CF = k(1.000-0.015r/r-s)
where:
CF = conversion factor (kg/metric ton per ppm, lb/short ton per ppm).
k = constant derived from material balance. For determining CF in metric units.
k = 0.0653. For determining CF in English units, k = 0.1306.
r = percentage of sulfur dioxide by volume entering the gas converter.
Appropriate corrections must be made for air injection plants, subject to the commissioner's approval.
s = percentage of sulfur dioxide by volume in the emissions to the atmosphere,
determined by the continuous monitoring system.
for nitrogen oxide continuous stack monitoring systems, the conversion factor will be established by measuring emissions with the continuous monitoring system concurrent with measuring emissions with the applicable reference method tests. Using only that portion of the continuous monitoring emission data that represents emission measurements concurrent with the reference method test periods, the conversion factor shall be determined by dividing the reference method test data averages by the monitoring data averages to obtain a ratio expressed in units of the applicable standard to units of the monitoring data, i.e., kg/metric ton per ppm (lb/short ton per ppm);
N.Y. Comp. Codes R. & Regs. Tit. 6 § 224.4