Current through Register Vol. 46, No. 45, November 2, 2024
Section 220-1.2 - Particulate emissions from existing kilns and clinker coolersExcept as provided in section 220-1.3 of this Subpart, no person shall cause or allow emission of particulates to the outdoor atmosphere from a portland cement kiln or clinker cooler in excess of the following emission rates:
(a) for process weight per hour less than or equal to 100,000 pounds, E = 0.024P0.665 where E is the emission rate in pounds per hour and P is the process weight per hour; or(b) for process weight per hour in excess of 100,000 pounds, 0.05 grains per standard cubic foot of gas on a dry basis.N.Y. Comp. Codes R. & Regs. Tit. 6 §§ 220-1.2