Section 3701:1-49-11 - Inspection, maintenance, and opening of a source or source holder
(A) Each licensee shall visually check source holders, logging tools, and source handling tools for defects before each use to ensure that the equipment is in good working condition and that required labeling is present. If defects are found, the equipment must be removed from service until repaired, and a record must be made listing: the date of check, name of inspector, equipment involved, defects found, and repairs made. These records must be retained for three years after the defect is found.
(B) Each licensee shall have a program for visual inspection and routine maintenance, at intervals not to exceed six months, of source holders, logging tools, injection tools, source handling tools, storage containers, transport containers, and uranium sinker bars to ensure that the required labeling is legible and that no physical damage is visible. If defects are found, the equipment must be removed from service until repaired, and a record must be made listing: date, equipment involved, inspection and maintenance operations performed, any defects found, and any actions taken to correct the defects. These records must be retained for three years after the defect is found.
(C) Removal of a sealed source from a source holder or logging tool, and maintenance on sealed sources or holders in which sealed sources are contained may not be performed by the licensee unless a written procedure developed pursuant to rule 3701:1-49-19 of the Administrative Code has been approved by the director, the United States nuclear regulatory commission or an agreement state.
(D) If a sealed source is stuck in the source holder, the licensee may not perform any operation, such as drilling, cutting, or chiseling, on the source holder unless the licensee is specifically approved by the director, the United States nuclear regulatory commission or an agreement state to perform this operation.
(E) The opening, repair, or modification of any sealed source must be performed by persons specifically approved to do so by the director, the United States nuclear regulatory commission or an agreement state.

Ohio Admin. Code 3701:1-49-11

Five Year Review (FYR) Dates: 5/24/2022 and 05/23/2027
Promulgated Under: 119.03
Statutory Authority: 3748.04
Rule Amplifies: 3748.04
Prior Effective Dates: 10/20/2002, 10/08/2007, 06/23/2017
Effective: 6/23/2017
Five Year Review (FYR) Dates: 03/27/2017 and 03/15/2022
Promulgated Under: 119.03
Statutory Authority: 3748.04
Rule Amplifies: 3748.04
Prior Effective Dates: 10/20/2002, 7/23/07