N.Y. Comp. Codes R. & Regs. tit. 12, Appendices, app A-10

Current through Register Vol. 46, No. 50, December 11, 2024
Appendix A-10

(cf. Part 38)

TABLE 1

EXEMPTIONS

Exemption 1. Except for persons who apply radioactive material to, or who incorporate radioactive material into, the following products, or persons who initially transfer them for sale or distribution, any person is exempt from the requirements of this Part (Rule) to the extent that he transfers, receives, possesses or uses the following products:

(i) timepieces or timepiece hands or dials containing radium which were manufactured prior to July 1, 1973;

(ii) timepieces or timepiece hands or dials containing radium which were manufactured under a specific license issued by the commissioner, the State Department of Health or any agreement state and which meet the following or equivalent conditions:

(ii) (a) timepieces or timepiece hands or dials containing not more than the following specified quantities of radium:

(ii) (1) 0.15 microcurie per watch;

(ii) (2) 0.03 microcurie per watch hand;

(ii) (3) 0.09 microcurie per watch dial;

(ii) (4) 0.20 microcurie per clock;

(ii) (5) 0.04 microcurie per clock hand;

(ii) (6) 0.12 microcurie per clock dial;

(ii) (b) the timepiece is not a pocket watch;

(ii) (c) the timepiece is marked or coded to identify the date of manufacture and that it contains radium;

(ii) (d) the timepiece emits sufficient light, omitting photoactivation, that its dial can be read in the dark during its entire lifetime;

(iii) timepieces or timepiece hands or dials containing not more than the following specified quantities of radioactive material and not exceeding the following specified levels of radiation:

(iii) (a) 25 millicuries of hydrogen 3 per timepiece;

(iii) (b) five millicuries of hydrogen 3 per hand;

(iii) (c) 15 millicuries of hydrogen 3 per dial (bezels when used shall be considered as part of the dial);

(iii) (d) 100 microcuries of promethium 147 per watch or 200 microcuries of promethium 147 per any other timepiece;

(iii) (e) 20 microcuries of promethium 147 per watch hand or 40 microcuries of promethium 147 per other timepiece hand;

(iii) (f) 60 microcuries of promethium 147 per watch dial or 120 microcuries of promethium 147 per other timepiece dial (bezels when used shall be considered as part of the dial);

(iii) (g) the levels of radiation from hands and dials containing promethium 147 will not exceed, when measured through 50 milligrams per square centimeter of absorber:

(iii) (1) for wrist watches. 0.1 millirad per hour at 10 centimeters from any surface;

(iii) (2) for pocket watches, 0.1 millirad per hour at one centimeter from any surface;

(iii) (3) for any other timepiece, 0.2 millirad per hour at 10 centimeters from any surface.

Exemption 2. Radioactive material contained in any item in a concentration not exceeding that set forth in Table 8. No person may introduce radioactive material into a product or material when such person knows or has reason to believe that such product or material will be transferred to persons who are exempt under this Exemption or equivalent regulations of the United States Nuclear Regulatory Commission or any agreement state, unless such introduction or transfer is accomplished in accordance with a specific license or permit issued pursuant to this Part (rule) or by the State Department of Health, the New York City Department of Health, the United States Nuclear Regulatory Commission or any agreement state, and such specific license or permit expressly authorizes such introduction. For the purposes of this Exemption, the processing of materials or items which results in an increase in the concentration of radioactive material therein shall be deemed to be the same as introduction by the addition of radioactive material.

Exemption 3. Source material contained in, but less than 0.05 percent by weight of, any chemical mixture, compound, solution or alloy.

Exemption 4. Source material contained in unrefined and unprocessed ore. This Exemption does not apply to any refinement or processing of ore containing 0.05 percent or more by weight of source material.

Exemption 5. Source material contained in any of the following products: glazed ceramic tableware, the glaze of which contains not more than 20 percent by weight of source material; glassware, containing not more than 10 percent by weight of source material, except glass brick, pane glass, ceramic tile and other glass, glass enamel or ceramic products used in building construction; glass enamel and glass enamel frit containing not more than 10 percent by weight of source material imported or ordered for importation in the United States, or initially distributed by manufacturers in the United States, before July 25, 1983; piezoelectric ceramic containing not more than two percent by weight of source material. This Exemption does not apply to the manufacture or importation of such products or their components.

Exemption 6. Thorium contained in incandescent gas mantles, vacuum tubes, welding rods, electric lamps for illuminating purposes provided that each lamp does not contain more than 50 milligrams of Thorium, or germicidal lamps and sunlamps and lamps for outdoor or industrial lighting provided that each lamp does not contain more than two grams of Thorium, or personnel neutron dosimeters provided that each dosimeter does not contain more than 50 milligrams of Thorium. This Exemption does not apply to the manufacture or importation of such products or their components.

Exemption 7. Uranium contained in counterweights installed in aircraft, rockets, projectiles or missiles, or stored or handled in connection with the installation or removal of such counterweights if such counterweights are manufactured or imported in accordance with a specific license issued by the United States Nuclear Regulatory Commission and such license provides that such counterweights may be distributed to persons who have not been issued a licensing document therefor, and if each such counterweight has been impressed with a statement, clearly legible after plating, which states "Depleted Uranium"(counterweights which were manufactured prior to December 1, 1969 are impressed with the statement "Caution-Radioactive Material-Uranium") and is durable and legibly labeled or marked with the identification of the manufacturer, and the statement "Unauthorized Alterations Prohibited."The Exemption contained herein shall not be deemed to authorize the chemical, physical or metallurgi cal treatment or processing of any such counterweights other than repair or restoration of any plating or other covering and there is no removal or penetration of the plating on such counterweights.

Exemption 8. Source material contained in photographic films, negatives or prints. This Exemption does not apply to the manufacture or importation of such products or their components.

Exemption 9. Tungsten-Thorium alloy or Magnesium-Thorium alloy containing not more than four percent by weight of Thorium when fabricated into any finished product or part thereof. This Exemption does not apply to the manufacture or importation of the product or to any treatment or processing thereof.

Exemption 10. [Reserved]

Exemption 11. Radiation equipment which by reason of its design cannot emit radiation at a level which, when measured five centimeters from the surface of such radiation equipment with all external shielding removed, exceeds a rate of 0.5 millirem in any hour. This Exemption does not apply to the testing or servicing of such equipment during the production thereof.

Exemption 12. Television receivers providing the dose rate averaged over 10 square centimeters at five centimeters from any outer surface is less than 0.5 millirem per hour. This Exemption does not apply to the testing or servicing of receivers during the production thereof.

Exemption 13. Radiation equipment during its storage, shipment, retail sale or other similar use in the course of which the equipment does not emit radiation. This Exemption does not apply to the labeling requirements of this Part (rule).

Exemption 14. Lock illuminators each containing not more than 15 millicuries of Hydrogen 3 or two millicuries of Promethium 147 installed in automobile locks, provided also that the radiation level from lock illuminators containing Promethium 147 does not exceed one millirad per hour at one centimeter from any surface when measured through 50 milligrams per square centimeter of absorber. This Exemption does not apply to the manufacture or Importation of such illuminators or to their installation into automobile locks.

Exemption 15. Rare earth metals and compounds, mixtures and products containing not more than 0.25 percent by weight Thorium, Uranium or any combination of these. This Exemption does not apply to the manufacture or importation of any of these products.

Exemption 16. Uranium used as shielding constituting part of any shipping container which is conspicuously and legibly impressed with the legend "CAUTION- RADIOACTIVE SHIELDING- URANIUM" and the Uranium metal is encased in mild steel or equally fire-resistant metal of minimum wall thickness of 3.2 millimeters. This Exemption does not authorize the manufacture or importation of any such shielding or container.

Exemption 17. Thorium contained in any finished optical lens which contains not more than 30 percent by weight Thorium. This Exemption does not apply to the importation or the shaping, grinding or polishing of such lenses, to manufacturing processes other than the assembly of such lenses into optical systems and devices without any alteration of the lens, or to the receipt, possession, use or transfer of Thorium contained in contact lenses or in spectacles, or in eyepieces in binoculars or other optical instruments.

Exemption 18. Uranium contained in any detector head for use in tire detection units. Each detector head shall contain not more than 0.01 microcurie of Uranium. This Exemption does not apply to the manufacture or importation of any detector head containing Uranium.

Exemption 19. Balances of precision, or balance parts, containing Tritium. Each such balance part shall contain not more than 0.5 millicurie of Tritium. This Exemption does not authorize the importation or the application of Tritium to or incorporation of Tritium in any such balances or balance parts.

Exemption 20. Marine compasses and other marine navigational instruments containing Tritium gas. Each such marine compass shall contain not more than 750 millicuries of Tritium gas. Other marine navigational instruments shall contain not more than 250 millicuries of Tritium gas. This Exemption does not authorize the importation, the application of Tritium to or the incorporation of Tritium in any such marine compasses or other marine navigational instruments.

Exemption 21. Thermostat dials and pointers containing not more than 25 millicuries of Tritium per thermostat. This Exemption does not authorize the importation, the application of Tritium to or the incorporation of Tritium in thermostat dials or pointers.

Exemption 22. Electron tubes containing specified amounts of radioactive material. Each tube contains no more than one of the following quantities of radioactive materials:

(i) 10 millicuries of Tritium, except for 150 millicuries of Tritium in microwave receiver protector tubes;

(ii) 1 microcurie of Cobalt 60;

(iii) 5 microcuries of Nickel 63;

(iv) 30 microcuries of Krypton 85;

(v) 5 microcuries of Cesium 137;

(vi) 30 microcuries of Promethium 147.

The radiation level due to the radioactive material contained in each electron tube shall not exceed one millirad per hour at one centimeter from any surface when measured through seven milligrams per square centimeter of absorber. This Exemption does not authorize the importation, application of radioactive material to, or incorporation of radioactive material into, any electron tube.

Exemption 23. Synthetic plastic resins containing Scandium 46 for sand consolidation in oil wells which have been manufactured in accordance with a specific license issued by the commissioner, the United States Nuclear Regulatory Commission or any agreement state, which authorizes distribution of such resins to persons exempt pursuant to this Part (rule) or equivalent regulations of the United States Nuclear Regulatory Commission or any agreement State or which have been imported pursuant to a specific license issued by the United States Nuclear Regulatory Commission authorizing distribution to persons exempt pursuant to this Part (rule) or equivalent regulations of the United States Nuclear Regulatory Commission or any agreement state. This Exemption does not authorize the manufacture or importation of any such resins.

Exemption 24. Automobile shift quadrants containing not more than 25 millicuries of Tritium. This Exemption does not authorize importation, the application of Tritium to, or the incorporation of Tritium in, any such automobile shift quadrant.

Exemption 25. Thorium contained in any finished aircraft engine part containing Nickel-Thoria alloy, provided that: the Thorium is dispersed in the Nickel-Thoria alloy in the form of finely divided Thoria (Thorium oxide); and the Thorium content of the Nickel-Thoria alloy does not exceed four percent by weight. This Exemption does not authorize the importation or manufacture of such finished aircraft engine parts containing Thorium.

