Pc = Pm x 14 / (E - Y)
where:
Pc is the corrected concentration of the pollutant in the stack gas.
Pm is the measured concentration of the pollutant in the stack gas.
E is the oxygen concentration on a dry basis in the combustion air fed to the device.
Y is the measured oxygen concentration on a dry basis in the stack.
[Comment: For dates of non-regulatory government publications, publications of recognized organizations and associations, federal rules, and federal statutory provisions referenced in this rule, see rule 3745-50-11 of the Administrative Code titled "Incorporated by reference."]
Ohio Admin. Code 3745-266-105
Five Year Review (FYR) Dates: 6/7/2021 and Exempt
Promulgated Under: 119.03
Statutory Authority: 3734.12
Rule Amplifies: 3734.12
Prior Effective Dates: 12/07/2004, 10/31/2015