term "third-party certified" with the phrase "listed by an approved agency as complying with the applicable referenced standards."

Replaces: 4101:3-5-01

Ohio Admin. Code 4101:3-5-01

Effective: 3/1/2024
Five Year Review (FYR) Dates: 03/01/2029
Promulgated Under: 119.03
Statutory Authority: 3781.10(A)(1), 4104.02 (A)(1)
Rule Amplifies: 3781.10, 3781.11, 3791.04
Prior Effective Dates: 03/01/1998, 10/01/1999, 07/15/2000, 01/01/2002, 01/01/2004, 07/01/2007, 11/01/2011, 11/01/2017