Exemption 26. Radioactive material contained in instruments or devices other than timepieces covered by Exemption 1 to provide self-illumination. Any such instrument or device shall be produced, manufactured, processed, imported or transferred in accordance with a specific license issued by the United States Nuclear Regulatory Commission or an agreement state. Such a license shall authorize the transfer to persons exempt from the requirements of this Part (Rule) or equivalent regulations of the United States Nuclear Regulatory Commission or an agreement state, This Exemption does not apply to products used for frivolous purposes or in toys or adornments.

Exemption 27. Radioactive material contained in smoke, gas or aerosol detectors designed to protect life or property from fires or airborne hazards. Such detectors shall be produced, manufactured, processed, imported or transferred in accordance with specific licenses issued by an agreement state or by the United States Nuclear Regulatory Commission. Such licenses shall authorize the transfer of such detectors to persons exempt from the requirements of this Part (Rule) or equivalent regulations of the United States Nuclear Regulatory Commission or an agreement state.

Exemption 28. Radioactive material contained in individual, packaged quantities each of which does not exceed the value listed in Table 2 of this Part (rule). For purposes of this Exemption, an individual, packaged quantity may be composed of fractional parts of one or more of the exempt quantities, provided that the sum of such fractions shall not exceed unity. There shall be no commercial distribution or human use of radioactive material possessed under this Exemption. Also, sources obtained under this exemption shall not be used in a combination that exceeds the value listed in Table 2 of this Part for a single radionuclide, or the sum of the fractions for more than one radionuclide, as a source of ionizing radiation in any device designed for use in detecting, measuring, gauging or controlling thickness, density, level, interface location, radiation, leakage, or qualitative or quantitative chemical composition, or designed for producing light or an ionized atmosphere. Radioactive material exempted under this Part (rule) effective October 15, 1962, and which are larger in quantity than listed in Table 2 and obtained before September 1, 1971, shall continue to be exempt.

Exemption 29. Radioactive sources contained in or on ionizing radiation measuring instruments for purposes of internal calibration or standardization. No source shall exceed the quantity set forth in Table 2 of this Part (rule), or 0.05 microcurie of Americium-241, and each instrument shall contain no more than 10 such sources. For purposes of this Exemption, each source may contain more than one radionuclide. An individual exempt quantity may be composed of fractional parts of the exempt quantities in Table 2 of this Part, provided that the sum of the fractions shall not exceed unity. Such sources shall be produced, manufactured, processed, imported or transferred in accordance with a specific license issued by the United States Nuclear Regulatory Commission, an agreement state or a licensing nonagreement state. Such license shall authorize the transfer of such calibration sources to persons exempt from the requirements of this Part (rule) or equivalent regulations of the United States Nuclear Regulatory Commission or an agreement state.

Exemption 30. Cobalt-60 contained in spark gap irradiators for use in electrically ignited fuel oil burners having a firing rate of at least 11.4 liters (three gallons) per hour and each spark gap containing no more than one microcurie of Cobalt-60. Such spark gap irradiators shall be manufactured, assembled or imported in accordance with a specific license issued by the United States Nuclear Regulatory Commission or an agreement State. The exempt transfer of such spark gap irradiators shall be in accordance with a specific license issued by the United States Nuclear Regulatory Commission.

TABLE 2

EXEMPT QUANTITIES

Radionuclide

Exempt quantity (microcuries)

Antimony 122 (Sb 122) .......100
Antimony 124 (Sb 124) .......10
Antimony 125 (Sb 125) .......10
Arsenic 73 (As 73) .......100
Arsenic 74 (As 74) .......10
Arsenic 76 (As 76) .......10
Arsenic 77 (As 77) .......100
Barium 131 (Ba 131) .......10
Barium 133 (Ba 133) .......10
Barium 140 (Ba 140) .......10
Beryllium (Be 7) .......100
Bismuth 210 (Bi 210) .......1
Bromine 82 (Br 82) .......10
Cadmium 109 (Cd 109) .......10
Cadmium 115m (Cd 115m) .......10
Cadmium 115 (Cd 115) .......100
Calcium (Ca 45) .......10
Calcium 47 (Ca 47) .......10
Carbon 14 (C 14) .......100
Cerium 141 (Ce 141) .......100
Cerium 143 (Ce 143) .......100
Cerium 144 (Ce 144) .......1
Cesium 131 (Cs 131) .......1,000
Cesium 134m (Cs 134m) .......100
Cesium 134 (Cs 134) .......1
Cesium 135 (Cs 135) .......10
Cesium 136 (Cs 136) .......10
Cesium 137 (Cs 137) .......10
Chlorine 36 (Cl 36) .......10
Chlorine 38 (Cl 38) .......10
Chromium 51 (Cr 51) .......1,000
Cobalt 58m (Co 58m) .......10
Cobalt 58 (Co 58) .......10
Cobalt 60 (Co 60) .......1
Copper 64 (Cu 64) .......100
Dysprosium 165 (Dy 165) .......10
Dysprosium 166 (Dy 166) .......100
Erbium 169 (Er 169) .......100
Erbium 171 (Er 171) .......100
Europium 152 (Eu 152) 9.2h .......100
Europium 152 (Eu 152) 13 yr .......1
Europium 154 (Eu 154) .......1
Europium 155 (Eu 155) .......10
Fluorine 18 (F 18) .......1,000
Gadolinium 153 .......10
Gadolinium 159 (Gd 159) .......1,100
Gallium 72 (Ga 72) .......10
Germanium 71 (Ge 71) .......100
Gold 198 (Au 198) .......100
Gold 199 (Au 199) .......100
Hafnium 181 (Hf 181) .......10
Holmium 166 (Ho 166) .......100
Hydrogen 3 (H 3) .......1,000
Indium 113m (In 113m) .......100
Indium 114m (In 114m) .......10
Indium 114 (In 114) .......1
Indium 115m (In 115m) .......100
Indium 115 (In 115) .......10
Iodine 125 (I 125) .......1
Iodine 126 (I 126) .......1
Iodine 129 (I 129) .......0.1
Iodine 131 (I 131) .......1
Iodine 132 (I 132) .......10
Iodine 133 (I 133) .......1
Iodine 134 (I 134) .......10
Iodine 135 (I 135) .......10
Iridium 192 (Ir 192) .......10
Iridium 194 (Ir 194) .......100
Iron 55 (Fe 55) .......100
Iron 59 (Fe 59) .......10
Krypton 85 (Kr 85) .......100
Krypton 87 (Kr 87) .......10
Lanthanum 140 (La 140) .......10
Lutetium 177 (Lu 177) .......100
Manganese 52 (Mn 52) .......10
Manganese 54 (Mn 54) .......10
Manganese 56 (Mn 56) .......10
Mercury 197m (Hg 197m) .......100
Mercury 197 (Hg 197) .......100
Mercury 203 (Hg 203) .......10
Molybdenum 99 (Mo 99) .......100
Neodymium 147 (Nd 147) .......100
Neodymium 149 (Nd 149) .......100
Nickel 59 (Ni 59) .......100
Nickel 63 (Ni 63) .......10
Nickel 65 (Ni 65) .......100
Niobium 93m (Nb 93m) .......10
Niobium 95 (Nb 95) .......10
Niobium 97 (Nb 97) .......10
Osmium 185 (Os 185) .......10
Osmium l91m (Os l91m) .......100
Osmium 191 (Os 191) .......100
Osmium 193 (Os 193) .......100
Palladium 103 (Pd 103) .......100
Palladium 109 (Pd 109) .......100
Phosphorus 32 (P 32) .......10
Platinum 191 (Pt 191) .......100
Platinum 193m (Pt 193m) .......100
Platinum 193 (Pt 193) .......100
Platinum 197m (Pt 197m) .......100
Platinum 197 (Pt 197) .......100
Polonium 210 (Po 210) .......0.1
Potassium 42 (K 42) .......10
Praseodymium 142 (Pr 142) .......100
Praseodymium 143 (Pr 143) .......100
Promethium 147 (Pm 147) .......10
Promethium 149 (Pm 149) .......10
Radium 226 (Ra 226) .......0.1
Rhenium 186 (Re 186) .......100
Rhenium 188 (Re 188) .......100
Rhodium 103m (Rh 103m) .......100
Rhodium 105 (Rh 105) .......100
Rubidium 86 (Rb 86) .......10
Rubidium 87 (Rb 87) .......10
Ruthenium 97 (Ru 97) .......100
Ruthenium 103 (Ru 103) .......10
Ruthenium 105 (Ru 105) .......10
Ruthenium 106 (Ru 106) .......1
Samarium 151 (Sm 151) .......10
Samarium 153 (Sm 153) .......100
Scandium 46 (Sc 46) .......10
Scandium 47 (Sc 47) .......100
Scandium 48 (Sc 48) .......10
Selenium 75 (Se 75) .......10
Silicon 31 (Si 31) .......100
Silver 105 (Ag 105) .......10
Silver 110m (Ag 110m) .......1
Silver 111 (Ag 111) .......100
Sodium 22 (Na 22) .......10
Sodium 24 (Na 24) .......10
Strontium 85 (Sr 85) .......10
Strontium 89 (Sr 89) .......1
Strontium 90 (Sr 90) .......0.1
Strontium 91 (Sr 91) .......10
Strontium 92 (Sr 92) .......10
Sulphur 35 (S 35) .......100
Tantalum 182 (Ta 182) .......10
Technetium 96 (Tc 96) .......10
Technetium 97m (Tc 97m) .......100
Technetium 97 (Tc 97) .......100
Technetium 99m (Tc 99m) .......100
Technetium 99 (Tc 99) .......10
Tellurium 125m (Te 125m) .......10
Tellurium 127m (TE 127m) .......10
Tellurium 127 (Te 127) .......100
Tellurium 129m (Te 129m) .......10
Tellurium 129 (Te 129) .......100
Tellurium 131m (Te 131m) .......10
Tellurium 132 (Te 132) .......10
Terbium 160 (Tb 160) .......10
Thallium 200 (Tl 200) .......100
Thallium 201 (Tl 201) .......100
Thallium 202 (Ti 202) .......100
Thallium 204 (Tl 204) .......10
Thulium 170 (Tm 170) .......10
Thulium 171 (Tm 171) .......10
Tin 113 (Sn 113) .......10
Tin 125 (Sn 125) .......10
Tungsten 181 (W 181) .......10
Tungsten 185 (W 185) .......10
Tungsten 187 (W 187) .......100
Vanadium 48 (V 48) .......10
Xenon 131m (Xe 131m) .......1,000
Xenon 133 (Xe 133) .......100
Xenon 135 (Xe 135) .......100
Ytterbium 175 (Yb 175) .......100
Yttrium 90 (Y 90) .......10
Yttrium 91 (Y 91) .......10
Yttrium 92 (Y 92) .......100
Yttrium 93 (Y 93) .......100
Zinc 65 (Zn 65) .......10
Zinc 69 (Zn 69) .......1,000
Zinc 69m (Zn 69m) .......100
Zirconium 93 (Zr 93) .......10
Zirconium 95 (Zr 95) .......10
Zirconium 97 (Zr 97) .......10
Radioactive material other than alpha emitting radioactive material not listed above .......0.1

TABLE 3

GENERAL LICENSES

ITEMS, TERMS AND CONDITIONS

Item (a)-Certain quantities of radioactive material, devices and equipment.

