Section 20.3.15.1528 - REPORTSA. In addition to the reporting requirements in other parts these regulations (20.3 NMAC), the licensee shall report the following events, if not reported under other parts these regulations (20.3 NMAC):(1) source stuck in an unshielded position;(2) any fire or explosion in a radiation room;(3) damage to the source racks;(4) failure of the cable or drive mechanism used to move the source racks;(5) inoperability of the access control system;(6) detection of radiation source by the product exit monitor;(7) detection of radioactive contamination attributable to licensed radioactive material;(8) structural damage to the pool liner or walls;(9) abnormal water loss or leakage from the source storage pool; and(10) pool water conductivity exceeding 100 microsiemens per centimeter.B. The report must include a telephone report within 24 hours as described in Paragraph (1) of Subsection C of 20.3.3.325 NMAC, and a written report within 30 days as described in Paragraph (2) of Subsection C of 20.3.3.325 NMAC.N.M. Admin. Code § 20.3.15.1528