Current through Register Vol. 35, No. 23, December 10, 2024
Section 7.20.12.82 - ACCESS REQUIREMENTS FOR DISABLED IN NEW FACILITIESA. Accessibility to the disabled is provided in all new facilities and will include the following: (1) main entry into the facility is level or has a ramp to allow for wheelchair access;(2) building layout allows for access to main living area and dining area;(3) access to at least one bedroom is required to have a door clearance of 32 inches; the toilet/bathing unit also provides a 60-inch diameter clear space (turning radius);(4) if ramps are provided to the building, the slope of each ramp is at least a 12-inch horizontal run for each inch of vertical rise;(5) ramps exceeding a six-inch rise are provided with handrails.B. Requirements contained herein are minimum and additional disability requirements apply depending on the size and complexity of the facility.N.M. Admin. Code § 7.20.12.82
1/1/99; 7.20.12.82 NMAC - Rn, 7 NMAC 20.12.82, 02/28/05