(1) A general license is hereby issued to transfer, receive, acquire, own, possess and use radio- active material incorporated in the following devices or equipment which have been manufactured or imported, tested and labeled in accordance with the specifications contained in a license or permit from the commissioner, the State Department of Health, the New York City Department of Health, the United States Nuclear Regulatory Commission or any agreement state, which license or permit provides that such items may be distributed to persons under the general license provisions of Item (a) or its equivalent. Such devices or equipment are:

(1) (i) A device designed for use as a static eliminator and containing as a sealed source a total quantity of not more than 500 microcuries of Polonium 210.

(1) (ii) Any device designed for use in ionizing air and containing, as a sealed source, a total quantity of not more than 500 microcuries of Polonium 210 or 50 millicuries of Hydrogen 3.

(2) Terms and conditions. Every person in respect to certain quantities of radioactive material, devices and equipment shall comply with the following requirements:

(2) (i) Such person shall not by any method combine, increase or cause any combination or increase in the radioactivity of any device containing radioactive material, or administer externally or internally, or direct the administration of, any device to a human being for any purpose.

(2) (ii) Such person shall comply with the requirements of this Part (Rule), specifically sections 38.20, 38.25 and 38.28(h) of this Title.

Item (b)-Certain fixed measuring, gauging or controlling devices.

(1) A general license is hereby issued to own, receive, acquire, possess and use radioactive material when contained in any fixed device designed for use in detecting, measuring, gauging or controlling thickness, density, level interface location, radiation, leakage or qualitative or quantitative chemical composition, or designed for producing light or ionized atmosphere, when such devices are manufactured or imported in accordance with the specifications contained in a license or permit issued to the supplier by the commissioner, the State Department of Health, the New York City Department of Health, the United States Nuclear Regulatory Commission or any agreement state and authorizing distribution under the general license of this Item or its equivalent, provided that:

(1) (i) Such devices contain no more than one millicurie of gamma-emitting radioactive material, where gamma radiation is the emission of interest; and contain no more than one millicurie of strontium 90 or of any transuranic radionuclide.

(1) (ii) Such devices are labeled in accordance with the provisions of a license which authorizes the distribution of the devices.

(1) (iii) Such devices bear a durable label containing the following or a substantially similar statement which contains the information called for in the following statement:

"The receipt, possession, use and transfer of this device, Model __, Serial No. __, are subject to a general license or equivalent and regulations of the United States Nuclear Regulatory Commission or of a State with which the Nuclear Regulatory Commission has entered into an agreement for the exercise of regulatory authority. This label shall be maintained on the device in a legible condition. Removal of this label is prohibited.

Caution-Radioactive Material

(Name of Supplier)"

(The model, serial number and name of the supplier may be omitted from this label provided they are elsewhere specified in labeling affixed to the device. Devices licensed and distributed prior to the effective date of this Part [Rule]may bear labels previously authorized.)

(1) (iv) Such devices are installed on the premises of the general licensee by a person authorized to install such devices under a license or permit issued to the installer by the commissioner, the State Department of Health, the New York City Department of Health, the United States Nuclear Regulatory Commission or any agreement state, if a label affixed to the device at the time of receipt states that installation by a licensee is required. The requirement of this Item does not apply while devices are held in storage in the original shipping containers pending installation by a licensee.

(2) Terms and conditions. Every person under this general license shall comply with the following requirements:

(2) (i) Such person shall, upon receipt of a generally licensed device, register it with the commissioner on a form prescribed by him describing the type of such device obtained, the quantity and the type of radioactive material contained in such device, and such other information as the commissioner may require.

(2) (ii) No such person shall dispose of, by abandonment or otherwise, any such device except by transfer to a person who holds a license or permit to receive such device issued by the commissioner, the State Department of Health, the New York City Department of Health, the United States Nuclear Regulatory Commission or any agreement state, or in case the device remains in use at a particular location, the transferor shall give the transferee a copy of the requirements of this Item and any safety documents identified in the label on the device and, upon transfer, notify the commissioner indicating the registration number, manufacturer's name, model and serial number of device transferred, the name and address of the transferee's radiation safety officer.

(2) (iii) Such person assures that all labels affixed to the devices bearing the statement "Removal of This Label is Prohibited" are maintained on the devices and shall comply with all instructions contained in such labels as a condition of his/her general license.

(2) (iv) Such person shall cause the device to be tested for leakage of radioactive material at the time of installation of the device or replacement of the radioactive material, and thereafter at intervals that do not exceed six months, or at such longer intervals, not to exceed three years, as specified by the appropriate licensing agency and indicated in the required label except that any such device containing only Krypton 85 need not be tested for leakage, and devices containing only Hydrogen 3 need not be so tested for any purpose.

(2) (v) Such person shall cause each device to be tested for proper operation of the on-off mechanism and indicator, if any, at the time of installation, after replacement of the radioactive material, after any repair or servicing of the device, and at the time of each inventory required by subparagraph (vi) of this paragraph.

(2) (vi) Such person shall conduct, or have conducted, a periodic inventory of all devices possessed under this general license. Such inventory shall be conducted at intervals not to exceed six months and shall be documented in a record containing the identity of each device, its location, the leak test interval and date of last leak test of the device, and the results of tests required by subparagraph (v) of this paragraph.

(2) (vii) Such person shall cause each required test and all other servicing involving such radioactive material, its shielding or containment, to be conducted as specified in the instructions provided by the labels, or by a person who holds a license which authorizes him/her to manufacture, install or service the device. Such leak test shall be capable of detecting at least 0.005 microcuries of removable radioactivity. Upon detection of leakage of such devices in excess of 0.005 microcuries of removable radioactivity, the person under this general license shall promptly notify the commissioner in writing.

(2) (viii) Upon any indication of a possible failure of or damage to the shielding or containment of such radioactive material or an on-off mechanism and indicator, such person shall immediately notify the commissioner and shall suspend use of such device until it has been repaired, lawfully disposed of or accepted by the commissioner as in substantial compliance with this Part (Rule).

(2) (ix) Such person shall comply with the requirements specified in section 38.28(h) of this Part (Rule) and such other requirements as the commissioner may determine to be applicable but otherwise shall be exempt from the requirements of sections 38.16 through 38.28 of this Part (Rule).

Item (c)-Strontium 90 in ice detection devices.

(1) A general license is hereby issued to own, receive, possess, use and transfer Strontium 90 contained In any device designed for use in ice detection and containing a total quantity of not more than so microcuries of Strontium 90 provided that:

(1) (i) Each such device has been manufactured or imported in accordance with a license or permit issued to the supplier by the commissioner, the State Department of Health, the New York City Department of Health, the United States Nuclear Regulatory Commission or any agreement state and authorizing distribution under the general license of this Item or its equivalent.

(1) (ii) Such devices are labeled in accordance with the provisions of a license which authorizes the distribution of the devices.

(1) (iii) Such devices bear durable labels which include the radiation hazard symbol as specified in section 38.25 of this Part (Rule), a statement that the device contains Strontium 90 and the quantity thereof, instructions for disposal, and statements that the device may be possessed pursuant to a general license or equivalent, that the manufacturer or civil authorities shall be notified if the device is found, that removal of labeling is prohibited and that disassembly and that repair of the device may be performed only by a person holding a license to manufacture or service such devices.

(2) Terms and conditions. Every person in respect to ice detectors containing Strontium 90 shall comply with the following requirements:

(2) (i) Such person shall, upon occurrence of visually observable damage (such as a bend or crack or discoloration from overheating) to the device, discontinue use of the device until it has been inspected, tested for leakage and repaired by a person authorized to conduct such activities by a specific license or permit from the commissioner, the State Department of Health, the New York City Department of Health, the United States Nuclear Regulatory Commission or any agreement state, or shall dispose of the device in accordance with section 38.20 of this Part (Rule).

(2) (ii) Such person shall assure that all labels affixed to the device at the time of receipt, and that bear a statement prohibiting removal, are maintained on such device.

(2) (iii) Such person shall not assemble, disassemble or repair Strontium 90 in ice detection devices.

(2) (iv) Such person shall comply with the requirements of section 38.20 of this Part (Rule) and such other requirements as the commissioner may determine to be applicable to a particular device, but otherwise such person shall be exempt from the requirements of sections 38.16 through 38.28 of this Part (Rule).

Item (d)-Source material.

(1) A general license is hereby issued authorizing commercial and industrial firms, and research, educational and medical institutions in respect to the use and transfer of any source material in quantities not exceeding a total of 15 pounds at any one time, or a total of 150 pounds in any calendar year, for commercial, industrial, research and developmental purposes.

(2) Terms and conditions. Every person in respect to generally licensed quantities of source material shall comply with the requirements of section 38.20 of this Part (Rule) and other requirements as the commissioner may determine to be applicable, but otherwise such person shall be exempt from the requirements of sections 38.16 through 38.28 of this Part (Rule), except that:

(2) (i) This exemption shall not be deemed to apply to any such person who is also in possession of source material under a license or permit issued by the commissioner, the State Department of Health or the New York City Department of Health.

Item (e)-Luminous safety devices for use in aircraft.

(1) A general license is hereby issued for all persons in respect to Hydrogen 3 or Promethium 147 contained in luminous safety devices for use in aircraft, when each device contains not more than 10 curies of Hydrogen 3 or 300 millicuries of Promethium 147 and has been manufactured, assembled or imported in accordance with a license or permit issued by the commissioner, the State Department of Health, the New York City Department of Health, the United States Nuclear Regulatory Commission or any agreement state and authorizing distribution under the general license of this Item or equivalent. This exemption does not authorize the manufacture, assembly or repair of luminous safety devices containing Hydrogen 3 or Promethium 147. This exemption does not authorize the transfer, receipt, possession or use of Promethium 147 in instrument dials.

(2) Terms and conditions. Every person in respect to generally licensed luminous safety devices for use in aircraft shall comply with the requirements of section 38.20 of this Part (Rule) and other requirements as the commissioner may determine to be applicable, but otherwise such person shall be exempt from the requirements of sections 38.16 through 38.28 of this Part (Rule).

Item (f)-Americium 241 and Plutonium in the form of calibration or reference sources.

(1) A general license is hereby issued with respect to Americium 241 and Plutonium contained in the form of calibration or reference sources to those persons holding a license or permit issued by the commissioner, the State Department of Health or the New York City Department of Health authorizing the receipt, possession, use and transfer of radioactive materials or persons holding licenses issued by the United States Nuclear Regulatory Commission authorizing the receipt, possession, use and transfer of special nuclear material. Such sources must have been manufactured or imported, tested and labeled in accordance with a license or permit issued by the commissioner, the State Department of Health, the New York City Department of Health, the United States Nuclear Regulatory Commission or any agreement state, and authorizing the distribution under the general license of this Item or equivalent.

