Remediation systems shall adhere to the following setbacks, unless greater setbacks are required to comply with minimum horizontal distance requirements set by the Division pursuant to 15A NCAC 02L .0107:
Feet | |
Any habitable residence or place of public assembly under separate ownership or not to be maintained as part of the project site | 100 |
Any well with the exception of a Division-approved groundwater monitoring well | 100 |
Surface waters (such as intermittent and perennial streams, perennial waterbodies, and wetlands) | 100 |
Surface water diversions (such as ephemeral streams, waterways, and ditches) | 25 |
Groundwater lowering ditches (where the bottom of the ditch intersects the seasonal high water table) | 25 |
Subsurface groundwater-lowering drainage systems | 25 |
Any building foundation except treatment facilities | 15 |
Any basement | 15 |
Any property line | 50 |
Any water line | 10 |
Any swimming pool | 100 |
Rock outcrops | 25 |
Public right-of-way | 50 |
15A N.C. Admin. Code 02T .1506
Eff. September 1, 2006;
Readopted Eff. January 1, 2018.
Eff. 9/1/2006.