Ohio Admin. Code 3745-51-764

Current through all regulations passed and filed through December 2, 2024
Section 3745-51-764 - Recordkeeping requirements - equipment leaks
(A)
(1) Each remanufacturer or other person who stores or treats the hazardous secondary material subject to rules 3745-51-750 to 3745-51-764 of the Administrative Code shall comply with the recordkeeping requirements of this rule.
(2) A remanufacturer or other person who stores or treats the hazardous secondary material in more than one hazardous secondary material management unit subject to rules 3745-51-750 to 3745-51-764 of the Administrative Code may comply with the recordkeeping requirements for these hazardous secondary material management units in one recordkeeping system if the system identifies each record by each hazardous secondary material management unit.
(B) Remanufacturer's and other persons who store or treat the hazardous secondary material shall record and keep the following information at the facility:
(1) For each piece of equipment to which rules 3745-51-750 to 3745-51-764 of the Administrative Code applies.
(a) Equipment identification number and hazardous secondary material management unit identification.
(b) Approximate locations within the facility (e.g., identify the hazardous secondary material management unit on a facility plot plan).
(c) Type of equipment (e.g., a pump or pipeline valve).
(d) Per cent by weight total organics in the hazardous secondary material stream at the equipment.
(e) Hazardous secondary material state at the equipment (e.g., gas or vapor or liquid).
(f) Method of compliance with the standard (e.g., "monthly leak detection and repair" or "equipped with dual mechanical seals").
(2) For facilities that comply with paragraph (A)(2) of rule 3745-51-733 of the Administrative Code, an implementation schedule as specified in paragraph (A)(2) of rule 3745-51-733 of the Administrative Code.
(3) Where a remanufacturer or other person who stores or treats the hazardous secondary material chooses to use test data to demonstrate the organic removal efficiency or total organic compound concentration achieved by the control device, a performance test plan as specified in paragraph (B)(3) of rule 3745-51-735 of the Administrative Code.
(4) Documentation of compliance with rule 3745-51-760 of the Administrative Code, including the detailed design documentation or performance test results specified in paragraph (B)(4) of rule 3745-51-735 of the Administrative Code.
(C) When each leak is detected as specified in rules 3745-51-752, 3745-51-753, 3745-51-757, and 3745-51-758 of the Administrative Code, the following requirements apply:
(1) A weatherproof and readily visible identification, marked with the equipment identification number, the date evidence of a potential leak was found in accordance with paragraph (A) of rule 3745-51-758 of the Administrative Code, and the date the leak was detected, shall be attached to the leaking equipment.
(2) The identification on equipment, except on a valve, may be removed after the equipment has been repaired.
(3) The identification on a valve may be removed after the equipment has been monitored for two successive months as specified in paragraph (C) of rule 3745-51-757 of the Administrative Code and no leak has been detected during those two months.
(D) When each leak is detected as specified in rules 3745-51-752, 3745-51-753, 3745-51-757, and 3745-51-758 of the Administrative Code, the following information shall be recorded in an inspection log and shall be kept at the facility:
(1) The instrument and operator identification numbers and the equipment identification number.
(2) The date evidence of a potential leak was found in accordance with paragraph (A) of rule 3745-51-758 of the Administrative Code.
(3) The date the leak was detected and the dates of each attempt to repair the leak.
(4) Repair methods applied in each attempt to repair the leak.
(5) "Above ten thousand" if the maximum instrument reading measured by the methods specified in paragraph (B) of rule 3745-51-763 of the Administrative Code after each repair attempt is equal to or greater than ten thousand parts per million (ppm).
(6) "Repair delayed" and the reason for the delay if a leak is not repaired within fifteen calendar days after discovery of the leak.
(7) Documentation supporting the delay of repair of a valve in compliance with paragraph (C) of rule 3745-51-759 of the Administrative Code.
(8) The signature of the remanufacturer or other person who stores or treats the hazardous secondary material (or designate) whose decision it was that repair could not be completed without a hazardous secondary material management unit shutdown.
(9) The expected date of successful repair of the leak if a leak is not repaired within fifteen calendar days.
(10) The date of successful repair of the leak.
(E) Design documentation and monitoring, operating, and inspection information for each closed-vent system and control device required to comply with rule 3745-51-760 of the Administrative Code shall be recorded and kept up to date at the facility as specified in paragraph (C) of rule 3745-51-735 of the Administrative Code. Design documentation is specified in paragraphs (C)(1) and (C)(2) of rule 3745-51-735 of the Administrative Code and monitoring, operating, and inspection information in paragraphs (C)(3) to (C)(8) of rule 3745-51-735 of the Administrative Code.
(F) For a control device other than a thermal vapor incinerator, catalytic vapor incinerator, flare, boiler, process heater, condenser, or carbon adsorption system, the director will specify the appropriate recordkeeping requirements.
(G) The following information pertaining to all equipment subject to the requirements in rules 3745-51-752 to 3745-51-760 of the Administrative Code shall be recorded in a log that is kept at the facility:
(1) A list of identification numbers for equipment (except welded fittings) subject to the requirements of rules 3745-51-750 to 3745-51-764 of the Administrative Code.
(2)
(a) A list of identification numbers for equipment that the remanufacturer or other person who stores or treats the hazardous secondary material elects to designate for no detectable emissions, as indicated by an instrument reading of less than five hundred ppm above background, under paragraph (E) of rule 3745-51-752, paragraph (I) of rule 3745-51-753, and paragraph (F) of rule 3745-51-757 of the Administrative Code.
(b) The designation of this equipment as subject to the requirements of paragraph (E) of rule 3745-51-752, paragraph (I) of rule 3745-51-753, and paragraph (F) of rule 3745-51-757 of the Administrative Code shall be signed by the remanufacturer or other person who stores or treats the hazardous secondary material.
(3) A list of equipment identification numbers for pressure relief devices required to comply with paragraph (A) of rule 3745-51-754 of the Administrative Code.
(4)
(a) The dates of each compliance test required in paragraph (E) of rule 3745-51-752, paragraph (I) of rule 3745-51-753, rule 3745-51-754, and paragraph (F) of rule 3745-51-757 of the Administrative Code.
(b) The background level measured during each compliance test.
(c) The maximum instrument reading measured at the equipment during each compliance test.
(5) A list of identification numbers for equipment in vacuum service.
(6) Identification, either by list or location (area or group) of equipment that contains or contacts hazardous secondary material with an organic concentration of at least ten per cent by weight for less than three hundred hours per calendar year.
(H) The following information pertaining to all valves subject to the requirements of paragraphs (G) and (H) of rule 3745-51-757 of the Administrative Code shall be recorded in a log that is kept at the facility:
(1) A list of identification numbers for valves that are designated as unsafe to monitor, an explanation for each valve stating why the valve is unsafe to monitor, and the plan for monitoring each valve.
(2) A list of identification numbers for valves that are designated as difficult to monitor, an explanation for each valve stating why the valve is difficult to monitor, and the planned schedule for monitoring each valve.
(I) The following information shall be recorded in a log that is kept at the facility for valves complying with rule 3745-51-762 of the Administrative Code:
(1) A schedule of monitoring.
(2) The per cent of valves found leaking during each monitoring period.
(J) The following information shall be recorded in a log that is kept at in the facility:
(1) Criteria required in paragraph (D)(5)(b) of rule 3745-51-752 and paragraph (E)(2) of rule 3745-51-753 of the Administrative Code and an explanation of the design criteria.
(2) Any changes to these criteria and the reasons for the changes.
(K) The following information shall be recorded in a log that is kept at the facility for use in determining exemptions as provided in rule 3745-51-750 of the Administrative Code and other specific rules:
(1) An analysis determining the design capacity of the hazardous secondary material management unit.
(2) A statement listing the hazardous secondary material influent to and effluent from each hazardous secondary material management unit subject to the requirements in rules 3745-51-752 to 3745-51-760 of the Administrative Code and an analysis determining whether these hazardous secondary materials are heavy liquids.
(3) An up to date analysis and the supporting information and data used to determine whether or not equipment is subject to the requirements in rules 3745-51-752 to 3745-51-760 of the Administrative Code. The record shall include supporting documentation as required by paragraph (D)(3) of rule 3745-51-763 of the Administrative Code when application of the knowledge of the nature of the hazardous secondary material stream or the process by which the hazardous secondary material stream was produced is used. If the remanufacturer or other person who stores or treats the hazardous secondary material takes any action (e.g., changing the process that produced the material) that could result in an increase in the total organic content of the material contained in or contacted by equipment determined not to be subject to the requirements in rules 3745-51-752 to 3745-51-760 of the Administrative Code, then a new determination is required.
(L) Records of the equipment leak information required by paragraph (D) of this rule and the operating information required by paragraph (E) of this rule need be kept only three years.
(M) The remanufacturer or other person who stores or treats the hazardous secondary material at a facility with equipment that is subject to rules 3745-51-750 to 3745-51-764 of the Administrative Code and to regulations at 40 CFR Part 60, Part 61, or Part 63 may elect to determine compliance with rules 3745-51-750 to 3745-51-764 of the Administrative Code either by documentation pursuant to rule 3745-51-764 of the Administrative Code, or by documentation of compliance with 40 CFR Part 60, Part 61, or Part 63 pursuant to the relevant provisions of 40 Part 60, Part 61, or Part 63. The documentation of compliance under 40 CFR Part 60, Part 61, or Part 63 shall be kept with or made readily available at the facility.

[Comment: For dates of non-regulatory government publications, publications of recognized organizations and associations, federal rules, and federal statutory provisions referenced in this rule, see rule 3745-50-11 of the Administrative Code titled "Incorporated by reference."]

Ohio Admin. Code 3745-51-764

Effective: 6/12/2023
Five Year Review (FYR) Dates: Exempt
Promulgated Under: 119.03
Statutory Authority: 3734.12
Rule Amplifies: 3734.12