(2) Terms and conditions. Every person in respect to generally licensed Americium 241 or Plutonium calibration or reference sources shall comply with the following requirements:

(2) (i) Such person shall not possess at any one time, at any one location of storage or use, more than five microcuries of Americium 241 and five microcuries of Plutonium in the form of generally licensed sources.

(2) (ii) Such person shall not receive, possess, use or transfer any such source unless the source, or the storage container, shall have affixed thereto a label with the following statement or a substantially similar statement:

"The receipt, possession, use and transfer of this source, Model No. __, Serial No. __, are subject to general license or the equivalent and the regulations of the United States Nuclear Regulatory Commission or of a state with which the Nuclear Regulatory Commission has entered into an agreement for the exercise of regulatory authority. Do not remove this label. CAUTION-RADIOACTIVE MATERIAL-THIS SOURCE CONTAINS (Use name of material in source). DO NOT TOUCH RADIOACTIVE PORTION OF THIS SOURCE.

(Name of manufacturer or importer)"

(2) (iii) Such person shall not transfer, abandon or dispose of such source except by transfer to a person authorized to receive the source by a license or permit issued by the commissioner, the State Department of Health, the New York City Department of Health, the United States Nuclear Regulatory Commission or an agreement state.

(2) (iv) Such person shall store such source, except when the source is being used, in a closed container adequately designed and constructed to contain Americium 241 or Plutonium which might otherwise escape during storage.

(2) (v) Such person shall not use such source for any purpose other than the calibration of radiation detectors or the standardization of other sources.

(2) (vi) Such person shall comply with other applicable requirements of this Part (Rule).

Item (g)-Depleted uranium in certain industrial and commercial products or devices.

(1) A general license is hereby issued to receive, acquire, possess, use or transfer, depleted uranium contained in industrial and commercial products or devices for the purpose of providing a concentrated mass in a small volume of the product or device when the product or device is manufactured or imported in accordance with the specifications contained in a license or permit issued to the supplier by the commissioner, the State Department of Health, the New York City Department of Health, the United States Nuclear Regulatory Commission or any agreement state, and authorizing distribution under the general license of this Item or its equivalent, provided that:

(1) (i) Such product or devices are labeled in accordance with the provisions of a license which authorizes the distribution of the products or devices.

(1) (ii) Such products or devices are clearly impressed with the following wording clearly legible through any plating or other covering: "Depleted Uranium."

(2) Terms and conditions. Every person under this general license shall comply with the following requirements:

(2) (i) Such person shall, upon receipt of a general license device or product, register it with the commissioner on a form prescribed by him describing the radiation protection and control program to assure physical control over the depleted uranium products and devices and designed to prevent transfer to unauthorized persons and such other information as the commissioner may require.

(2) (ii) Such person shall not introduce such depleted uranium device or product, in any form, into any chemical, physical, or metallurgical treatment or process except a treatment or process for repair or restoration of any plating or other covering on the depleted uranium.

(2) (iii) No such person shall dispose of, by abandonment or otherwise, any such product or device except by transfer to a person who holds a license or permit to receive such product or device issued by the commissioner, the State Department of Health, the New York City Department of Health, the United States Nuclear Regulatory Commission or any agreement state or in case of transfer to a general licensee within the state a copy of this general license with its terms and conditions and a copy of the registration form prescribed by the commissioner to be completed by the transferee or in case of transfer to a nonagreement or other agreement State transferee, a copy of the appropriate regulation and registration form to be completed by the transferee.

(2) (iv) Within 30 days of any transfer, such person shall report in writing to the commissioner the name and address of the person receiving the depleted uranium product or device.

(2) (v) Such person shall comply with the requirements specified in section 38.28 of this Part (Rule) and such other requirements as the commissioner may determine to be applicable but otherwise such person shall be exempt from other requirements of this Part (Rule).

Item (h)-Radioactive Material for Certain In-Vitro Clinical or Laboratory Tests.

(1) A general license is hereby issued to own, receive, acquire, possess, transfer and use radioactive material as specified below for certain in-vitro clinical or laboratory tests by a physician, veterinarian, clinical laboratory or hospital. Such radioactive material shall be manufactured in accordance with a specific license issued by the commissioner, the State Department of Health, the New York City Department of Health, the United States Nuclear Regulatory Commission, any agreement state or any licensing nonagreement state, and such license shall authorize distribution under the general license of this Item or its equivalent, provided that:

(1) (i) Such radioactive material is in prepackaged units.

(1) (ii) Such radioactive material is limited for use in in-vitro clinical or laboratory tests not involving internal or external administration of radioactive material, or radiation therefrom, to human beings or animals, and is limited to the following radionuclides:

(1) (a) Carbon-14, in units not exceeding 10 microcuries each.

(1) (b) Cobalt-57, in units not exceeding 10 microcuries each.

(1) (c) Hydrogen-3 (Tritium), in units not exceeding 50 microcuries each.

(1) (d) Iodine-125, in units not exceeding 10 microcuries each.

(1) (e) Mock Iodine-125 reference or calibration sources, in units not exceeding 0.05 microcuries of Iodine-129 and 0.005 microcurie of Americium-241 each.

(1) (f) Iodine-131, in units not exceeding 10 microcuries each.

(1) (g) Iron-59, in units not exceeding 20 microcuries each.

(1) (h) Selenium-75, in units not exceeding 10 microcuries each.

(1) (iii) Such radioactive material in prepackaged units shall have a label affixed to the container or a leaflet or brochure in the package with the following statement or a substantially similar statement:

(1) (a) For agreement materials licensed by the United States Nuclear Regulatory Commission or agreement state, or nonagreement materials licensed by agreement states:

"This radioactive material may be received, acquired, possessed and used only by physicians, veterinarians, clinical laboratories or hospitals, and only for in- vitro clinical or laboratory tests not involving internal or external administration of the material, or the radiation therefrom, to human beings or animals. Its receipt, acquisition, possession, use and transfer are subject to the regulations and a general license of the United States Nuclear Regulatory Commission or of a State with which the commission has entered into an agreement for the exercise of regulatory authority.

(Name of manufacturer)"

(1) (b) For nonagreement materials licensed by nonagreement States:

"This radioactive material may be received, acquired, possessed and used only by physicians, veterinarians, clinical laboratories or hospitals and only for in- vitro clinical or laboratory tests not involving internal or external administration of the material or the radiation therefrom, to human beings or animals. Its receipt, acquisition, possession, use and transfer are subject to the regulations and a general license of a licensing nonagreement State or an agreement state.

(Name of manufacturer)"

(2) Terms and conditions. Every physician, veterinarian, clinical laboratory or hospital under this general license shall comply with the following requirements:

(2) (i) Such physician, veterinarian, clinical laboratory or hospital before receipt of radioactive material under this general license shall register with the commissioner, the State Department of Health or the New York City Department of Health on a form prescribed by the appropriate agency.

(2) (ii) Such physician, veterinarian, clinical laboratory or hospital shall not possess at any one time or at any one installation for storage or use a total amount of Cobalt-57, Iodine-125, Iodine-131, Iron-59 and Selenium-75, in excess of 200 microcuries.

(2) (iii) Such physician, veterinarian, clinical laboratory or hospital shall store the radioactive material, until used, in the original shipping container or in a container providing equivalent radiation protection.

(2) (iv) Such physician, veterinarian, clinical laboratory or hospital shall use the radioactive material only as specified in subparagraph (1)(ii) of this Item.

(2) (v) Such physician, veterinarian, clinical laboratory or hospital shall not transfer the radioactive material except in the unopened, labeled shipping container as received from supplier and except to a person authorized to receive it pursuant to a specific license issued by the commissioner, the State Department of Health, the New York City Department of Health, the United States Nuclear Regulatory Commission, any agreement state or any licensing nonagreement state (for naturally occurring or accelerator-produced radioactive material only).

(2) (vi) Such physician, veterinarian, clinical laboratory or hospital shall dispose of the mock Iodine-125 reference or calibration sources specified in subparagraph (1)(ii) of this Item only as specified in section 38.20 of this Part (Rule).

(2) (vii) Such physician, veterinarian, clinical laboratory or hospital shall keep his registration current by reporting any changes within 30 days after the effective date of such change to the commissioner, the State Department of Health or the New York City Department of Health as appropriate.

(2) (viii) Such physician, veterinarian, clinical laboratory or hospital shall comply with the requirements specified in sections 38.20 and 38.29(a) of this Part (Rule) for the mock Iodine-125 specified in subparagraph (ii) of this Item and such other requirements as the commissioner may determine to be applicable but otherwise shall be exempt from requirements of sections 38.16 through 38.28 of this Part (Rule).

