Current through Register Vol. 35, No. 23, December 10, 2024
Section 7.8.3.79 - ACCESS REQUIREMENTS FOR THE DISABLED IN NEW FACILITIESAccessibility to the disabled must be provided in all new facilities and includes, at a minimum, the following:
A. Main entry into the facility must be level or incorporate a ramp to allow for wheelchair access.B. Building layout must allow for access to main living area and dining area.C. At least one (1) bedroom must have a door clearance of 32 inches.D. At least one (1) toilet/bathing facility must provide a 60-inch diameter turning radius.E. If ramps are used, the slope of each ramp must provide at least a 12-inch horizontal run for each inch of vertical rise.F. Ramps exceeding a six-inch rise must be provided with handrails.G. Additional access requirements may apply depending upon the size and complexity of the facility.N.M. Admin. Code § 7.8.3.79
7.8.3.79 NMAC - N, 05/15/01