All pollutants or combinations of pollutants, for which aquatic life criteria have not been adopted in rule 3745-1-35 of the Administrative Code, may not exceed the water quality criteria or values derived using the procedures contained in this rule.
Where:
V = pooled acute slope, and A = ln (FAV at Z). Because V, A, and Z are known, the FAV can be calculated for any selected value of the water quality characteristic.
If fewer than three acceptable experimentally determined ACRs are available for the chemical, the secondary acute-chronic ratio (SACR) shall be determined using enough assumed ACRs of eighteen so that the total number of ACRs equals three. Calculate the SACR as the geometric mean of the three ACRs. If no experimentally determined ACRs are available, the SACR is eighteen.
Table 40-1.
Secondary acute factors
Number of minimum data requirements satisfied | Secondary acute factor |
1................................... | 21.9 |
2 and neither requirement includes the family Salmonidae........... | 13.0 |
2 and one requirement includes the family Salmonidae........... | 7.9 |
3................................... | 8.0 |
4................................... | 7.0 |
5................................... | 6.1 |
6................................... | 5.2 |
7................................... | 4.3 |
Ohio Admin. Code 3745-1-40
Five Year Review (FYR) Dates: 8/21/2023 and 03/06/2028