TABLE 4

QUANTITIES OF LICENSED MATERIAL

Radionuclide

Microcuries

Hydrogen-3 .......1.000
Beryllium-7 .......1,000
Beryllium-10 .......1
Carbon-11 .......1,000
Carbon-14 .......1,000
Fluorine-18 .......1.000
Sodium-22 .......10
Sodium-24 .......100
Magnesium-28 .......100
Aluminum-26 .......10
Silicon-31 .......1.000
Silicon-32 .......1
Phosphorus-32 .......10
Phosphorus-33 .......100
Sulfur-35 .......100
Chlorine-36 .......10
Chlorine-38 .......1,000
Chlorine-39 .......1,000
Argon-39 .......1,000
Argon-41 .......1,000
Potassium-40 .......100
Potassium-42 .......1,000
Potassium-43 .......1,000
Potassium-44 .......1,000
Potassium-45 .......1,000
Iron-55 .......100
Iron-59 .......10
Iron-60 .......1
Cobalt-55 .......100
Cobalt-56 .......10
Cobalt-57 .......100
Cobalt-58m .......1,000
Cobalt-58 .......100
Cobalt-60m .......1,000
Cobalt-60 .......1
Cobalt-61 .......1,000
Cobalt-62m .......1,000
Nickel-56 .......100
Nickel-57 .......100
Nickel-59 .......100
Nickel-63 .......100
Nickel-65 .......1,000
Nickel-66 .......10
Copper-60 .......1,000
Copper-61 .......1,000
Copper-64 .......1,000
Copper-67 .......1,000
Zinc-62 .......100
Zinc-63 .......1,000
Zinc-65 .......10
Zinc-69m .......100
Zinc-69 .......1,000
Zinc-71m .......1,000
Selenium-73m .......1,000
Selenium-73 .......100
Calcium-41 .......100
Calcium-45 .......100
Calcium-47 .......100
Scandium-43 .......1,000
Scandium-44m .......100
Scandium-44 .......100
Scandium-46 .......10
Scandium-47 .......100
Scandium-48 .......100
Scandium-49 .......1,000
Titanium-44 .......1
Titanium-45 .......1,000
Vanadium-47 .......1.000
Vanadium-48 .......100
Vanadium-49 .......1,000
Chromium-48 .......1,000
Chromium-49 .......1,000
Chromium-51 .......1,000
Manganese-51 .......1,000
Manganese-52m .......1,000
Manganese-52 .......100
Manganese-53 .......1,000
Manganese-54 .......100
Manganese-56 .......1,000
Iron-52 .......100
Zinc-72 .......100
Gallium-65 .......1,000
Gallium-66 .......100
Gallium-67 .......1,000
Gallium-68 .......1,000
Gallium-70 .......1,000
Gallium-72 .......100
Gallium-73 .......1,000
Germanium-66 .......1,000
Germanium-67 .......1,000
Germanium-68 .......10
Germanium-69 .......1,000
Germanium-71 .......1,000
Germanium-75 .......1,000
Germanium-77 .......1,000
Germanium-78 .......1,000
Arsenic-69 .......1,000
Arsenic-70 .......1,000
Arsenic-71 .......100
Arsenic-72 .......100
Arsenic-73 .......100
Arsenic-74 .......100
Arsenic-76 .......100
Arsenic-77 .......100
Arsenic-78 .......1,000
Selenium-70 .......1,000
Krypton-87 .......1,000
Krypton-88 .......1,000
Selenium-75 .......100
Selenium-79 .......100
Selenium-81m .......1,000
Selenium-81 .......1,000
Selenium-83 .......1,000
Bromine-74m .......1,000
Bromine-74 .......1,000
Bromine-75 .......1,000
Bromine-76 .......100
Bromine-77 .......1,000
Bromine-80m .......1,000
Bromine-80 .......1,000
Bromine-82 .......100
Bromine-83 .......1,000
Bromine-84 .......1,000
Krypton-74 .......1,000
Krypton-76 .......1,000
Krypton-77 .......1,000
Krypton-79 .......1,000
Krypton-81 .......1,000
Krypton-83m .......1,000
Krypton-85m .......1,000
Krypton-85 .......1,000
Yttrium-88 .......10
Yttrium-90m .......1,000
Yttrium-90 .......10
Yttrium-91m .......1,000
Yttrium-91 .......10
Yttrium-92 .......100
Yttrium-93 .......100
Yttrium-94 .......1,000
Yttrium-95 .......1,000
Zirconium-86 .......100
Zirconium-88 .......10
Zirconium-89 .......100
Zirconium-93 .......1
Zirconium-95 .......10
Zirconium-97 .......100
Niobium-88 .......1,000
Niobium-89m (66 min) .......1,000
Niobium-89 (122 min) .......1,000
Niobium-90 .......100
Niobium-93m .......10
Niobium-94 .......1
Niobium-95m .......100
Niobium-95 .......100
Niobium-96 .......100
Niobium-97 .......1,000
Niobium-98 .......1,000
Molybdenum-90 .......100
Rhodium-102m .......10
Rhodium-102 .......10
Rhodium-103m .......1,000
Rhodium-105 .......100
Rhodium-106m .......1,000
Rhodium-107 .......1,000
Palladium-100 .......100
Palladium-101 .......1,000
Rubidium-79 .......1,000
Rubidium-81m .......1,000
Rubidium-81 .......1,000
Rubidium-82m .......1,000
Rubidium-83 .......100
Rubidium-84 .......100
Rubidium-86 .......100
Rubidium-87 .......100
Rubidium-88 .......1,000
Rubidium-89 .......1,000
Strontium-80 .......100
Strontium-81 .......1,000
Strontium-83 .......100
Strontium-85m .......1,000
Strontium-85 .......100
Strontium-87m .......1,000
Strontium-89 .......10
Strontium-90 .......0.1
Strontium-91 .......100
Strontium-92 .......100
Yttrium-86m .......1,000
Yttrium-86 .......100
Yttrium-87 .......100
Molybdenum-93m .......100
Molybdenum-93 .......10
Molybdenum-99 .......100
Molybdenum-101 .......1,000
Technetium-93m .......1,000
Technetium-93 .......1,000
Technetium-94m .......1,000
Technetium-94 .......1,000
Technetium-96m .......1,000
Technetium-96 .......100
Technetium-97m .......100
Technetium-97 .......1,000
Technetium-98 .......10
Technetium-99m .......1,000
Technetium-99 .......100
Technetium-101 .......1,000
Technetium-104 .......1,000
Ruthenium-94 .......1,000
Ruthenium-97 .......1,000
Ruthenium-103 .......100
Ruthenium-105 .......1,000
Ruthenium-106 .......1
Rhodium-99m .......1,000
Rhodium-99 .......100
Rhodium-100 .......100
Rhodium-101m .......1,000
Rhodium-101 .......10
Cadmium-104 .......1,000
Cadmium-107 .......1,000
Cadmium-109 .......1
Cadmium-113m .......0.1
Cadmium-113 .......100
Cadmium-115m .......10
Cadmium-115 .......100
Cadmium-117m .......1,000
Palladium-103 .......100
Palladium-107 .......10
Palladium-109 .......100
Silver-102 .......1,000
Silver-103 .......1,000
Silver-104m .......1,000
Silver-104 .......1,000
Silver-105 .......100
Silver-106m .......100
Silver-106 .......1,000
Silver-108m .......1
Silver-110m .......10
Silver-111 .......100
Silver-112 .......100
Silver-115 .......1,000
Tin-110 .......100
Tin-111 .......1,000
Tin-113 .......100
Tin-117m .......100
Tin-119m .......100
Tin-121m .......100
Tin-121 .......1,000
Tin-123m .......1,000
Tin-123 .......10
Tin-125 .......10
Tin-126 .......10
Tin-127 .......1,000
Tin-128 .......1,000
Antimony-115 .......1,000
Antimony-116m .......1,000
Antimony-116 .......1,000
Antimony-117 .......1,000
Antimony-118m .......1,000
Antimony-119 .......1,000
Antimony-120 (16 min.) .......1,000
Antimony-120 (5.76d) .......100
Antimony-122 .......100
Antimony-124m .......1,000
Antimony-124 .......10
Antimony-125 .......100
Iodine-121 .......1,000
Iodine-123 .......100
Iodine-124 .......10
Iodine-125 .......1
Iodine-126 .......1
Iodine-128 .......1,000
Iodine-129 .......1
Iodine-130 .......10
Iodine-131 .......1
Iodine-132m .......100
Iodine-132 .......100
Iodine-133 .......10
Iodine-134 .......1,000
Iodine-135 .......100
Xenon-120 .......1,000
Xenon-121 .......1,000
Xenon-122 .......1,000
Cadmium-117 .......1,000
Indium-109 .......1,000
Indium-110 (69.1 min) .......1,000
Indium-110 (4.9h) .......1,000
Indium-111 .......100
Indium-112 .......1,000
Indium-113m .......1,000
Indium-114m .......10
Indium-115m .......1,000
Indium-115 .......100
Indium-116m .......1,000
Indium-117m .......1,000
Indium-117 .......1,000
Indium-119m .......1,000
Antimony-126m .......1,000
Antimony-126 .......100
Antimony-127 .......100
Antimony-128 (10.4 min.) .......1,000
Antimony-128 (9.01h) .......100
Antimony-129 .......100
Antimony-130 .......1,000
Antimony-131 .......1,000
Tellurium-116 .......1,000
Tellurium-121m .......10
Tellurium-121 .......100
Tellurium-123m .......10
Tellurium-123 .......100
Tellurium-125m .......10
Tellurium-127m .......10
Tellurium-127 .......1,000
Tellurium-129m .......10
Tellurium-129 .......1,000
Tellurium-131m .......10
Tellurium-131 .......100
Tellurium-132 .......10
Tellurium-133m .......100
Tellurium-133 .......1,000
Tellurium-134 .......1,000
Iodine-120m .......1,000
Iodine-120 .......100
Cesium-125 .......1,000
Cesium-127 .......1,000
Cesium-129 .......1,000
Cesium-130 .......1,000
Cesium-131 .......1,000
Cesium-132 .......100
Cesium-134m .......1,000
Cesium-134 .......10
Cesium-135m .......1,000
Cesium-135 .......100
Cesium-136 .......10
Cesium-137 .......10
Cesium-138 .......1,000
Barium-126 .......1,000
Barium-128 .......100
Barium-131m .......100
Barium-131 .......100
Xenon-123 .......1,000
Xenon-125 .......1,000
Xenon-127 .......1,000
Xenon-129m .......1,000
Xenon-131m .......1,000
Xenon-133m .......1,000
Xenon-133 .......1,000
Xenon-135m .......1,000
Xenon-135 .......1,000
Xenon-138 .......1,000
Lanthanum-137 .......10
Lanthanum-138 .......100
Lanthanum-140 .......100
Lanthanum-141 .......100
Lanthanum-142 .......1,000
Lanthanum-143 .......1,000
Cerium-134 .......100
Cerium-135 .......100
Cerium-137m .......100
Cerium-137 .......1,000
Cerium-139 .......100
Cerium-141 .......100
Cerium-143 .......100
Cerium-144 .......1
Praesodymium-136 .......1,000
Praesodymium-137 .......1,000
Praesodymium-138m .......1,000
Praesodymium-139 .......1,000
Praesodymium-142m .......1,000
Praesodymium-142 .......100
Praesodymium-143 .......100
Praesodymium-144 .......1,000
Praesodymium-145 .......100
Praesodymium-147 .......1,000
Neodymium-136 .......1,000
Samarium-153 .......100
Samarium-155 .......1,000
Samarium-156 .......1,000
Europium-145 .......100
Europium-146 .......100
Europium-147 .......100
Europium-148 .......10
Europium-149 .......100
Europium-150 (12.62h) .......100
Europium-150 (34.2y) .......1
Europium-152m .......100
Europium-152 .......1
Europium-154 .......1
