Current through Register Vol. 35, No. 23, December 10, 2024
A. All exit doors must have a minimum width of 36 inches.B. All sleeping room doors must have at least one and three quarter inches bonded solid core, with a minimum width of 32 inches.C. All doors to toilet and bathing facilities must have a minimum width of 24 inches.D. Locks on doors to toilets must be of a type that the lock can be released from the outside.E. Exit doors leading to the outside of a facility with a capacity of ten or more children must open outward.F. Exit doors leading to the outside of a facility must be provided with a night latch, dead bolt or security chain, provided such devices open from the inside without the use of a key or tool and are mounted at a height not to exceed 48 inches above the finished floor.G. Sleeping room doors for non-mobile children must be at least one and three quarter inches bonded solid core, with a minimum width of 44 inches.H. Each sleeping room housing non-mobile children must have a 44-inch exit door leading directly to the outside.N.M. Admin. Code § 7.8.3.74
7.8.3.74 NMAC - N, 05/15/01