Europium-155 .......10
Europium-156 .......100
Europium-157 .......100
Europium-158 .......1,000
Gadolinium-145 .......1,000
Gadolinium-146 .......10
Gadolinium-147 .......100
Gadolinium-148 .......0.001
Gadolinium-149 .......100
Gadolinium-151 .......10
Barium-133m .......100
Barium-133 .......100
Barium-135m .......100
Barium-139 .......1,000
Barium-140 .......100
Barium-141 .......1,000
Barium-142 .......1,000
Lanthanum-131 .......1,000
Lanthanum-132 .......100
Lanthanum-135 .......1,000
Neodymium-138 .......100
Neodymium-139m .......1,000
Neodymium-139 .......1,000
Neodymium-141 .......1,000
Neodymium-147 .......100
Neodymium-149 .......1,000
Neodymium-151 .......1,000
Promethium-141 .......100
Promethium-143 .......100
Promethium-144 .......10
Promethium-145 .......10
Promethium-146 .......1
Promethium-147 .......10
Promethium-148m .......10
Promethium-148 .......10
Promethium-14g .......100
Promethium-150 .......1,000
Promethium-151 .......100
Samarium-141m .......1,000
Samarium-141 .......1,000
Samarium-142 .......1,000
Samarium-145 .......100
Samarium-146 .......1
Samarium-147 .......100
Samarium-151 .......10
Terbium-147 .......1,000
Terbium-149 .......100
Terbium-150 .......1,000
Terbium-151 .......100
Terbium-153 .......1,000
Terbium-154 .......100
Terbium-155 .......1,000
Terbium-156m (5.0h) .......1,000
Terbium-156m (24.4h) .......1,000
Terbium-156 .......100
Terbium-157 .......18
Terbium-158 .......1
Terbium-160 .......10
Terbium-161 .......100
Dysprosium-155 .......1,000
Dysprosium-157 .......1,000
Dysprosium-159 .......108
Dysprosium-165 .......1,000
Dysprosium-166 .......100
Holmium-155 .......100
Holmium-157 .......1,000
Holmium-159 .......1,000
Holmium-161 .......1,000
Gadolinium-152 .......100
Gadolinium-153 .......10
Gadolinium-159 .......10
Holmium-166m .......1
Holmium-166 .......100
Holmium-167 .......1,000
Erbium-161 .......1,000
Erbium-165 .......1,000
Erbium-169 .......100
Erbium-171 .......100
Erbium-172 .......100
Thulium-162 .......1,000
Thulium-166 .......100
Thulium-167 .......100
Thulium-170 .......10
Thulium-171 .......10
Thulium-172 .......100
Thulium-173 .......100
Thulium-175 .......1,000
Ytterbium-162 .......1,000
Ytterbium-166 .......100
Ytterbium-167 .......1,000
Ytterbium-169 .......100
Ytterbium-175 .......100
Ytterbium-177 .......1,000
Ytterbium-178 .......1,000
Lutetium-169 .......100
Lutetium-170 .......100
Lutetium-171 .......100
Tantalum-174 .......1,000
Tantalum-175 .......1,000
Tantalum-176 .......100
Tantalum-177 .......1,000
Tantalum-178 .......1,000
Tantalum-179 .......100
Tantalum-180m .......1,000
Tantalum-180 .......100
Tantalum-182m .......1,000
Tantalum-182 .......10
Tantalum-183 .......100
Tantalum-184 .......100
Tantalum-185 .......1,000
Tantalum-186 .......1,000
Tungsten-176 .......1,000
Tungsten-177 .......1,000
Tungsten-178 .......1,000
Tungsten-179 .......1,000
Tungsten-181 .......1,000
Tunten-185 .......100
Tungsten-187 .......100
Tungsten-188 .......10
Rhenium-177 .......1,000
Rhenium-178 .......1,000
Rhenium-181 .......1,000
Rhenium-182 (12.7h) .......1,000
Rhenium-182 (64.0h) .......100
Iridium-192m (1.4min.) .......10
Holmium-162m .......1,000
Holmium-162 .......1,000
Holmium-164m .......1,000
Holmium-164 .......1,000
Lutetium-172 .......100
Lutetium-173 .......10
Lutetium-174m .......10
Lutetium-174 .......10
Lutetium-176m .......1,000
Lutetium-176 .......100
Lutetium-177m .......10
Lutetium-177 .......100
Lutetium-178m .......1,000
Lutetium-178 .......1,000
Lutetium-179 .......1,000
Hafnium-170 .......100
Hafnium-172 .......1
Hafnium-173 .......1,000
Hafnium-175 .......100
Hafnium-177m .......1,000
Hafnium-178m .......0.1
Hafnium-179m .......10
Hafnium-180m .......1,000
Hafnium-181 .......10
Hafnium-182m .......1,000
Hafnium-182 .......0.1
Hafnium-183 .......1,000
Hafnium-184 .......100
Tantalum-172 .......1,000
Tantalum-173 .......1,000
Rhenium-184m .......10
Rhenium-184 .......100
Rhenium-186m .......10
Rhenium-186 .......100
Rhenium-187 .......1,000
Rhenium-188m .......1,000
Rhenium-188 .......100
Rhenium-190 .......100
Osmium-180 .......1,000
Osmium-181 .......1,000
Osmium-182 .......100
Osmium-185 .......100
Osmium-189m .......1,000
Osmium-191m .......1,000
Osmium-191 .......100
Osmium-193 .......100
Osmium-194 .......1
Iridium-182 .......1,000
Iridium-184 .......1,000
Iridium-185 .......1,000
Iridium-186 .......100
Iridium-187 .......1,000
Iridium-188 .......100
Iridium-189 .......100
Iridium-190m .......1,000
Iridium-190 .......100
Iridium-192 (73.8d) .......1
Mercury-193 .......1,000
Iridium-194m .......10
Iridium-194 .......100
Iridium-195m .......1,000
Iridium-195 .......1,000
Platinum-186 .......1,000
Platinum-188 .......100
Platinum-189 .......1,000
Platinum-191 .......100
Platinum-193m .......100
Platinum-193 .......1,000
Platinum-195m .......100
Platinum-197m .......1,000
Platinum-197 .......100
Platinum-199 .......1,000
Platinum-200 .......100
Gold-193 .......1,000
Gold-194 .......100
Gold-195 .......10
Gold-198m .......100
Gold-198 .......100
Gold-199 .......100
Gold-200m .......100
Gold-200 .......1,000
Gold-201 .......1,000
Mercury-193m .......100
Lead-203 .......1,000
Lead-205 .......100
Lead-209 .......1,000
Lead-210 .......0.01
Lead-211 .......100
Lead-212 .......1
Lead-214 .......100
Bismuth-200 .......1,000
Bismuth-201 .......1,000
Bismuth-202 .......1,000
Bismuth-203 .......100
Bismuth-205 .......100
Bismuth-206 .......100
Bismuth-207 .......10
Bismuth-210m .......0.1
Bismuth-210 .......1
Bismuth-212 .......10
Bismuth-213 .......10
Bismuth-214 .......100
Polonium-203 .......1,000
Polonium-205 .......1,000
Polonium-207 .......1,000
Polonium-210 .......0.1
Astatine-207 .......100
Astatine-211 .......10
Radon-220 .......1
Protactinium-231 .......0.001
Protactinium-232 .......1
Protactinium-233 .......100
Protactinium-234 .......100
Uranium-230 .......0.01
Uranium-231 .......100
Uranium-232 .......0.001
Mercury-194 .......1
Mercury-195m .......100
Mercury-195 .......1,000
Mercury-197m .......100
Mercury-197 .......1,000
Mercury-199m .......1,000
Mercury-203 .......100
Thallium-194m .......1,000
Thallium-194 .......1,000
Thallium-195 .......1,000
Thallium-197 .......1,000
Thallium-198m .......1,000
Thallium-198 .......1,000
Thallium-199 .......1,000
Thallium-200 .......1,000
Thallium-201 .......1,000
Thallium-202 .......100
Thallium-204 .......100
Lead-195m .......1,000
Lead-198 .......1,000
Lead-199 .......1,000
Lead-200 .......100
Lead-201 .......1,000
Lead-202m .......1,000
Lead-202 .......10
Radon-222 .......1
Prancium-222 .......100
Prancium-223 .......100
Radium-223 .......0.1
Radium-224 .......0.1
Radium-225 .......0.1
Radium-226 .......0.1
Radium-227 .......1,000
Radium-228 .......0.1
Actinium-224 .......1
Actinium-225 .......0.01
Actinium-226 .......0.1
Actinium-227 .......0.001
Actinium-228 .......1
Thorium-226 .......10
Thorium-227 .......0.01
Thorium-228 .......0.001
Thorium-229 .......0.001
Thorium-230 .......0.001
Thorium-231 .......100
Thorium-232 .......100
Thorium-234 .......10
Thorium-natural .......100
Protactinium-227 .......10
Protactinium-228 .......1
Protactinium-230 .......0.1
Plutonium-235 .......1,000
Plutonium-236 .......0.001
Plutonium-237 .......100
Plutonium-238 .......0.001
Plutonium-239 .......0.001
Plutonium-240 .......0.001
Plutonium-241 .......0.01
Uranium-233 .......0.001
Uranium-234 .......0.001
Uranium-235 .......0.001
Uranium-236 .......0.001
Uranium-237 .......100
Uranium-238 .......100
Uranium-239 .......1,000
Uranium-240 .......100
Uranium-natural .......100
Neptunium-232 .......100
Neptunium-233 .......1,000
Neptunium-234 .......100
Neptunium-235 .......100
Neptunium-236 (1.15×10 5 y) .......0.001
Neptunium-236 (22.5h) .......1
Neptunium-237 .......1.001
Neptunium-238 .......10
Neptunium-239 .......100
Neptunium-240 .......1,000
Plutonium-234 .......10
Curium-242 .......0.01
Curium-243 .......0.001
Curium-244 .......0.001
Curium-245 .......0.001
Curium-246 .......0.001
Curium-247 .......0.001
Curium-248 .......0.001
Curium-249m .......1,000
Berkelium-245 .......100
Berkelium-246 .......100
Berkelium-247 .......0.001
Berkelium-249 .......0.01
Berkelium-250 .......10
Californium-244 .......100
Californium-246 .......1
Californium-248 .......0.01
Caiifornium-249 .......0.001
Californium-250 .......0.001
Californium-251 .......0.001
Californium-252 .......0.001
Californium-253 .......0.1
Californium-254 .......0.001
Any alpha emitting radionuclide not listed above or mixtures of alpha emitters of unknown composition .......0.001
Plutonium-242 .......0.001
Plutonium-243 .......1,000
Plutonium-244 .......0.001
Plutonium-245 .......100
Americium-237 .......1,000
Americium-238 .......100
Americium-239 .......1,000
Americium-240 .......100
Americium-241 .......0.001
Americium-242m .......0.001
Americium-242 .......10
Americium-243 .......0.001
Americium-244m .......100
Americium-244 .......10
Americium-245 .......1,000
Americium-246m .......1,000
Americium-246 .......1,000
Curium-238 .......100
Curium-240 .......0.1
Curium-241 .......1
Einsteinium-250 .......100
Einsteinium-251 .......100
Einsteinium-253 .......0.1
Einsteinium-254m .......1
Einsteinium-254 .......0.01
Fermium-252 .......1
Fermium-253 .......1
Fermium-254 .......10
Fermium-255 .......1
Fermium-257 .......0.01
Mendelevium-257 .......10
Mendelevium-258 .......0.01

Radionuclide

Microcuries

Any radionuclide other than alpha emitting radionuclides not listed above, or mixtures of beta emitters of unknown composition ....... 0.01

Note: For purposes of sections 38.7 and 38.41, Table 1, Exemptions 28 and 29 of this Part (Rule) where there is involved a combination of radio-nuclides in known amounts, the limit for the combination shall be derived as follows: deter-mine, for each radionuclide in the combination, the ratio between the quantity present in the combination and the limit otherwise established for the specific radionuclide when not in combination. The sum of such ratios for all radio-nuclides in the combination may not exceed "1" (i.e., "unity").

TABLE 5

ACCEPTABLE SURFACE CONTAMINATION LEVELS

Nuclidea

Averageb c f

Maximumb d fRemovableb,c e f
U-nat, U-235, U-238, and associated decay products except Ra-226, Th-230, Ac-227, and Pa-2315,000 dpm alpha/100 cm215,000 dpm alpha/100 cm21,000 dpm alpha/100 cm2
Transuranics, Ra-223, Ra-224, Ra-226, Ra- 228, Th-nat, Th-228, Th-230, Th-232, U-232, Pa-231, Ac-227, Sr-90, I-125, I-126, I-129, I-131, I-1331,000 dpm/100 cm23,000 dpm/100 cm2200 dpm/100 cm2
Beta-gamma emitters (nuclides with decay modes other than alpha emission or spontaneous fission) except Sr-90 and others noted above.5,000 dpm beta, gamma/100 cm215,000 dpm beta, gamma/100 cm21,000 dpm beta, gamma/100 cm2

a Where surface contamination by both alpha and beta-gamma emitting nuclides exists, the limits established for alpha and beta-gamma emitting nuclides should apply independently.

b As used in this table, dpm (disintegrations per minute) means the rate of emission by radioactive material as determined by correcting the counts per minute observed by an appropriate detector for background, efficiency, and geometric factors associated with the instrumentation.

c Measurements of average contamination level should not be averaged over more than one square meter. For objects of less surface area, the average should be derived for each object.

d The maximum contamination level applies to an area of not more than 100 cm2.

e The amount of removable radioactive material per 100 cm2 of surface area should be determined by wiping that area with dry filter or soft absorbent paper, applying moderate pressure, and assessing the amount of radioactive material on the wipe with an appropriate instrument of known efficiency. When removable contamination on objects of less surface area is determined, the pertinent levels should be reduced proportionally and the entire surface should be wiped.

f The average and maximum radiation levels associated with surface contamination resulting from beta-gamma emitters should not exceed 0.2 mrad/hr at 1 centimeter and 1.0 mrad/hr at 1 centimeter, respectively, measured through not more than 7 mg/cm2 of total absorber.

TABLE 6

PROTECTION FACTORS FOR RESPIRATOR1

Protection Factors4

Tested and Certified Equipment

Description2Modes3Particulates, onlyParticulates, gases, vapor5National Institute for Occupational Safety and Health and Mine Safety and Health Administration tests for permissibility
I. AIR-PURIFYING RESPIRATORS6
Facepiece, half- mask7NP10 30 CFR 11, Subpart K*
Facepiece, fullNP50
Facepiece, half- mask full, or hoodPP1000
II. ATMOSPHERE-SUPPLYING RESPIRATORS
1. Air-line respirator
Facepiece, half- maskCF1000
Facepiece, half- maskD5
Facepiece, fullCF2000
Facepiece, fullD530 CFR 11, Subpart J*
Facepiece, fullPD2000
HoodCF8
SuitCF910
2. Self-contained breathing apparatus (SCBA)
Facepiece, fullD50
Facepiece, fullPD10,0001130 CFR 11, Subpart H*
Facepiece, fullRD50
Facepiece, fullRP5,00012
III. COMBINATION RESPIRATORS
Any combination of air-purifying and atmosphere- supplying respiratorsProtection factor for type and mode of operation as listed above 30 CFR 11, Sec. 11.63(b) *

*The documents referenced in this Part are available for review and copying at the New York State Department of Labor, State Campus, Building 12, Room 509, Albany, NY or the New York State Department of State, 162 Washington Ave., Albany, NY.

1 For use in the selection of respiratory protective equipment to be used only where the contaminants have been identified and the concentrations, or possible concentrations, are known.

2 Only for shaven faces and where nothing interferes with the seal of tight-fitting facepieces against the skin. Hoods and suits are expected.

3 The mode symbols are defined as follows:

CF = continuous flow

D = demand

NP = negative pressure, that is, negative phase during inhalation

PD =pressure demand, that is, always positive pressure

PP =positive pressure

RD = demand, recirculating or closed circuit

RP = pressure demand, recirculating or closed circuit

4(a) The protection factor is a measure of the degree of protection afforded by a respirator, defined as the ratio of the concentration of airborne radioactive material outside the respiratory protective equipment to that inside the equipment, usually inside the facepiece, under conditions of use. It is applied to the ambient airborne concentration to estimate the concentrations inhaled by the wearer according to the following formula:

Concentration inhaled = Ambient airborne concentration/Protection Factor

(b) The protection factors apply:

(i) Only for individuals trained in using respirators and wearing properly fitted respirators that are used and maintained under supervision in a well-planned respiratory protective program.

(ii) For air-purifying respirators only when high efficiency particulate filters, above 99.97 percent removal efficiency by thermally generated 0.3 1/4m dioctyl phthalate (DOP) test or equivalent, are used in atmospheres not deficient in oxygen and not containing radioactive gas or vapor respiratory hazards.

(iii) No adjustment is to be made for the use of sorbents against radioactive material in the form of gases or vapors.

(iv) For atmosphere-supplying respirators only when supplied with adequate respirable air. Respirable air shall be provided of the quality and quantity required in accordance with the National Institute for Occupational Safety and Health and the Mine Safety and Health Administration certification described in 30 CFR 11 . Oxygen and air shall not be used in the same apparatus.

5 Excluding radioactive contaminants that present an absorption or submersion hazard. For tritium oxide, approximately one-third of the intake occurs by absorption through the skin so that an overall protection factor of less than 2 is appropriate when atmosphere-supplying respirators are used to protect against tritium oxide. If the protection factor for respiratory protective equipment is 5, the effective protection factor for tritium is about 1.4; with protection factors of 10, the effective factor for tritium oxide is about 1.7; and with protection factors of 100 or more, the effective factor for tritium oxide is about 1.9. Air-purifying respirators are not suitable for protection against tritium oxide. See also footnote 9 concerning supplied-air suits.

6 Canisters and cartridges shall not be used beyond service-life limitations.

7 Under-chin type only. This type of respirator is not satisfactory for use where it might be possible, such as, if an accident or emergency were to occur, for the ambient airborne concentrations to reach instantaneous values greater than 10 times the pertinent values in Appendix A-13, Table I, column 3. This type of respirator is not suitable for protection against plutonium or other high-toxicity materials. The mask is to be tested for fit prior to use, each time it is donned.

8 (a) Equipment shall be operated in a manner that ensures that proper air flow-rates are maintained. A protection factor of no more than 1000 may be utilized for tested-and-certified supplied-air hoods when a minimum air flow of 6 cubic feet per minute (0.17 m 3/min) is maintained and calibrated air line pressure gauges or flow measuirng devices are used. A protection factor of up to 2000 may be used for tested and certified hoods only when the air flow is maintained at the manufacturer's recommended maximum rate for the equipment, this rate is greater than 6 cubic feet per minute (0.17 m 3/min) and calibrated air line pressure gauges or flow measuring devices are used.

(b) The design of the supplied-air hood or helmet, with a minimum flow of 6 cubic feet per minute (0.17 m 3/min) of air, may determine its overall efficiency and the protection it provides. For example, some hoods aspirate contaminated air into the beathing zone when the wearer works with hands-over-head. This aspiration may be overcome if a short cape-like extension to the hood is worn under a coat or overalls. Other limitations specified by the approval agency shall be considered before using a hood in certain types of atmospheres. See footnote 9.

9 Appropriate protection factors shall be determined, taking into account the design of the suit and its permeability to the contaminant under conditions of use. There shall be a standby rescue person equipped with a respirator or other apparatus appropriate for the potential hazards and communications equipment whenever supplied-air suits are used.

10No approval schedules are currently available for this equipment. Equipment is to be evaluated by testing or on the basis of reliable test information.

11 This type of respirator may provided greater protection and be used as an emergency device in unknown concentrations for protection against inhalation hazards. External radiation hazards and other limitations to permitted exposure, such as skin absorption, must be taken into account in such circumstances.

12 Quantitative fit testing shall be performed on each individual, and no more than 0.02 percent leakage is allowed with this type of apparatus. Perceptible outward leakage of gas from this or any positive pressure self-contained breathing apparatus is unacceptable because service life will be reduced substantially. Special training in the use of this type of apparatus shall be provided to the wearer.

Note 1: Protection factors for respirators approved by the U.S. Bureau of Mines and the National Institute for Occupational Safety and Health, according to applicable approvals for respirators for type and mode of use to protect against airborne radionuclides, may be used to the extent that they do not exceed the protection factors listed in this table. The protection factors listed in this table may not be appropriate to circumstances where chemical or other respiratory hazards exist in addition to radioactive hazards. The selection and use of respirators for such circumstances should take into account applicable approvals of the U.S. Bureau of Mines and the National Institute for Occupational Safety and Health.

Note 2: Radioactive contaminants, for which the concentration values in Appendix A-13, Table I, column 3 are based on internal dose due to inhalation, may present external exposure hazards at higher concentrations. Under these circumstances, limitations on occupancy may have to be governed by external dose limits.

TABLE 7

QUANTITIES OF RADIOACTIVE MATERIALS REQUIRING CONSIDERATION OF THE NEED FOR AN EMERGENCY PLAN FOR RESPONDING TO A RELEASE

Radioactive Material1

Release Fraction

Quantity (Curies)

Actinium-228.0014,000
Americium-241.0012
Americium-242.0012
Americium-243.0012
Antimony-124.014,000
Antimony-126.016,000
Barium-133.0110,000
Barium-140.0130,000
Bismuth-207.015,000
Bismuth-210.01600
Cadmium-109.011,000
Cadmium-113.0180
Calcium-45.0120,000
Californium-252.0019(20 mg)
Carbon-14.0150,000
(NonCO)
Cerium-141.0110,000
Cerium-144.01300
Cesium-134.012,000
Cesium-137.013,000
Chlorine-36.5100
Chromium-51.01300,000
Cobalt-60.0015,000
Copper-64.01200,000
Curium-242.00160
Curium-243.0013
Curium-244.0014
Curium-245.0012
Europium-152.01500
Europium-154.01400
Europium-155.013,000
Germanium-68.012,000
Gadolinium-153.015,000
Gold-198.0130,000
Hafnium-172.01400
Hafnium-181.017,000
Holmium-166m.01100
Hydrogen-3.520,000
Iodine-125.510
Iodine-131.510
Indium-114m.011,000
Iridium-192.00140,000
Iron-55.0140,000
Iron-59.017,000
Krypton-851.06,000,000
Lead-210.018
Manganese-56.0160,000
Mercury-203.0110,000
Molybdednum-99.0130,000
Neptunium-237.0012
Nickel-63.0120,000
Niobium-94.01300
Phosphorus-32.5100
Phosphorus-33.51,000
Polonium-210.0110
Potassium-42.019,000
Promethium-145.014,000
Promethium-147.014,000
Ruthenium-106.01200
Samarium-151.014,000
Scandium-46.013,000
Selenium-75.0110,000
Silver-110m.011,000
Sodium-22.019,000
Sodium-24.0110,000
Strontium-89.013,000
Strontium-90.0190
Sulfur-35.5900
Technetium-99.0110,000
Technetium-99m.01400,000
Tellurium-127m.015,000
Tellurium-129m.015,000
Terbium-160.014,000
Thulium-170.014,000
Tin-113.0110,000
Tin-123.013,000
Tin-126.011,000
Titanium-44.01100
Vanadium-48.017,000
Xenon-1331.0900,000
Yttrium-91.012,000
Zinc-65.015,000
Zirconium-93.01400
Zirconium-95.015,000
Any other beta-gamma emitter.0110,000
Mixed fission products.011,000
Mixed corrosion products.0110,000
Contaminated equipment beta-gamma.00110,000
Irradiated material, any form other than solid noncombustible.011,000
Irradiated material, solid noncombustible.00110,000
Mixed radioactive waste, beta-gamma.011,000
Packaged mixed waste, beta-gamma2.00110,000
Any other alpha emitter.0012
Contaminated equipment, alpha.000120
Packaged waste, alpha2.000120
Combinations of radioactive materials listed above1

1 For combinations of radioactive materials, consideration of the need for an emergency plan is required if the sum of the ratios of each quantity of each radioactive material authorized to the quantity listed for that material in Table 7 exceeds one.

2 Waste packaged in Type B containers does not require an emergency plan.

TABLE 8

APPROVALS

Item (a)-Reagent kits. Reagent kits for use with certain radio pharmaceuticals by Group III medical licensees shall be approved by the commissioner.

Note: Group III medical licenses authorize the use of generators and approved reagent kits for the preparation and use of radio pharmaceuticals for diagnostic uses.

TABLE 9

EXEMPT CONCENTRATIONS

Element(atomic number)

Radionuclide

Column I Gas concentration (µCi/ml (1))

Column II Liquid and solid concentration (µCi/ml (2))

Antimony (51)Sb 1223 × 10 - (4)
Sb 1242 × 10 - (4)
Sb 1251 × 10 - (3)
Argon (18)A-371 × 10 - (3)
A 414 × 10 - (7)
Arsenic (33)As 735 × 10 - (3)
As 745 × 10 - (4)
As 762 × 10 - (4)
As 778 × 10 - (4)
Barium (56)Ba 1312 × 10 - (3)
Ba 1403 × 10 - (4)
Beryllium (4)Be 72 × 10 - (2)
Bismuth (83)Bi 2064 × 10 - (4)
Bromine (35)Br 824 × 10 - (7)3 × 10 - (3)
Cadmium (48)Cd 1092 × 10 - (3)
Cd 115m3 × 10 - (4)
Cd 1153 × 10 - (4)
Calcium (20)Ca 459 × 10 - (5)
Ca 475 × 10 - (4)
Carbon (6)C 14l × 10 - (6)8 × 10 - (5)
Cerium (58)Ce 1419 × 10 - (4)
Ce 1434 × 10 - (4)
Ce 144l × 10 - (4)
Cesium (55)Cs 1312 × 10 - (2)
Cs 134m6 × 10 - (2)
Cs 1349 × 10 - (5)
Chlorine (17)Cl 389 × 10 - (7)4 × 10 - (3)
Chromium (24)Cr 512 × 10 - (2)
Cobalt (27)Co 575 × 10 - (3)
Co 58l × 10 - (3)
Co 605 × 10 - (4)
Copper (29)Cu 643 × 10 - (3)
Dysprosium (66)Dy 1654 × 10 - (2)
Dy 1664 × 10 - (4)
Erbium (68)Er 1699 × 10 - (4)
Er 171l × 10 - (3)
Europium (63)Eu 1526 × 10 - (4)
(T/2 = 9.2 Hrs.)
Eu 1552 × 10 - (2)
Fluorine (9)F 182 × 10 - (6)8 × 10 - (3)
Gadolinium (64)Gd 1532 × 10 - (3)
Gd 1598 × 10 - (4)
Gallium (31)Ga 724 × 10 - (4)
Germanium (32)Ge 712 × 10 - (2)
Gold (79)Au 1962 × 10 - (3)
Au 1985 × 10 - (4)
Au 1992 × 10 - (3)
Hafnium (72)Hf 1817 × 10 - (4)
Hydrogen (1)H 35 × 10 - (6)3 × 10 - (2)
Indium (49)In 113ml × 10 - (2)
In 114m2 × 10 - (4)
Iodine (53)I 1263 × 10 - (9)2 × 10 - (5)
I 1312 × 10 - (5)
I 1326 × 10 - (4)
I 1337 × 10 - (5)
I 134l × 10 - (3)
Iridium (77)Ir 1902 × 10 - (3)
Ir 1924 × 10 - (4)
Ir 1943 × 10 - (4)
Iron (26)Fe 558 × 10 - (3)
Fe 596 × 10 - (6)
Krypton (36)Kr 85ml × 10 - (6)
Kr 85
Lanthanum (57)La 1402 × 10 - (4)
Lead (82)Pb 2034 × 10 - (3)
Lutetium (71)Lu 177l × 10 - (3)
Manganese (25)Mn 523 × 10 - (4)
Mn 54l × 10 - (3)
Mn 56l × 10 - (3)
Mercury (80)Hg 197m2 × 10 - (3)
Hg 1973 × 10 - (3)
Hg 2032 × 10 - (4)
Molybdenum (42)Mo 992 × 10 - (3)
Neodymium (60)Nd 1476 × 10 - (4)
Nd 1493 × 10 - (4)
Nickel (28)Ni 65l × 10 - (3)
Niobium (Columbium) (41)Nb 95l × 10 - (3)
Nb 979 × 10 - (3)
Osmium (76)Os 1857 × 10 - (4)
Os 191m3 × 10 - (2)
Os 1912 × 10 - (3)
Os 1936 × 10 - (4)
Palladium (46)Pd 1033 × 10 - (3)
Pd 1099 × 10 - (4)
Phosphorus (15)P 322 × 10 - (4)
Platinum (78)Pt 1911 × 10 - (3)
Pt 193m1 × 10 - (2)
Pt 197m1 × 10 - (2)
Pt 1971 × 10 - (8)
Polonium (84)Po 2102 × 10 - (10)7 × 10 - (6)
Potassium (19)K 423 × 10 - (3)
Praseodymium (59)Pr 1423 × 10 - (4)
Pr 1435 × 10 - (4)
Promethium (61)Pm 1472 × 10 - (3)
Pm 1494 × 10 - (4)
Radium (88)Ra 2261 × 10 - (11)1 × 10 - (7)
Ra 2283 × 10 - (7)
Rhenium (75)Re 1836 × 10 - (8)
Re 1869 × 10 - (4)
Re 1886 × 10 - (4)
Rhodium (45)Rh 103m1 × 10 - (2)
Rh 1051 × 10 - (3)
Rubidium (37)Rb 867 × 10 - (4)
Ruthenium (44)Ru 974 × 10 - (2)
Ru 1038 × 10 - (4)
Ru 1051 × 10 - (2)
Ru 1061 × 10 - (4)
Samarium (62)Sm 1528 × 10 - (4)
Scandium (21)Sc 464 × 10 - (4)
Sc 479 × 10 - (4)
Sc 483 × 10 - (4)
Selenium (34)Se 753 × 10 - (3)
Silicon (14)Si 319 × 10 - (3)
Silver (47)Ag 1051 × 10 - (3)
Ag 110m3 × 10 - (4)
Ag 1114 × 10 - (4)
Sodium (11)Na 242 × 10 - (3)
Strontium (38)Sr 851 × 10 - (2)
Sr 891 × 10 - (4)
Sr 917 × 10 - (4)
Sr 927 × 10 - (4)
Sulfur (16)S 359 × 10 - (3)6 × 10 - (4)
Tantalum (73)Ta 1824 × 10 - (4)
Technetium (52)Tc 96m1 × 10 - (1)
Tc 961 × 10 - (3)
Tellurium (52)Te 125m2 × 10 - (3)
Te 127m6 × 10 - (4)
Te 1273 × 10 - (3)
Te 129m3 × 10 - (4)
Te 131m6 × 10 - (4)
Te 1323 × 10 - (4)
Terbium (65)Tb 1604 × 10 - (4)
Thallium (81)Tl 2004 × 10 - (3)
Tl 2013 × 10 - (3)
Tl 2021 × 10 - (3)
Tl 2041 × 10 - (3)
Thulium (69)Tm 1705 × 10 - (4)
Tm 1715 × 10 - (3)
Tin (50)Sn 1139 × 10 - (4)
Sn 1252 × 10 - (4)
Tungsten (Wolfram) (74)W 1814 × 10 - (3)
W 1877 × 10 - (4)
Vanadium (23)V 483 × 10 - (4)
Xenon (54)Xe 131m4 × 10 - (6)
Xe 1333 × 10 - (6)
Xe 1351 × 10 - (6)
Ytterbium (70)Yb 1751 × 10 - (3)
Yttrium (39)Y 902 × 10 - (4)
Y 91m3 × 10 - (2)
Y 913 × 10 - (4)
Y 926 × 10 - (4)
Y 933 × 10 - (4)
Zinc (30)Zn 651 × 10 - (3)
Zn 69m7 × 10 - (4)
Zn 692 × 10 - (2)
Zirconium (40)Zr 956 × 10 - (4)
Zr 972 × 10 - (4)
Beta and/or gamma emitting radioactive material not listed above with half-life less than 3 years.1 × 10 - (10)1 × 10 - (6)
Alpha emitting radioactive material (other than special nuclear material) not listed above.1 × 10 - (12)1 × 10 - (8)

(1) Values are given only for those radionuclides normally used as gases.

(2) uc/gm for solids.

Note 1:

Many radionuclides disintegrate into daughter products which are also radioactive. In expressing the concentations in Table 2 the activity stated is that of the parent radionuclide and takes into account the radioactive daughter products.

Note 2:

For purposes of Table 1, subdivision (a), where there is present a combination of radionuclides, the limit for the combination shall be derived as follows: Determine for each radionuclide present the radio between the concentration of the radionuclide in the combination and the exempt concentration lised in Table 2. The sum of such ratios shall not exceed unity.

Example.

(1) Values are given only for those radionuclides normally used as gases.

(2) uc/gm for solids.

Concentration of Radionuclide A in Combination/Exempt concentration of Radionuclide A + Concentration of Radionuclide B in Combination/Exempt concentration of Radionuclide B < =1

Footnotes

a Where surface contamination by both alpha and beta-gamma emitting nuclides exists, the limits established for alpha and beta-gamma emitting nuclides should apply independently.

b As used in this table, dpm (disintegrations per minute) means the rate of emission by radioactive material as determined by correcting the counts per minute observed by an appropriate detector for background, efficiency, and geometric factors associated with the instrumentation.

c Measurements of average contamination level should not be averaged over more than one square meter. For objects of less surface area, the average should be derived for each object.

d The maximum contamination level applies to an area of not more than 100 cm2.

e The amount of removable radioactive material per 100 cm2 of surface area should be determined by wiping that area with dry filter or soft absorbent paper, applying moderate pressure, and assessing the amount of radioactive material on the wipe with an appropriate instrument of known efficiency. When removable contamination on objects of less surface area is determined, the pertinent levels should be reduced proportionally and the entire surface should be wiped.

f The average and maximum radiation levels associated with surface contamination resulting from beta-gamma emitters should not exceed 0.2 mrad/hr at 1 centimeter and 1.0 mrad/hr at 1 centimeter, respectively, measured through not more than 7 mg/cm2 of total absorber.

1 For combinations of radioactive materials, consideration of the need for an emergency plan is required if the sum of the ratios of each quantity of each radioactive material authorized to the quantity listed for that material in Table 7 exceeds one.

2 Waste packaged in Type B containers does not require an emergency plan.

N.Y. Comp. Codes R. & Regs. tit. 12, Appendices, app A-10